• Title/Summary/Keyword: In-Phase Mode

Search Result 2,016, Processing Time 0.033 seconds

MODAL TESTING AND MODEL UPDATING OF A REAL SCALE NUCLEAR FUEL ROD

  • Park, Nam-Gyu;Rhee, Hui-Nam;Moon, Hoy-Ik;Jang, Young-Ki;Jeon, Sang-Youn;Kim, Jae-Ik
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.821-830
    • /
    • 2009
  • In this paper, modal testing and finite element modeling results to identify the modal parameters of a nuclear fuel rod as well as its cladding tube are discussed. A vertically standing full-size cladding tube and a fuel rod with lead pellets were used in the modal testing. As excessive flow-induced vibration causes a failure in fuel rods, such as fretting wear, the vibration level of fuel rods should be low enough to prevent failure of these components. Because vibration amplitude can be estimated based on the modal parameters, the dynamic characteristics must be determined during the design process. Therefore, finite element models are developed based on the test results. The effect of a lumped mass attached to a cladding tube model was identified during the finite element model optimization process. Unlike a cladding tube model, the density of a fuel rod with pellets cannot be determined in a straightforward manner because pellets do not move in the same phase with the cladding tube motion. The density of a fuel rod with lead pellets was determined by comparing natural frequency ratio between the cladding tube and the rod. Thus, an improved fuel rod finite element model was developed based on the updated cladding tube model and an estimated fuel rod density considering the lead pellets. It is shown that the entire pellet mass does not contribute to the fuel rod dynamics; rather, they are only partially responsible for the fuel rod dynamic behavior.

Algorithms for Ultrasound Elasticity Imaging (초음파 탄성 영상 알고리듬)

  • Kwon, Sung-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.484-493
    • /
    • 2012
  • Since the 1980s, there have been many research activities devoted to quantitatively characterizing and imaging human tissues based on sound speed, attenuation coefficient, density, nonlinear B/A parameter, etc., but those efforts have not yet reached the stage of commercialization. However, a new imaging technology termed elastography, which was proposed in the early 1980s, has recently been implemented in commercial clinical ultrasound scanners, and is now being used to diagnose prostates, breasts, thyroids, livers, blood vessels, etc., more quantitatively as a complementary adjunct modality to the conventional B-mode imaging. The purpose of this article is to introduce and review various elastographic algorithms for use in quasistatic or static compression type elasticity imaging modes. Most of the algorithms are based on the crosscorrelation or autocorrelation function methods, and the fundamental difference is that the time shift is estimated by changing the lag variable in the former, while it is directly obtained from the phase shift at a fixed lag in the latter.

Progressive Collapse of Steel High-Rise Buildings Exposed to Fire: Current State of Research

  • Jiang, Jian;Li, Guo-Qiang
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.375-387
    • /
    • 2018
  • This paper presents a review on progressive collapse mechanism of steel framed buildings exposed to fire. The influence of load ratios, strength of structural members (beam, column, slab, connection), fire scenarios, bracing systems, fire protections on the collapse mode and collapse time of structures is comprehensively reviewed. It is found that the key influencing factors include load ratio, fire scenario, bracing layout and fire protection. The application of strong beams, high load ratios, multi-compartment fires will lead to global downward collapse which is undesirable. The catenary action in beams and tensile membrane action in slabs contribute to the enhancement of structural collapse resistance, leading to a ductile collapse mechanism. It is recommended to increase the reinforcement ratio in the sagging and hogging region of slabs to not only enhance the tensile membrane action in the slab, but to prevent the failure of beam-to-column connections. It is also found that a frame may collapse in the cooling phase of compartment fires or under travelling fires. This is because that the steel members may experience maximum temperatures and maximum displacements under these two fire scenarios. An edge bay fire is more prone to induce the collapse of structures than a central bay fire. The progressive collapse of buildings can be effectively prevented by using bracing systems and fire protections. A combination of horizontal and vertical bracing systems as well as increasing the strength and stiffness of bracing members is recommended to enhance the collapse resistance. A protected frame dose not collapse immediately after the local failure but experiences a relatively long withstanding period of at least 60 mins. It is suggested to use three-dimensional models for accurate predictions of whether, when and how a structure collapses under various fire scenarios.

Antioxidant Potential of Cinnamomum cassia Ethanolic Extract: Identification Of Compounds (계피 에탄올 추출물의 유효성분 분석 및 항산화 효능 평가)

  • Ji Woong Heo;Jae Dong Son;Ye Jin Yang;Min Jung Kim;Ju Hye Yang;Kwang Il Park
    • Herbal Formula Science
    • /
    • v.32 no.3
    • /
    • pp.223-233
    • /
    • 2024
  • Objectives : Natural products containing bioactive compounds with high antioxidant activity are potentially important sources that can contribute to the improvement of various diseases. Therefore, the aim of this study was to investigate phenolic compounds of Cinnamomum cassia (C. cassia) ethanolic extract (CCEE). And then we evaluated the antioxidant effect. Methods : We used liquid chromatography with tandem mass spectrometry (LC-MS/MS) to identify the compounds in CCEE. LC-MS/MS was performed in positive ion mode using Shimadzu, Nexera HPLC system and IDA TOF mass system. Solvent A was distilled water and solvent B was acetonitrile as mobile phase. The analysis was performed at a flow rate of 0.5 ml/min, column temperature of 35 ℃ and wavelength of 284 nm. The antioxidant effect of CCEE was analyzed using DPPH (2,2-diphenyl-2-picrylhydrazyl free radical) and ABTS (2,2'-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid)). In addition, total phenolics and total flavonoids contents were measured to determine antioxidant effects. Results : Analysis using LC-MS/MS identified four compounds: Coumarin, Trans-cinnamaldehyde, Trans-cinnamic acid, and 2-Methoxycinnamaldehyde. Free radicals decreased in a concentration-dependent manner starting from 10 ㎍/ml of CCEE, and decreased to a level similar to Ascorbic acid (AA) from a concentration of 60 ㎍/ml onwards. Conclusions : Based on the findings, CCEE exhibits strong antioxidant activity as evidenced by the presence of Coumarin, Trans-cinnamaldehyde, Trans-cinnamic acid, and 2-Methoxycinnamaldehyde. Consequently, this study suggests that CCEE can serve as an important source of natural antioxidants and can be efficiently used in the management of oxidative stress diseases.

Patterns of Pulsatile and Surge Modes of Follicle-Stimulating Hormone Treated with Different Progesterone Levels in Ovariectomized Goats (난소제거된 Shiba 염소에서 다른 농도의 Progesterone 처치에 의한 FSH Surge 및 Pulse 분비에 미치는 영향)

  • Kim, Seung-Joon;Tanaka, Tomomi;Kamomae, Hideo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.225-231
    • /
    • 2011
  • The objective of the present study was to determine the progesterone levels that effects on the pulsatile and surge modes of FSH secretion. In previous studies we have shown that LH surge occurred in the follicular levels of progesterone, whereas there was no surge mode secretion of LH in either the sub luteal or luteal levels of progesterone. LH pulsatile frequencies were high in two groups such as follicular level and sub luteal level. But in the luteal level of progesterone the pulsatile pattern of LH were strongly suppressed. Namely, sub luteal levels of progesterone, around 1 ng/ml, completely suppressed the LH surge but did not affect the pulsatile frequency of LH secretion. Because of this we hypothesized that the two secretory patterns of FSH are similar to that of LH. Long-term ovariectomized Shiba goats that had received implants of estradiol capsules and three different progesterone silastic packet inducing follicular, subluteal and luteal levels of progesterone were divided into three groups such as non-P, low-P and high-P group. Blood samples were collected daily throughout the experiment for the analysis of gonadal steroid hormone levels and at 10-min intervals for 8 h on Days 0, 3, and 7 (Day 0: just before progesterone treatment) for analysis of the pulsatile frequency of FSH secretion. Then estradiol was infused into the jugular vein of all animals at a rate of 3 ${\mu}/h$ for 16 h on Day 8 to determine whether an FSH surge was induced. Blood samples were collected every 2 h from 4 h before the start of the estradiol infusion until 48 h after the start of the infusion. In each group, the mean ${\pm}$ SEM concentration after progesterone implant treatment was 3.3 ${\pm}$ 0.1 ng/ml for the high P group, 1.1 ${\pm}$ 0.1 ng/ml for the low P group, and < 0.1 ng/ml for the non-P group, concentrations similar to the luteal levels, subluteal levels, and follicular phase levels of the normal estrous cycle, respectively. The FSH pulse frequency was maintained highly in all groups on Day 0, Day 3 and Day 7. An FSH surge was induced in all 4 cases of the Non-P group. In the High P and Low P groups, the plasma concentrations of FSH remained low until 48 h after the start of estradiol infusion, and no occurrence of FSH surge was found in any of the animals. The results of this study not only confirm that the pulsatile patterns of FSH were not inhibited strongly relative to LH, they also suggest that some other mechanism and factor may be controlling the FSH secretion.

Wideband CMOS Voltage-Controlled Oscillator(VCO) for Multi-mode Vehicular Terminal (융복합 차량 수신기를 위한 광대역 전압제어 발진기)

  • Choi, Hyun-Seok;Diep, Bui Quag;Kang, So-Young;Jang, Joo-Young;Bang, Jai-Hoon;Oh, Inn-Yul;Park, Chul-Soon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.63-69
    • /
    • 2008
  • Reconfigurable RF one-chip solutions have been researched with the objective of designing for smaller-sized and more economical RF transceiver and it can be applied to a vehicular wireless terminal. The proposed voltage-controlled oscillator satisfies the targeted frequency range ($4.2{\sim}5.4\;GHz$) and the frequency planning which correspond to the standards such as CDMA(IS-95), PCS, GSM850, EGSM, WCDMA, WLAN, Bluetooth, WiBro, S-DMB, DSRC, GPS, and DVB-H/DMB-H/L(L Band). In order to improve phase noise performance, PMOS is adopted in the cross-coupled pair, the tail current source and MOS varactor in this VCO and differential-typed switching is proposed in capacitor array. Based on the measurement results, a total power dissipation is $5.3{\sim}6.0\;mW$ at 1.8 V power supply voltage. The oscillator is tuned from 4.05 to 5.62 GHz; The tuning range is 33%. The phase noise is -117.16 dBc/Hz at 1 MHz offset frequency and the FOM (Figure Of Merit) is $-180.84{\sim}-180.5$.

  • PDF

Simultaneous analysis of 12 kind maker components in Banhabaekchulchhonma-tang by RP-HPLC (RP-HPLC를 이용한 반하백출천마탕에서 12종 지표성분의 동시분석)

  • Lee, Kwang Jin;Yang, Hye Jin;Ma, Jin Yeul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4682-4691
    • /
    • 2014
  • Banhabaekchulchhonma-tang is a traditional Korean herbal prescription with a range of pharmacological activities. In this study, the simultaneous analysis of 12 kinds of marker components, Homogentisic acid, Hesperidin, Naringin, Alisol A, Atractylenolide II, Atractylenolide III, Ginsenoside Rg1, Formononetin, Gastrodin, Berberine, Palmatine and 6-gingerol, in Banhabaekchulchhonma-tang was performed using high-performance liquid chromatography (RP-HPLC). The standard sample of commercial $C_{18}$ reversed phase-column using water (0.1% TFA) and acetonitrile as the mobile phase with a step gradient elution mode. The flow rate (1.0mL/min), injection volume ($10{\mu}L$) and column oven temperature ($40^{\circ}C$) at a 200, 220, 280 and 340nm wavelength was conducted. All calibration curves of the standard components showed good linearity ($r^2$ >0.999). In addition, the limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.012 to $0.878{\mu}g/mL$ and 0.009 to $0.290{\mu}g/mL$. The precision intra-day and inter-day were ranged from 0.07 to 1.21% and 0.20 to 0.90%, respectively. The recoveries ranged from 97.17 to 108.40%. Each sample amount showed a very small change. These results highlight the efficient quality evaluation of Banhabaekchulchhonma-tang.

The Effect of Au Addition on the Hardening Mechanism in Ag-25wt% Pd-15wt% Cu (Ag-25wt% Pd-15wt% Cu 3원합금(元合金) 및 Au 첨가합금(添加合金)의 시효경화특성(時效京華特性))

  • Bea, B.J.;Lee, H.S.;Lee, K.D.
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.37-49
    • /
    • 1998
  • The specimens used were Ag-25 Pd-15 Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electric furnace and centrifugal casting machine in Ar atmosphere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at $350{\sim}550^{\circ}C$ Age- hardening characteristics of the small Au-containing Ag-Pd-Cu dental alloys were investigated by means of hardness testing. X-ray diffraction and electron microscope observations, electrical resistance, ergy dispersed spectra and electron probe microanalysis. Principal results are as follows : Hardening occured in two stages, i.e., stage I in low temperature and stage II in high temperature regions, during continuous aging. The case of hardening in stage I was due to the formation of the $L1_0$ type face-centered tetragonal PdCu-ordered phase in the grain interior and hardening in stage I was affected by the Cu concentration. In stage II, decomposition of the ${\alpha}$ solid solution to a PdCu ordered phase($L1_0$ type) and an Ag-rich ${\alpha}2$ phase occurred and a discontinuous precipitation occurred at the grain boundary. From the electron microscope study, it was conclued that the cause of age-hardening in this alloy is the precipitation of the PdCu ordered phase, which has AuCu I type face-centered tetragonal structure. Precipetation procedure was ${\alpha}{\to}{\alpha}+{\alpha}_2+PdCu {\to}{\alpha}_1+{\alpha}_2+PdCu$ at Pd/Cu = 1.7 Ag-Pd-Cu alloy is more effective dental alloy as ageing treatment and is suitable to isothermal ageing at $450^{\circ}C$.

  • PDF

The Characteristics of DC-shift in Hybrid Rocket (하이브리드 로켓에서의 DC-shift 발생 특성)

  • Kang, Dong-Hoon;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.456-466
    • /
    • 2010
  • Typical combustion instability such as DC-Shift found in the hybrid rocket motor is characterized by non-linearity. DC-Shift can occur in two different realizations. One is so-called a positive shift of measured DC voltage where the pressure increase suddenly. The other is a negative shift where the pressure drops abruptly. In the present work, specifically the negative DC-Shift was investigated to analyze the effect of oxidizer flow condition and the resonance between fundamental frequency and other ones, such as Helmholtz frequency, and acoustic frequency. Results show a peak frequency of several hundreds HZ shifts as combustion proceeds. A negative DC-shift was found as the result of phase cancellation between two dominant frequency, combustion frequency and flow related frequency. Still is it required to study further to identify the change of dominance of frequency during the combustion.

Development of Polarization-Controllable Active Phased Array Antenna for Receiving Satellite Broadcasting (편파가변 위성 방송 수신용 능동 위상 배열 안테나 개발)

  • Choi, Jin-Young;Lee, Ho-Seon;Kong, Tong-Ook;Chun, Jong-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.325-335
    • /
    • 2018
  • We herein present a study on the active phased array antenna for receiving satellite broadcasting that can electrically align its polarization to that of target transmitters in its moving condition or in the Skew angle arrangement of the broadcasting satellite receiver. Hence, we have developed an active phased array structure composed of the self-developed Vivaldi antenna and multifunction core (MFC) chip, receiving RF front end module, and control units. In particular, the new Vivaldi antenna designed in the Ku-band of 10.7 - 14.5 GHz to receive one desired polarization mode such as the horizontal or vertical by means of an MFC chip and other control units that can control the amplitude and phase of each antenna element. The test results verified that cross-polarization property is 20 dB or higher and the primary beam can be scanned clearly at approximately ${\pm}60^{\circ}$.