• Title/Summary/Keyword: In-su

Search Result 42,738, Processing Time 0.095 seconds

Bronchial Brushing and Bronchial Washing for Diagnosis of Central Lung Cancer (중심형 폐암 진단을 위한 기관지찰과술과 기관지세척술)

  • Park, Ki-Su;Park, Jae-Yong;Cha, Seung-Ick;Son, Ji-Woong;Kim, Kwan-Young;Kim, Jeong-Seok;Chae, Sang-Cheol;Kang, Tae-Kyong;Park, Tae-In;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.817-825
    • /
    • 1999
  • Background : Forceps biopsy, bronchial brushing, and bronchial washing are used in conjunction with bronchoscopy to provide specimens for histologic and cytologic analysis in patients with suspected lung cancer. This study was performed to evaluate how many times brushing should be done and how much fluid should be used during bronchial washing for increasing diagnostic yield, and to evaluate which combination of these procedures gives the highest diagnostic yield. Methods : Forty patients, with suspected lung cancer, who had bronchoscopically visible lesions were enrolled in this prospective study. During one bronchoscopic examination four forceps biopsies, four bronchial brushings, and bronchial washing were done in all patients. The patients were divided into four groups by the amount of normal saline used for bronchial washing; group I, 10 ml ; group II, 20ml ; group III 30ml, and group IV, 40ml. We analyzed the results in 36 patients confirmed as lung cancer. Results : The diagnostic sensitivity of bronchial washing before and after forceps biopsy and bronchial brushing were 36% and 28%, respectively. The cumulative diagnostic sensitivity of bronchial washing was 47% and significantly higher than that of bronchial washing before or after forceps biopsy and bronchial brushing (p<0.05). The diagnostic sensitivity of bronchial washing with saline of 30ml was significantly higher than that of bronchial washing with saline of 10ml or 20ml (p<0.05). The diagnostic sensitivity of the first brushing was 75%, the second brushing 78%, the third brushing 83%, and the fourth brushing 67%. With repeated brushing up to three times, the diagnostic sensitivity increased to 92% (p<0.05). However, inclusion of the fourth brushing did not give a further increase of the diagnostic sensitivity. The diagnostic sensitivity of forceps biopsy was 86%. The diagnostic sensitivities of forceps biopsy by the type of bronchial lesion were as follows: tumor, 88%; infiltration, 67%; infiltration with nodularity, 80%; and collapse, 100%. The combination of forceps biopsy and bronchial washing gave a diagnostic sensitivity of 89%. The diagnostic sensitivity of combining forceps biopsy with bronchial brushing was 97%. Addition of bronchial washing did not increase the diagnostic yield over forceps biopsy and bronchial brushing. Conclusion : In patients with central lung cancer, forceps biopsies and repeated brushings up to three times should be done for maximal diagnostic yield.

  • PDF

Development of Analytical Method for Detection of Fungicide Validamycin A Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Validamycin A의 시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Park, Shin-min;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Validamycin A is an aminoglycoside fungicide produced by Streptomyces hygroscopicus that inhibits trehalase. The purpose of this study was to develop a method for detecting validamycin A in agricultural samples to establish MRL values for use in Korea. The validamycin A residues in samples were extracted using methanol/water (50/50, v/v) and purified with a hydrophilic-lipophilic balance (HLB) cartridges. The analyte was quantified and confirmed by liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~0.5 ng) into a blank extract with $R^2$ > 0.99. The limits of detection and quantification were 0.005 and 0.01 mg/kg, respectively. For validation validamycin A, recovery studies were carried out three different concentration levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n = 5) with five replicates at each level. The average recovery range was from 72.5~118.3%, with relative standard deviation (RSD) less than 10.3%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the NIFDS (National Institute of Food and Drug Safety) guideline (2016). Therefore, the proposed analytical method is accurate, effective and sensitive for validamycin A determination in agricultural commodities.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

