• Title/Summary/Keyword: In-plane alignment

Search Result 174, Processing Time 0.023 seconds

A Comparison of Knee and Ankle Coronal Plane Alignment According to Quadriceps Exercise Method in Early Phase of Total Knee Arthroplasty: Lower Extremity Isometric Co-Contraction and Quadriceps Isolated Isometric Contraction (슬관절 전치환술 초기의 대퇴사두근 운동 방법에 따른 슬관절과 족관절의 관상면 정렬 비교: 하지 등척성 동시수축과 대퇴사두근 단독 등척성 수축)

  • Kim, Hyung-soo;Jeong, Young-hee
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Background: Total knee arthroplasty (TKA) recovers the alignment of the knee joint, but fails to automatically restore the alignment and function of the hip and ankle joints. It may affect the alignment and stability of the knee joint, therefore therapeutic intervention in hip and ankle joint is necessary for the rehabilitation process after TKA. Objects: The aim of this study was to comparison of the effects of the two exercise methods on the coronal plane alignment after TKA. This study conducted an experiment by dividing subjects into a lower extremity isometric co-contraction group (LEIC) and a quadriceps isolated isometric contraction (QIIC) group. Methods: A total of 37 subjects were randomly assigned to the LEIC ($n_1$=19) or the QIIC ($n_2$=18). Exercise was applied to five times per week for three weeks, starting on the eighth day after surgery. Range of motion exercises were performed as a common intervention and then each group performed quadriceps isometric contraction exercises with 10 sets of 5 repetitions. Radiological imaging was performed prior to surgery, one month and six months after surgery. In addition, the hip-knee-ankle angle (HKA) and tibiotalar angle (TTA) were measured. Results: The HKA was close to neutral in the LEIC rather than the QIIC (p<.05). The LEIC showed varus and the QIIC exhibited valgus TTA (p<.05). In a comparison of HKA and TTA over time, there was no significant change in either group (p>.05). According to the comparison of the TTA before surgery, the LEIC showed significant changes in the varus direction (p<.05), while there was no significant change in the QIIC (p>.05). Conclusion: The LEIC method triggered changes in the TTA and brought the HKA close to the neutral. Thus, LEIC is more effective than QIIC in creating stability in the coronal plane alignment of the knee and ankle joints after TKA.

3-Dimensional Gait analysis and the relationship between lower limb alignment and knee adduction moment in elderly healthy women (3차원적 동작 분석기를 이용한 건강한 여자 노인의 하지 정렬 상태와 슬관절 내전 모멘트의 상관 관계에 관한 연구)

  • Cho, You-Mi;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.90-101
    • /
    • 2003
  • Gait analysis can provide a better understanding of how the alignment of the lower limb and foot can contribute to force observed at the knee. Anatomic and mechanical factors that affect loading in the knee pint can contribute to pathologic change seen at the knee in degenerative pint disease and should be considered in treatment plan. The purpose of this study is to present the gait analysis data and to determine whether there is any relationships between alignment of the lower limb, foot progression angle and knee pint moments in elderly healthy women with 3-dimensional motion analyzer. The results were as follows; 1. Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04 m, Step length was 0.56 m. 2. According to the parameters of kinematics, the maximal knee flexion angle through swing phase showed left $46.82^{\circ}$, right $40.19^{\circ}$ and the maximal knee extension angle showed left $-1.32^{\circ}$, right $2.01^{\circ}$. knee varus showed left $26.90^{\circ}$, right $30.93^{\circ}$. 3. Moment, one of kinetic parameters of knee pint the maximal flexion moment showed left 0.363. Nm/kg, right 0.464 Nm/kg and maximal extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximal. adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg and the maximal internal rotatory moment showed left 0.13 Nm/kg, right 0.140 Nm/kg. 4. On sagittal plane, the maximal power of knee joint showed left 0.571 J/kg, right 0.629 J/kg. On coronal plane, the maximal power of knee joint showed left 0.11 J/kg, right 0.12 J/kg. On transverse plane, the maximal power of knee joint showed left 0.058 J/kg, right 0.072 J/kg. 5. The subject who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase. 6. The subject who had large foot progression angle had statistically lower in knee adduction moment in late stance phase. A relationship was observed between the alignment of the lower extremity and the adduction moment of the knee joint during stance phase. Hence, we need some research to figure, out the change of adduction moment according to the sort of knee joint osteoarthritis and the normal geriatrics as well. And we also require more effective, specific therapeutic program by making use of those background of researches.

  • PDF

DC Influence Between Pixel Electrode and Alignment Layer in In-plane Switching Mode LCD

  • Lim, Young-Nam;Lee, Tae-Rim;Park, Byoung-Gyu;Roh, Seung-Kwang;Kim, Hyun-Chul;Kim, Hyun-Seung;Kim, Kyeong-Jin;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.677-680
    • /
    • 2009
  • DC influence between pixel electrode and alignment layer (AL) in in-plane switching mode LCD was analyzed through DC equivalence-circuit equation induction, DC charge-discharge simulation, luminance and residual-DC measurement systems using test patterned (TP) cell. DC discharging rate (DDR) of single layer electrode was faster than that of double layer electrode and DDR of low resistance AL was faster than that of high resistance AL. DC discharging characteristics had a close relation to layer number and resistance between two electrodes.

  • PDF

A Study on the Development of the Rotary Stage for Multi-Channel Optical Alignment System (다채널 광정렬 장치 로터리 스테이지 개발에 관한 연구)

  • 정상화;차경래
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.143-148
    • /
    • 2003
  • In recent years, as the optical Communication systems are developed, the demands of essential parts such as splitter, coupler, WDM, and AWG filter are grow rapidly. The fabrication process for them is not, however, automatic. On that reason, the automation is needed for the grow of productivity. The optical alignment and attach ment is the core process in fabrication. In this paper, the 6-axis rotary stage for multi-channel optical alignment system is developed and the dynamic characteristic of this system is studied.

  • PDF

The formation of Si V-groove for optical fiber alignment in optoelectronic devices (광전소자 패키징에서 광섬유 정렬을 위한 Si V-groove 형성)

  • 유영석;김영호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.3
    • /
    • pp.65-71
    • /
    • 1999
  • The effects of mask materials and etching solutions on the dimensional accuracy of V-groove were studied for the alignment between optoelectronic devices and optical fibers in optical packaging. PECVD nitride, LPCVD nitride, or thermal oxide($SiO_2$) was used as a mask material. The anisotropic etching solution was KOH(40wt%) or the mixture of KOH and IPA. LPCVB nitride has the best etching selectivity and thermal oxide was etched most rapidly in KOH(40wt%) at $85^{\circ}C$ among the mask materials studied here. The V-groove size enlarged than the designed value. This phenomenon was due to the undercutting benearth the mask layer from the etching toward Si (111) plane. The etch rate of (111) plane wart 0.034 - 0.037 $\mu\textrm{m}$/min in KOH(40wt%). This rate was almost same regardless of mask materials. When IPA added to KOH(40wt%), the etch rate of (100) plane and (111) plane decreased, but etching ratio of (100) to (111) plane increased. Consequently, the undercutting phenomenon due to etching toward (111) plane decreased and the size of V-groove could be controlled more accurately.

  • PDF

A Study on the Mechanism of Rotational Stage with Multi Degree of Freedom for Multi-Channel Optical Alignment System (다채널 광정렬 장치에서의 다자유도 회전 스테이지 동작 특성에 관한 연구)

  • 정상화;차경래;최석봉;김광호;박준호;이경형
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.219-224
    • /
    • 2004
  • In recent years, as the demands of VBNS(Very high speed Backbone Network Service) and VDSL(Very high-data rate Digital Subscriber Line) increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, WDM elements increase. The alignment and the attachment technology are very important to fabricate the optical elements for communication. In this paper, the mechanism of rotational stage, the contact sensing unit, and integrated control circuit for the optical alignment system are studied.

  • PDF

Tilted Homeotropic Alignment using Ion Beam Process; Development of Novel Inorganic thin films

  • Hwang, Byoung-Har;Kim, Kyung-Chan;Ahn, Han-Jin;Kim, Jong-Bok;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.450-452
    • /
    • 2005
  • The ion beam alignment technique is one of the potential and fascinating methods. However, there are merely a few reports about aligning nematic liquid crystals (NLCs) horizontally for in-plane switching mode (IPS) by means of low energy ion beam exposure on inorganic materials such as DLC. In this study, we have investigated the tilted vertical alignment of NLC by the ion beam technique on the thin films of various amorphous silicon compounds as new inorganic alignment materials. Appropriate pretilt angles of NLC with preferred orientation on these thin films were achieved. And the electro-optic property of vertically aligned single domain cells has been investigated.

  • PDF

Crystallization and In-plane Alignment Behavior of Pb(Zr, Ti)$O_3$ Films

  • Hwang, Kyu-Seog;Kim, Byung-Hoon
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.191-194
    • /
    • 1997
  • Epitaxial Pb(Zr, Ti)O3(PZT) thin films were prepared on MgO(100) substrates by dipping-pyrolysis (DP) process using metal naphthenates as starting materials, and effects of pyrolysis and final heat-treatment conditions on the film's orientation were investigated. Solid-state epitaxial growth of PZT proceeds at lower temperature around 650℃ from the precursor pyrolyzed at 350 and 500℃. The in-plane alignment of the PZT films depends not only on the final heat-treatment temperature but on the pyrolysis conditions; the films, pyrolyzed at a higher temperature for a short time, i.e., at 500℃ for 10 min, exhibited stronger orientation after the same final heat treatment at 650°∼750℃. The PZT films with the strongest orientation were prepared by pyrolysis under the above conditions followed by final heat treatment at 750℃.

  • PDF

Fabrication of the in-plane Aligned a-Axis Oriented $YBa_2Cu_3O_{7-x}$ Thin Films (평면배향된 a-축 수직 $YBa_2Cu_3O_{7-x}$ 고온초전도 박막의 제작)

  • 성건용;서정대
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.3
    • /
    • pp.313-320
    • /
    • 1996
  • We have fabricated an in-plane aligned a-axis oriented YBa2Cu3O7-x (a-YBCO) thin film on a LaSrGaO4(100) substrate with a PrBa2Cu3O7-x(PBCO) template layer by two step plused laser deposition using 308 nm XeCl excimer laser. A YBCO layer and PBCO layer grown at low temperatures were used as template layers. We have investigated the effect of the deposition temperature of template layers on the superconducting and struc-tural properties of in-plane aligned a-YBCO thin films. An optimal deposition temperature of the PBCO template layers was 630. In-plane aligned a-YBCO thin films showed an anisotropy ratio in resistivity of 11.5 and a zero resistance temperature of 88 K.

  • PDF

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF