• Title/Summary/Keyword: Incheon Airport

Search Result 390, Processing Time 0.028 seconds

A Study on the application of Roof Truss Sliding Method in the Incheon International Amort Transportation Center - Great Hall (Roof Truss Sliding 공법 적용사례 연구 인천국제공항 교통센터 - Great Hall)

  • Lee Dong-Ryul
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.214-221
    • /
    • 2001
  • The Great Hall of Incheon International Airport Transportation Center has irregular curved roof structure. The structure consists of 13 main steel trusses. (the longest span of 162m, 480ton) The total weight of the truss is 6,300ton and the whole truss is made of 9,600 pieces which has the joint connected to maximum 13 different parts at one point and Roof Truss is supported by 12 Fabric Foundation. Considering the economical efficiency and the schedule, the Sliding Construction Method was used other than conventional erection method. The roof truss structure was divided into two blocks, 3,550ton and 2,700ton, each block was pre-erected on the Giant Sleigh off the site and was pulled 181m by using Tandem Pulling Jack and Strand to be set in place.

  • PDF

A Study on the Determination of Depth of Soft Ground by Cone Resistance (피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구)

  • 신윤섭;김민철;김연정;김영웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

Vibration Characteristic of Full Weight Case Maglev Vehicle Running at Switching System (만차 조건 자기부상열차의 분기기 구간 주행 시 진동 특성)

  • Shin, Hyeon-Jae;Lee, Jong-Min;Kim, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.678-684
    • /
    • 2011
  • In 2013, Korea will become the world's second country to operate the urban Maglev system with the inauguration of demonstration line at Incheon International Airport. A prototype Maglev is under the test at KIMM's(Korea Institute of Machinery & Materials, Daejeon) track. This Maglev is an EMS(Electromagnetic suspension)-type vehicle of controlled $8{\pm}3mm$ air gap. The air gap between electromagnet and the guiderail in an EMS-type Maglev must be maintained within an allowable deviation by controlling the magnet. The air gap response is strongly dependent on the structural characteristics of the elevated guideway. For this reason, the interaction between the vehicle with electromagnets and the elevated guideway must be understood to ensure safe running. The purpose of this paper is to compare vibration characteristics of the vehicle on the switching system and other sections when the full weight condition of urban maglev vehicle that 26.5 tons per car(empty car weight 19 tons + passenger condition 7.5 tons), is applied. Through such results, Maglev vehicles and switching system can be established and the levitation stability can be improved.

  • PDF

Development and Performance Test Results of a Segmented Scissors Type Switch for the Urban Maglev (도시형 자기부상열차 시저스분기기 개발현황과 성능시험결과)

  • Lee, Jong-Min;Park, Doh-Young;Han, Hyung-Suk;Kim, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3180-3186
    • /
    • 2011
  • A segmented scissors type switch has been developed for the urban transit maglev demonstration line to be commercialized near Incheon International Airport in 2013. Based on the design of the previous segmented 3-way switch, the scissors switch is composed of four segmented 2-way switches up/down and left/right and a turn table in the mid point. The main function of the scissors switch is to change the running direction of the train at end terminals. The developed scissors switch is planned to be installed in front of the 102 station, which has a side platform, of the demonstration line. The total length of the switch is 65m and the distance between the up and down track centerlines is 6m. The 2-way switches and turn table are made of steel box type beams, and have their own driving unit, locking unit, control unit, levitation and propulsion rails, and so on. Installed in the factory, a 100,000-cycle continuous operation test was carried out after manual and automatic test operations. The applicapability of the developed switch was verified through the measurements of the linearity of the track after repetitive operations, the mechanical operation noise, the load of the main driving motor, the safety of the control panel, the natural frequency of the girder, the deformation of the girder, and so on.

  • PDF

A Study on Basic Data for the Architectural Plan of Small and medium-sized Local Airports - Focused on Analysis of Airline Demands and the Actual Conditions of Passenger Facilities - (중소형 지방공항의 건축계획을 위한 기초자료 연구 -항공수요 및 여객이용시설 실태 분석을 중심으로-)

  • Park, Chung-Keun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.3
    • /
    • pp.9-18
    • /
    • 2014
  • Small and medium-sized local airports have suffered from chronic operating deficits due to many factors except for large airports in Incheon, Gimpo, Jeju and Gimhae. These small and medium-sized local airports have currently been degraded to inefficient airports handling the significantly lower airline demand than their carrying capacities. In this context, this study conducted a survey on the actual conditions of the airline demand in small and medium-sized local airports for the last 10 years after the opening of the Korea Train eXpress and investigated the causes and actual conditions of an increase and a decrease in the airline demand. In addition, it analyzed the functionality, convenience and economic feasibility, competition elements in comparison with other means of transportation, and the actual competitive conditions of local airports. It investigated facility improvements through a field visit for local airports and analyzed the performance rate of passenger demands and the use rate of terminal facilities according to a change in the airline demand. This study aimed to provide basic data in the architectural planning field, needed to establish a plan for the airport revitalization of local airports with the results of an analysis on the actual conditions of small and medium-sized local airports.

Species Identification and Tree-Ring Dating of the Lotus Pedestal of Amitabha Statue at Ssangbong-Temple in Hwasun, Korea (화순 쌍봉사 극락전 아미타불 연화좌대의 수종 및 연륜연대 분석)

  • Kim, Yo-Jung;Son, Byung-Hwa;Oh, Jung-Ae;Jo, Tae-Gun;Choi, Sun-Il;Park, Won-Kyu
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.1
    • /
    • pp.95-102
    • /
    • 2012
  • The objective of this study was to conduct the species identification and tree-ring dating of Lotus Pedestal of the Amitabha Statue at Ssangbong-Temple in Hwasun. The six wood blocks used for the Lotus Pedestal were hard pines (Pinus spp.; diploxilon) except one piece which was ginkgo (Ginkgo biloba L.). The lotus leaves surrounding the pedestal body were also made of ginkgo. Tree-ring patterns of 3 blocks were synchronized and a 133 years chronology was made. The chronology was crossdated well with the master chronology of Japanese red pine in South Korea. It dated back to A. D. 1551~1683, i.e. the last ring dated A. D. 1683. Through the estimation of the number of sapwood rings removed during carving, the felling year was calculated A. D. $1704{\pm}10$. The calligraphic writing on the Pedestal indicated that this statue was made in A. D. 1694. Therefore, the accuracy of the tree-ring dating has been proven.

  • PDF

Development and Validation of the Coupled System of Unified Model (UM) and PArameterized FOG (PAFOG) (기상청 현업 모형(UM)과 1차원 난류모형(PAFOG)의 접합시스템 개발 및 검증)

  • Kim, Wonheung;Yum, Seong Soo
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.149-154
    • /
    • 2015
  • As an attempt to improve fog predictability at Incheon International Airport (IIA) we couple the 3D weather forecasting model currently operational in Korea Meteorological Administration (regional Unified Model, UM_RE) with a 1D turbulence model (PAFOG). The coupling is done by extracting the meteorological data from the 3D model and properly inserting them in the PAFOG model as initial conditions and external forcing. The initial conditions include surface temperature, 2 m temperature and dew point temperature, geostrophic wind at 850 hPa and vertical profiles of temperature and dew point temperature. Moisture and temperature advections are included as external forcing and updated every hr. To validate the performance of the coupled system, simulation results of the coupled system are compared to those of the 3D model alone for the 22 sea fog cases observed over the Yellow Sea. Three statistical indices, i.e., Root Mean Square Error (RMSE), linear correlation coefficient (R) and Critical Success Index (CSI), are examined, and they all indicate that the coupled system performs better than the 3D model alone. These are certainly promising results but more improvement is required before the coupled system can actually be used as an operational fog forecasting model. For the RMSE, R, and CSI values for the coupled system are still not good enough for operational fog forecast.

Life cycle cost analysis and smart operation mode of ground source heat pump system

  • Yoon, Seok;Lee, Seung-Rae
    • Smart Structures and Systems
    • /
    • v.16 no.4
    • /
    • pp.743-758
    • /
    • 2015
  • This paper presents an advanced life cycle cost (LCC) analysis of a ground source heat pump (GSHP) system and suggests a smart operation mode with a thermal performance test (TPT) and an energy pile system constructed on the site of the Incheon International Airport (IIA). First, an economic analysis of the GSHP system was conducted for the second passenger terminal of the IIA considering actual influencing factors such as government support and the residual value of the equipment. The analysis results showed that the economic efficiency of the GSHP system could be increased owing to several influential factors. Second, a multiple regression analysis was conducted using different independent variables in order to analyze the influence indices with regard to the LCC results. Every independent index, in this case the initial construction cost, lifespan of the equipment, discount rate and the amount of price inflation can affect the LCC results. Third, a GSHP system using an energy pile was installed on the site of the construction laboratory institute of the IIA. TPTs of W-shape and spiral-coil-type GHEs were conducted in continuous and intermittent operation modes, respectively, prior to system operation of the energy pile. A cooling GSHP system in the energy pile was operated in both the continuous and intermittent modes, and the LCC was calculated. Furthermore, the smart operation mode and LCC were analyzed considering the application of a thermal storage tank.

Effect of Temperature on Joint Movement of JPCP at Its Early Age (재령초기 콘크리트포장 줄눈거동에 미치는 온도의 영향)

  • Choi, Ki-Hyo;Jeong, Jin-Hoon;Chun, Sung-Han;Park, Moon-Gil
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.340-343
    • /
    • 2007
  • The temperature variation of concrete pavement at early-age significantly affects the initiation and movement of joint cracks. For this analysis, we have built on IIA(Incheon International Airport) concrete pavement construction zone, and we measured the temperature and movement of the concrete slabs by using thermocouples, moisture sensors, V/W strain gages, and Demac discs. The analysis results showed that pavement's temperature significantly affected the joint movement. The widths of the joint cracks increased at evening and early in the morning when the temperature dropped but, those decreased in the day time when the temperature rose because of the effect of thermal expansion of the concrete slabs. The movements of the joints where the cracks never developed showed opposite trend to the cracked joints.

  • PDF

The development device of Gwangyang port and Gwangyang bay in accordance with its free economic zone (광양항 및 광양만권 경제자유구역의 활성화 방안에 관한 연구)

  • 장흥훈
    • Journal of Korea Port Economic Association
    • /
    • v.20 no.1
    • /
    • pp.123-140
    • /
    • 2004
  • With the globalization of economy, there is keen competition among rountries to be a logistics hub and companies are striving to be first in establishing logistics system centering on advantageous sites, especially airport and seaports, to perform supply, production and distribution. Korea competing with Northeast Asia countries is also working out strategies in order to make Korea peninsula a logistics center of Northeast Asia taking advantage of its geographical strength. Gwangyang port has designated as Free Economic Zone together with Pusan and Jinhae, Incheon from October 24th, 2003. However, the introduction of Free Economic Zone in Korea lagged behind other major countries and it has a lot of operational problems. Approximately 600 areas worldwide are designated and operated as a Free Economic Zone and Gwangyang port and its surrounding area has several points to be settled as one of FEZ. First one is its limited functions and related laws. Next is imperfection on development, investment and management system of the hinterland. Lark of promotion activities could be one of the problems. This paper analyzes the above problems and presents various measures to activate Gwangyang Port and Gwangyang Free Economic Zone as follows Benchmarking to promote Gwangyang Free Economic Zone as follows Benchmarking other countries' system, governmental support, introduction & logistics functions, early development of the hinterland, supply of effective one-stop service, investment attraction into the area and diversified promotion & marketing activities.

  • PDF