Analysis of Korean Dietary Patterns using Food Intake Data - Focusing on Kimchi and Alcoholic Beverages (식품섭취량을 활용한 우리나라 식이 패턴 분석 - 김치류 및 주류 중심으로)

  • Kim, Soo-Hwaun;Choi, Jang-Duck;Kim, Sheen-Hee;Lee, Joon-Goo;Kwon, Yu-Jihn;Shin, Choonshik;Shin, Min-Su;Chun, So-Young;Kang, Gil-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.251-262
    • /
    • 2019
  • In this study, we analyzed Korean dietary habits with food intake data from the Korea National Health and Nutrition Examination Survey (KNHANES) and the Korea Centers for Disease Control and Prevention and we proposed a set of management guidelines for future Korean dietary habits. A total of 839 food items (1,419 foods) were analyzed according to the food catagories in "Food Code", which is the representative food classification system in Korea. The average total daily food intake was 1,585.77 g/day, with raw and processed foods accounting for 858.96 g/day and 726.81 g/day, respectively. Cereal grains contributed to the highest proportion of the food intake. Over 90% of subjects consumed cereal grains (99.09%) and root and tuber vegetables (95.80%) among the top 15 consumed food groups. According to the analysis by item, rice, Korean cabbage kimchi, apple, radish, egg, chili pepper, onion, wheat, soybean curds, potato, cucumber and pork were major (at least 1% of the average daily intake, 158.6 g/day) and frequently (eaten by more than 25% of subjects, 5,168 persons) consumed food items, and Korean spices were at the top of this list. In the case of kimchi, the proportion of intake of Korean cabbage kimchi (64.89 g/day) was the highest. In the case of alcoholic beverages, intake was highest by order of beer (63.53 g/day), soju (39.11 g/day) and makgeolli (19.70 g/day), and intake frequency was high in order of soju (11.3%), beer (7.2%), and sake (6.6%). Analysis results by seasonal intake trends showed that cereal grains have steadily decreased and beverages have slightly risen. In the case of alcoholic beverage consumption frequency, some kinds of makgeolli, wine, sake, and black raspberry wine have decreased gradually year by year. The consumption trend for kimchi has been gradually decreasing as well.

The Origin of Radioactive Elements Found in Groundwater Within the Chiaksan Gneiss Complex: Focusing on the Relationship with Minerals of the Surrounding Geology (치악산 편마암 복합체에 분포하는 지하수 내 함유된 방사성 원소의 기원: 주변 지질을 구성하는 광물과의 연관성을 중심으로)

  • Kim, Hyeong-Gyu;Lee, Sang-Woo;Kim, Soon-Oh;Jeong, Do-Hwan;Kim, Moon-Su;Kim, Hyun-Koo;Jeong, Jong Ok
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.2
    • /
    • pp.153-168
    • /
    • 2022
  • Petrological and mineralogical analyses were conducted to identify minerals containing radioactive elements (uranium) in the Chiaksan gneiss complex and to confirm their association with the surrounding groundwater. Fourteen minerals were identified through the microscopic and electron microscopy (SEMEDS) investigation. The principal minerals included plagioclase, biotite, quartz, alkali feldspar, chlorite, and calcite. Minor minerals were sphene, allanite, apatite, zircon, thorite, titanite, pyrite, and galena. A small amount of thorite was observed in the size of ~1 mm within macrocrystalline allanite. Allanite, which includes a large amount of rare earth elements, appeared in three distinctive patterns. The results of the EPMA analyses indicated that macrocrystalline allanite had higher elemental contents of TiO2~1.70 wt.%, Ce2O3~11.86 wt.%, FeO ~13.31 wt.%, MgO ~0.90 wt.% and ThO2 ~1.06 wt.% with the lowest average content of Al2O3 17.35 ± 2.15 wt.% (n = 7), CaO 12.13 ± 1.81 wt.% (n = 7). An allanite existing at the edge of the sphenes encompassing titanites had a higher element content of Al2O3 ~24.00 wt.%, Nd2O3 ~5.10 wt.%, Sm2O3~0.66 wt.%, Dy2O3~0.86 wt.% and Y2O3~1.38 wt.% with the lowest average content of TiO2 0.35 ± 0.21 wt.% (n = 11), Ce2O3 5.25 ± 1.03 wt.% (n = 11), FeO 9.84 ± 0.26 wt.% (n = 11), MgO 0.12 ± 0.05 wt.% (n = 11), and La2O3 1.49 ± 0.29 wt.% (n = 11). Allanites in a matrix of parental rocks exhibited intermediate values between the two elemental compositions mentioned above. None of the uranium-rich minerals were observed in the migmatitic gneiss within the study area. Consequently, the origin of uranium in the groundwater was not associated with the geology of the surrounding environment, but our investigation proved the existence of abundant allanites containing significant amounts of radioactive thorium and rare earth elements.

Development of Tuna Purse Seine Fishery in Korea and the Countries Concerned (한국(韓國) 및 관련각국((關聯各國)의 다랑어 선망어업(旋網漁業) 발달과정(發達過程))

  • Hyun, Jong-Su;Lee, Byoung-Gee;Kim, Hyoung-Seok;Yae, Young-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.4 no.1
    • /
    • pp.30-46
    • /
    • 1992
  • Korea's first exploratory tuna fishing was done with a used longliner in 1957. Then the commercial fishing has been made steady headway since the 1960's and grown up to one of major tuna fishing countries in 1970's. The tuna fishing aimed primarily at acquiring foreign currency, then tuna was exported directly from the overseas fishing base. Tuna, however, has been gradually favored by Koreans as high-proteined foods according to the growth of GNP since the 1970's. In 1980, the canned tuna began to be produced and sold at home. And so the demand of raw tuna for cannaries has steeply increased not only for home but also for abroad, and stimulated the development of tuna purse seine fishery. The author carried out a study on the development of tuna purse seine fishery in Korea and countries concerned-the United States and Japan-because it is recognized to be significant for the further development of this fishery. Just as purse seining was originated in the United States, so tuna purse seining was also pioneered by Californian fishermen in the west coastal waters of the United States (Eastern Pacific Ocean). They started to produce the canned tuna in the early 1900's, and the demand for raw tuna began to be increased rapidly. In those days, tuna was mostly caught by pole-and-line, but the catch amount was far away from the demand. To satisfy this demand, they began to try out fishing tuna by the use of purse seine which had been born in the eastern waters in the 1820's and applied to catch white fishes in the western waters of the United States in those days. Even though their trial was technically successful through severe trial and error, a new problem was raised on the management of tuna resource and the preservation of porpoise which was occassionally caught with tuna. Then the Inter-American Tropical Tuna Commission (IATTC) was established by countries neighboring to the United States in 1950 and they set up the Commission's Yellowfin Regulatory Area (CYRA) and regulated the annual quota for yellowfin. Then, American owners tried to send their seiners to the Western African waters to expand the fishing ground in 1967 and to the Centeral-Western Pacfic in 1974, and the fishing ground was widely expanded. The number of the United States' purse seiners amounted to about 150 in 1980, but the enthusiasm was gradually cooled thereafter and the number of seiner was decreased to 67 in 1986. The landing of tuna by purse seiners in the United States after 1980 maintains 200 thousands M/T or so with a little increase despite the decreasing of domestic seiners. This shows that the landing by foreign seiners are increasing, compared with the landing by domestic seiners are decreasing. In Japan, even though purse seining was introduced in 1880, they had fished tuna by longline and pole-and -line until the tuna purse seining was introduced from the United States again. In the 1960's, Japanese tuna seiners made the exploratory fishing in the South-western Pacific and West African waters with a limited success. In 1971, the government-funded research center "JARMRAC" conducted the exploratory fishing which extended to the Central American waters, the Asia-Pacific Region and the South-western Pacific. It had also much difficulties, till they improved the fishing gear adaptable to the new fishing condition in the South-western Pacific. Japanese government has begun to licence 32 single seiners and 7 group seiners since 1980 and their standard has lasted up to now. The catch in the Pacific Islands Region amounted to 160 thousands M/T in 1986. Korea's tuna purse seine fishery was originated in 1971 by Jedong Industrial Co., Ltd. with three used tuna purse seiners purchased from the United States, and they began to fish in the Eastern Pacific, but failed owing to the superannuation of vessel and the infancy of fishing technique. The second challenge was done by Dongwon Industrial Co., Ltd. in 1979, with one used seiner purchased from the United States, and started to fish in the Eastern Pacific. Even though the first trial was almost unsuccessful but they could obtain the noticeable success by removing the vessel to the South-western Pacific in 1980. This success stimulated the Korean entherprisers to take part in this fishery, and the number of Korean tuna purse seiners has been increased rapidly in accordance with the increased demand for raw tuna. The number of vessels actually at work amounted to 36 in 1990 and they operate in the South-western Pacific. The annual catch of tuna by purse seiners amounted to 170 thousands M/T in 1990 and ranked to one of the major tuna purse seining countries in the world.

  • PDF

Accelerometer-based Gesture Recognition for Robot Interface (로봇 인터페이스 활용을 위한 가속도 센서 기반 제스처 인식)

  • Jang, Min-Su;Cho, Yong-Suk;Kim, Jae-Hong;Sohn, Joo-Chan
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.1
    • /
    • pp.53-69
    • /
    • 2011
  • Vision and voice-based technologies are commonly utilized for human-robot interaction. But it is widely recognized that the performance of vision and voice-based interaction systems is deteriorated by a large margin in the real-world situations due to environmental and user variances. Human users need to be very cooperative to get reasonable performance, which significantly limits the usability of the vision and voice-based human-robot interaction technologies. As a result, touch screens are still the major medium of human-robot interaction for the real-world applications. To empower the usability of robots for various services, alternative interaction technologies should be developed to complement the problems of vision and voice-based technologies. In this paper, we propose the use of accelerometer-based gesture interface as one of the alternative technologies, because accelerometers are effective in detecting the movements of human body, while their performance is not limited by environmental contexts such as lighting conditions or camera's field-of-view. Moreover, accelerometers are widely available nowadays in many mobile devices. We tackle the problem of classifying acceleration signal patterns of 26 English alphabets, which is one of the essential repertoires for the realization of education services based on robots. Recognizing 26 English handwriting patterns based on accelerometers is a very difficult task to take over because of its large scale of pattern classes and the complexity of each pattern. The most difficult problem that has been undertaken which is similar to our problem was recognizing acceleration signal patterns of 10 handwritten digits. Most previous studies dealt with pattern sets of 8~10 simple and easily distinguishable gestures that are useful for controlling home appliances, computer applications, robots etc. Good features are essential for the success of pattern recognition. To promote the discriminative power upon complex English alphabet patterns, we extracted 'motion trajectories' out of input acceleration signal and used them as the main feature. Investigative experiments showed that classifiers based on trajectory performed 3%~5% better than those with raw features e.g. acceleration signal itself or statistical figures. To minimize the distortion of trajectories, we applied a simple but effective set of smoothing filters and band-pass filters. It is well known that acceleration patterns for the same gesture is very different among different performers. To tackle the problem, online incremental learning is applied for our system to make it adaptive to the users' distinctive motion properties. Our system is based on instance-based learning (IBL) where each training sample is memorized as a reference pattern. Brute-force incremental learning in IBL continuously accumulates reference patterns, which is a problem because it not only slows down the classification but also downgrades the recall performance. Regarding the latter phenomenon, we observed a tendency that as the number of reference patterns grows, some reference patterns contribute more to the false positive classification. Thus, we devised an algorithm for optimizing the reference pattern set based on the positive and negative contribution of each reference pattern. The algorithm is performed periodically to remove reference patterns that have a very low positive contribution or a high negative contribution. Experiments were performed on 6500 gesture patterns collected from 50 adults of 30~50 years old. Each alphabet was performed 5 times per participant using $Nintendo{(R)}$ $Wii^{TM}$ remote. Acceleration signal was sampled in 100hz on 3 axes. Mean recall rate for all the alphabets was 95.48%. Some alphabets recorded very low recall rate and exhibited very high pairwise confusion rate. Major confusion pairs are D(88%) and P(74%), I(81%) and U(75%), N(88%) and W(100%). Though W was recalled perfectly, it contributed much to the false positive classification of N. By comparison with major previous results from VTT (96% for 8 control gestures), CMU (97% for 10 control gestures) and Samsung Electronics(97% for 10 digits and a control gesture), we could find that the performance of our system is superior regarding the number of pattern classes and the complexity of patterns. Using our gesture interaction system, we conducted 2 case studies of robot-based edutainment services. The services were implemented on various robot platforms and mobile devices including $iPhone^{TM}$. The participating children exhibited improved concentration and active reaction on the service with our gesture interface. To prove the effectiveness of our gesture interface, a test was taken by the children after experiencing an English teaching service. The test result showed that those who played with the gesture interface-based robot content marked 10% better score than those with conventional teaching. We conclude that the accelerometer-based gesture interface is a promising technology for flourishing real-world robot-based services and content by complementing the limits of today's conventional interfaces e.g. touch screen, vision and voice.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Comparison of Diagnostic Value between the Absolute and Relative Uptake Rate on $^{99m}Tc-DMSA$ Renal Scan of Children with Febrile Urinary Tract Infection (발열성 요로감염 환아의 $^{99m}Tc-DMSA$ 신주사에서 절대적 신섭취율과 상대적 신섭취율의 진단적 가치에 대한 비교연구)

