• 제목/요약/키워드: In-Situ Soil

검색결과 758건 처리시간 0.024초

군말뚝효과를 고려한 수동말뚝의 해석기법 (Analysis Method of Passive Piles considering group effect)

  • 정상섬;원진오;김병철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.151-158
    • /
    • 2000
  • The lateral deformation of one row pile groups was investigated based on analytical study and a numerical analysis. The emphasis was on quantifing the load transfer of pile groups subjected to lateral soil movement. An analytical method to consider pile-soil interaction in weathered soil was developed using load-transfer curve methods. Through the comparative study, it is found that the prediction by present approach is in good agreement with the general trend observed by in-situ measurements.

  • PDF

1차원 수치모델과 현지측정에 의한 지중열전도율 및 보어홀 전열저항 해석에 관한 연구 (A Study on the Estimation of Soil Formation Thermal Conductivities and Borehole Resistances with One-Dimensional Numerical Model and In-Situ Field Tests)

  • 이세균;우정선;노정근;김대기
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.783-790
    • /
    • 2006
  • A one-dimensional numerical model coupled with parameter estimation is used to predict the effective thermal conductivities of soil formations and borehole resistances from in situ field test data. In this application a new method of using initial ignoring time (IIT) obtained from error estimation is tried and turned out to be successful in determining soil thermal conductivities. This method is used for single-U and double-U borehole system. The results of this method are compared and agreed well with those of existing software (GPM) in the analysis of single-U borehole data. In the analysis of double-U borehole data this method seems to be better in predicting soil and borehole properties.

과산화수소를 이용한 현장원위치 화학적 산화법과 공기분사법(Air-sparging)을 연계한 디젤 오염 토양/지하수 동시 정화 실내 실험 연구 (Study on the Combination of In-situ Chemical Oxidation Method by using Hydrogen Peroxide with the Air-sparging Method for Diesel Contaminated Soil and Groundwater)

  • 김남호;김인수;최애정;이민희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권6호
    • /
    • pp.8-17
    • /
    • 2006
  • 현장비원위치(Ex-situ) 공법 적용이 불가능한 부지에서, 디젤로 오염된 오염 토양과 지하수를 동시에 복원하기 위하여 과산화수소를 이용한 현장원위치 화학적 산화법(chemical oxidation)과 공기분사법(air-sparging)을 연계한 복합 복원 공정의 정화 효율 규명을 위한 실내 실험을 실시하였다. TPH 농도가 2,401 mg/kg(A 토양)과 9,551 mg/kg(B 토양)인 두 종류의 현장 오염 토양을 대상으로 과산화수소용액을 이용한 화학적 산화법의 디젤 제거 효율 규명을 위한 배치(회분식) 실험 결과, 과산화수소 50% 용액에 의해 토양 초기 TPH 농도의 18%와 15%까지 감소하였다. 과산화수소 용액 20%를 이용한 칼럼 세정 실험 결과, 세정에 의해서 A 토양과 B 토양의 경우 각각 초기 TPH 양의 78%와 72%가 제거되었다. 칼럼 실험에서 과산화수소의 산화반응에 의해 완전 분해되어 무기가스상(주로 $CO_2$$H_2O$)으로 제거된 양까지 고려한다면, 과산화수소용액이 오염 토양과 접촉하면서 충분한 산화과정을 거쳐 대부분의 유류가 토양으로부터 제거되었음을 알 수 있었다. 공기분사법을 이용한 디젤 오염 지하수 정화 실험의 경우, TPH 농도가 820 mg/L인 고농도의 인공 지하수 경우에도 공기분사 72시간 이내에 폐수배출허용기준인 5 mg/L 보다 낮아져, 디젤 제거 효율이 매우 높은 것으로 나타났다. 다만, 오염 토양 내 다량의 디젤 자유상이 존재하는 경우 토양으로부터 지하수로의 지속적인 자유상 디젤의 질량 이동에 의하여, 공기분사법의 지하수 정화 효율은 매우 낮았다. 마지막으로, 과산화수소를 이용한 현장원위치 화학적 산화법과 공기분사법을 연계한 복합 공정의 디젤 정화 효율을 규명하는 박스 실험을 실시하였다. 토양 내 자유상 디젤을 먼저 제거하기 위해 과산화수소 용액을 이용한 토양세정법을 실시한 후, 토양 내 TPH가 제거 되는 정도에 따라 후차적으로 공기분사법을 적용함으로써 토양 및 지하수로부터 디젤을 효과적으로 제거할 수 있었다. 20% 과산화수소 용액의 23 L 세정과 2,160 L의 공기분사에 의해 토양의 TPH 농도는 9,551 mg/kg에서 390 mg/kg으로 낮아졌으며, 오염 지하수의 TPH 농도도 5 mg/L 이하로 낮출 수 있었다. 본 실험들에서 얻어진 결과를 바탕으로 실제 현장에서 대단위 공정을 운영하는데 필요한 복원 공정의 최적 조건들을 도출해 낼 수 있으리라 판단되며, 유류로 오염된 토양 뿐 아니라 오염 지하수까지 동시에 정화할 수 있는 복합 공정 개발을 위한 중요한 기술 자료로 이용될 수 있을 것으로 판단된다.

Monitoring of Bacterial Community in a Coniferous Forest Soil After a Wildfire

  • Kim Ok-Sun;Yoo Jae-Jun;Lee Dong-Hun;Ahn Tae-Seok;Song Hong-Gyu
    • Journal of Microbiology
    • /
    • 제42권4호
    • /
    • pp.278-284
    • /
    • 2004
  • Changes in the soil bacterial community of a coniferous forest were analyzed to assess microbial responses to wildfire. Soil samples were collected from three different depths in lightly and severely burned areas, as well as a nearby unburned control area. Direct bacterial counts ranged from $3.3­22.6\times10^8\;cells/(g{\cdot}soil).$ In surface soil, direct bacterial counts of unburned soil exhibited a great degree of fluctuation. Those in lightly burned soil changed less, but no significant variation was observed in the severely burned soil. The fluctuations of direct bacterial count were less in the middle and deep soil lay­ers. The structure of the bacterial community was analyzed via the fluorescent in situ hybridization method. The number of bacteria detected with the eubacteria-targeted probe out of the direct bacterial count varied from $30.3\;to\;84.7\%,$ and these ratios were generally higher in the burned soils than in the unburned control soils. In the surface unburned soil, the ratios of $\alpha,\;\beta\;and\;gamma-proteobacteria,$ Cytoph­aga-Flavobacterium group, and other eubacteria groups to total eubacteria were 9.9, 10.6, 15.5, 9.0, and $55.0\%,$ respectively, and these ratios were relatively stable. The ratios of $\alpha,\;\beta\;and\;gamma-proteobacteria,$ and Cytophaga-Flavobacterium group to total eubacteria increased immediately after the wildfire, and the other eubacterial proportions decreased in the surface and middle layer soils. By way of contrast, the composition of the 5 groups of eubacteria in the subsurface soil exhibited no significant fluctuations dur­ing the entire period. The total bacterial population and bacterial community structure disturbed by wildfire soon began to recover, and original levels seemed to be restored 3 months after the wildfire.

철도사면파괴 원인 및 대책공법 적용을 위한 강도정수 결정 (Cause of Rall Road Slope Failure and Determination of Soil Strength for Remedy)

  • 이승현;김병일
    • 한국방재학회 논문집
    • /
    • 제4권3호
    • /
    • pp.25-31
    • /
    • 2004
  • 철도사면은 예상치 못한 연약지반의 존재로 인해 붕괴될 수 있다. 이 연구는 철도사면의 파괴원인을 규명하고 대책공법 적용을 위한 강도정수를 결정하는데 그 목적이 있다. 사면파괴의 원인을 파악하기 위하여 시추조사, 콘관입시험, 현장베인시험 등이 수행되었다. 또한 연약지반의 강도정수를 구하기 위해 불교란상태로 시료를 채취하여 실내시험을 수행하였다. 현장원위치시험 및 실내시험 결과 사면 파괴의 원인은 과압밀점토의 점진적 파괴에 따른 연약지반 강도저하영역의 전파에 기인한 것으로 밝혀졌다.

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • 제4권1호
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

Improved prediction of soil liquefaction susceptibility using ensemble learning algorithms

  • Satyam Tiwari;Sarat K. Das;Madhumita Mohanty;Prakhar
    • Geomechanics and Engineering
    • /
    • 제37권5호
    • /
    • pp.475-498
    • /
    • 2024
  • The prediction of the susceptibility of soil to liquefaction using a limited set of parameters, particularly when dealing with highly unbalanced databases is a challenging problem. The current study focuses on different ensemble learning classification algorithms using highly unbalanced databases of results from in-situ tests; standard penetration test (SPT), shear wave velocity (Vs) test, and cone penetration test (CPT). The input parameters for these datasets consist of earthquake intensity parameters, strong ground motion parameters, and in-situ soil testing parameters. liquefaction index serving as the binary output parameter. After a rigorous comparison with existing literature, extreme gradient boosting (XGBoost), bagging, and random forest (RF) emerge as the most efficient models for liquefaction instance classification across different datasets. Notably, for SPT and Vs-based models, XGBoost exhibits superior performance, followed by Light gradient boosting machine (LightGBM) and Bagging, while for CPT-based models, Bagging ranks highest, followed by Gradient boosting and random forest, with CPT-based models demonstrating lower Gmean(error), rendering them preferable for soil liquefaction susceptibility prediction. Key parameters influencing model performance include internal friction angle of soil (ϕ) and percentage of fines less than 75 µ (F75) for SPT and Vs data and normalized average cone tip resistance (qc) and peak horizontal ground acceleration (amax) for CPT data. It was also observed that the addition of Vs measurement to SPT data increased the efficiency of the prediction in comparison to only SPT data. Furthermore, to enhance usability, a graphical user interface (GUI) for seamless classification operations based on provided input parameters was proposed.

Elicitation of Innate Immunity by a Bacterial Volatile 2-Nonanone at Levels below Detection Limit in Tomato Rhizosphere

  • Riu, Myoungjoo;Kim, Man Su;Choi, Soo-Keun;Oh, Sang-Keun;Ryu, Choong-Min
    • Molecules and Cells
    • /
    • 제45권7호
    • /
    • pp.502-511
    • /
    • 2022
  • Bacterial volatile compounds (BVCs) exert beneficial effects on plant protection both directly and indirectly. Although BVCs have been detected in vitro, their detection in situ remains challenging. The purpose of this study was to investigate the possibility of BVCs detection under in situ condition and estimate the potentials of in situ BVC to plants at below detection limit. We developed a method for detecting BVCs released by the soil bacteria Bacillus velezensis strain GB03 and Streptomyces griseus strain S4-7 in situ using solid-phase microextraction coupled with gas chromatography-mass spectrometry (SPME-GC-MS). Additionally, we evaluated the BVC detection limit in the rhizosphere and induction of systemic immune response in tomato plants grown in the greenhouse. Two signature BVCs, 2-nonanone and caryolan-1-ol, of GB03 and S4-7 respectively were successfully detected using the soil-vial system. However, these BVCs could not be detected in the rhizosphere pretreated with strains GB03 and S4-7. The detection limit of 2-nonanone in the tomato rhizosphere was 1 µM. Unexpectedly, drench application of 2-nonanone at 10 nM concentration, which is below its detection limit, protected tomato seedlings against Pseudomonas syringae pv. tomato. Our finding highlights that BVCs, including 2-nonanone, released by a soil bacterium are functional even when present at a concentration below the detection limit of SPME-GC-MS.

항공유 오염 지역에서 주입정과 회수트렌치를 이용한 원위치 토양세정법 현장 적용 (A Field Study of Surfactant Enhanced In-Situ Remediation using Injection Wells and Recovery Trench at a Jet Oil Contaminated Site)

  • 이규상;김양빈;장재선;엄재연;송성호;김을영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권1호
    • /
    • pp.13-21
    • /
    • 2012
  • This study reports a surfactant-enhanced in-situ remediation treatment at a test site which is located in a hilly terrain. The leakage oils from a storage tank situated on the top of the hill contaminated soils and groundwater in the lower elevation. Sixteen vertical injection wells (11 m deep) were installed at the top of the hill to introduce 0.1-0.5 vol.% of non-ionic Tween-80 surfactant. The contaminated area that required remediation treatment was about $1,650\;m^2$. Two cycles of injecting surfactant solution followed by water were repeated over approximately 7.5 months: first cycle with 0.5 month of surfactant injection followed by 3 months of water injection, and second cycle with 1 month of surfactant followed by 3 months of water injection. The seasonal fluctuation in groundwater table was also considered in the selection of periods for surfactant and water injection. The results showed that the initial Total Petroleum Hydrocarbon (TPH) concentration of 1,041 mg/kg (maximum 3,605 mg/kg) was reduced significantly down to 76.6 mg/kg in average. After 2nd surfactant injection process finished, average TPH concentration of soils was reduced to 7.5% compared to initial concentration. Also, average BTEX concentration of soils was reduced to 10.8%. This resultes show that the surfactant enhanced in-situ remediation processes can be applicable to LNAPL contaminated site in field scale.

유류오염토양 복원을 위한 설계인자 선정에 관한 연구

  • 조장환;전권호;서창일;박정구
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.293-296
    • /
    • 2004
  • The objective of this study was to decide the designing factor for remediaton of the contaminated site. The soil and ground-water samples were analyzed and hydro- geological characteristics was assayed for the survey of pollution level. Also air-permeability test and MPN(most probable number) test were conducted for selecting the designing factor. The contaminants were mainly found in north-west part of the site and were expected to move toward the south. Ex-situ technology was expected more useful than in-situ one with the results of air-permeability test saying that air permeability was relatively low. Additional microbes were expected for remediation efficiency because residual microbes were loosely populated. The choosing of the designing factor was requisite for remediation of contaminated site.

  • PDF