  • Kim Hee-Yeon;Bae Sang-Young;Whang Su-Ja;Park Eun-Ae;Kim Ho-Sung;Seo Jung-Wan;Lee Sung-Joo
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.24-30
    • /
    • 1997
  • Purpose: To evaluate the diagnositc value of the absolute and relative renal uptake rates on $^{99m}Tc-DMSA$ renal scan of children with febrile UTI. Method: The absolute and relative renal uptake rates of $^{99m}Tc-DMSA$ were checked in 68 children with febrile urinary tract infection (35 with unilateral focal defect; 13 with bilateral focal defect; and 20 with diffuse bilateral defect) and 49 children with afebrile UTI and normal $^{99m}Tc-DMSA$ renal scan as control. Results: The renal absolute uptake rate in the control group were $21.8{\pm}3.9%(right),\;22.2{\pm}3.9%(left),\;and\;44.2{\pm}7.8%(total)$. The absolute uptake rate gradually increased until the age 12 months and then was stationary. In febrile UTI with unilateral focal defect on the $^{99m}Tc-DMSA$ renal scan, both relative and absolute uptake rates were similarly diagnostic ($41.2{\pm}9.7%,\;16.5{\pm}5.4%$ vs $50.0{\pm}2.6%,\;22.0{\pm}3.9%$, p<0.01). In acute pyelonephritis with bilateral focal defect on the $^{99m}Tc-DMSA$ renal scan, the absolute uptake rate was significantly more diagnostic than the relative uptake rate[$17.3{\pm}5.3%$ (right), $17.4{\pm}5.3%\;(left),\;vs\;21.8{\pm}3.9%,\;(right)\;22.2{\pm}3.9%$, (left)% p<0.01]. In febrile UTI with bilateral diffuse defects on the $^{99m}Tc-DMSA$ renal scan, the absolute uptake rate was significantly diagnostic than the relative uptake rate [$18.1{\pm}3.9%\;(right),\;18.4{\pm}3.8%\;(left),\;vs\;21.8{\pm}3.9%,\;(right)\;22.2{\pm}3.9%$(left), p<0.01]. Conclusion: In the $^{99m}Tc-DMSA$ renal scan, the absolute uptake rate was more useful than the relative uptake rate to evaluate bilateral acute pyelonephritis.

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF