Park, Nam-Gyu;Rhee, Hui-Nam;Moon, Hoy-Ik;Jang, Young-Ki;Jeon, Sang-Youn;Kim, Jae-Ik
Nuclear Engineering and Technology
/
v.41
no.6
/
pp.821-830
/
2009
In this paper, modal testing and finite element modeling results to identify the modal parameters of a nuclear fuel rod as well as its cladding tube are discussed. A vertically standing full-size cladding tube and a fuel rod with lead pellets were used in the modal testing. As excessive flow-induced vibration causes a failure in fuel rods, such as fretting wear, the vibration level of fuel rods should be low enough to prevent failure of these components. Because vibration amplitude can be estimated based on the modal parameters, the dynamic characteristics must be determined during the design process. Therefore, finite element models are developed based on the test results. The effect of a lumped mass attached to a cladding tube model was identified during the finite element model optimization process. Unlike a cladding tube model, the density of a fuel rod with pellets cannot be determined in a straightforward manner because pellets do not move in the same phase with the cladding tube motion. The density of a fuel rod with lead pellets was determined by comparing natural frequency ratio between the cladding tube and the rod. Thus, an improved fuel rod finite element model was developed based on the updated cladding tube model and an estimated fuel rod density considering the lead pellets. It is shown that the entire pellet mass does not contribute to the fuel rod dynamics; rather, they are only partially responsible for the fuel rod dynamic behavior.
Journal of the Korean Society for Nondestructive Testing
/
v.32
no.5
/
pp.484-493
/
2012
Since the 1980s, there have been many research activities devoted to quantitatively characterizing and imaging human tissues based on sound speed, attenuation coefficient, density, nonlinear B/A parameter, etc., but those efforts have not yet reached the stage of commercialization. However, a new imaging technology termed elastography, which was proposed in the early 1980s, has recently been implemented in commercial clinical ultrasound scanners, and is now being used to diagnose prostates, breasts, thyroids, livers, blood vessels, etc., more quantitatively as a complementary adjunct modality to the conventional B-mode imaging. The purpose of this article is to introduce and review various elastographic algorithms for use in quasistatic or static compression type elasticity imaging modes. Most of the algorithms are based on the crosscorrelation or autocorrelation function methods, and the fundamental difference is that the time shift is estimated by changing the lag variable in the former, while it is directly obtained from the phase shift at a fixed lag in the latter.
This paper presents a review on progressive collapse mechanism of steel framed buildings exposed to fire. The influence of load ratios, strength of structural members (beam, column, slab, connection), fire scenarios, bracing systems, fire protections on the collapse mode and collapse time of structures is comprehensively reviewed. It is found that the key influencing factors include load ratio, fire scenario, bracing layout and fire protection. The application of strong beams, high load ratios, multi-compartment fires will lead to global downward collapse which is undesirable. The catenary action in beams and tensile membrane action in slabs contribute to the enhancement of structural collapse resistance, leading to a ductile collapse mechanism. It is recommended to increase the reinforcement ratio in the sagging and hogging region of slabs to not only enhance the tensile membrane action in the slab, but to prevent the failure of beam-to-column connections. It is also found that a frame may collapse in the cooling phase of compartment fires or under travelling fires. This is because that the steel members may experience maximum temperatures and maximum displacements under these two fire scenarios. An edge bay fire is more prone to induce the collapse of structures than a central bay fire. The progressive collapse of buildings can be effectively prevented by using bracing systems and fire protections. A combination of horizontal and vertical bracing systems as well as increasing the strength and stiffness of bracing members is recommended to enhance the collapse resistance. A protected frame dose not collapse immediately after the local failure but experiences a relatively long withstanding period of at least 60 mins. It is suggested to use three-dimensional models for accurate predictions of whether, when and how a structure collapses under various fire scenarios.
Ji Woong Heo;Jae Dong Son;Ye Jin Yang;Min Jung Kim;Ju Hye Yang;Kwang Il Park
Herbal Formula Science
/
v.32
no.3
/
pp.223-233
/
2024
Objectives : Natural products containing bioactive compounds with high antioxidant activity are potentially important sources that can contribute to the improvement of various diseases. Therefore, the aim of this study was to investigate phenolic compounds of Cinnamomum cassia (C. cassia) ethanolic extract (CCEE). And then we evaluated the antioxidant effect. Methods : We used liquid chromatography with tandem mass spectrometry (LC-MS/MS) to identify the compounds in CCEE. LC-MS/MS was performed in positive ion mode using Shimadzu, Nexera HPLC system and IDA TOF mass system. Solvent A was distilled water and solvent B was acetonitrile as mobile phase. The analysis was performed at a flow rate of 0.5 ml/min, column temperature of 35 ℃ and wavelength of 284 nm. The antioxidant effect of CCEE was analyzed using DPPH (2,2-diphenyl-2-picrylhydrazyl free radical) and ABTS (2,2'-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid)). In addition, total phenolics and total flavonoids contents were measured to determine antioxidant effects. Results : Analysis using LC-MS/MS identified four compounds: Coumarin, Trans-cinnamaldehyde, Trans-cinnamic acid, and 2-Methoxycinnamaldehyde. Free radicals decreased in a concentration-dependent manner starting from 10 ㎍/ml of CCEE, and decreased to a level similar to Ascorbic acid (AA) from a concentration of 60 ㎍/ml onwards. Conclusions : Based on the findings, CCEE exhibits strong antioxidant activity as evidenced by the presence of Coumarin, Trans-cinnamaldehyde, Trans-cinnamic acid, and 2-Methoxycinnamaldehyde. Consequently, this study suggests that CCEE can serve as an important source of natural antioxidants and can be efficiently used in the management of oxidative stress diseases.
The objective of the present study was to determine the progesterone levels that effects on the pulsatile and surge modes of FSH secretion. In previous studies we have shown that LH surge occurred in the follicular levels of progesterone, whereas there was no surge mode secretion of LH in either the sub luteal or luteal levels of progesterone. LH pulsatile frequencies were high in two groups such as follicular level and sub luteal level. But in the luteal level of progesterone the pulsatile pattern of LH were strongly suppressed. Namely, sub luteal levels of progesterone, around 1 ng/ml, completely suppressed the LH surge but did not affect the pulsatile frequency of LH secretion. Because of this we hypothesized that the two secretory patterns of FSH are similar to that of LH. Long-term ovariectomized Shiba goats that had received implants of estradiol capsules and three different progesterone silastic packet inducing follicular, subluteal and luteal levels of progesterone were divided into three groups such as non-P, low-P and high-P group. Blood samples were collected daily throughout the experiment for the analysis of gonadal steroid hormone levels and at 10-min intervals for 8 h on Days 0, 3, and 7 (Day 0: just before progesterone treatment) for analysis of the pulsatile frequency of FSH secretion. Then estradiol was infused into the jugular vein of all animals at a rate of 3 ${\mu}/h$ for 16 h on Day 8 to determine whether an FSH surge was induced. Blood samples were collected every 2 h from 4 h before the start of the estradiol infusion until 48 h after the start of the infusion. In each group, the mean ${\pm}$ SEM concentration after progesterone implant treatment was 3.3 ${\pm}$ 0.1 ng/ml for the high P group, 1.1 ${\pm}$ 0.1 ng/ml for the low P group, and < 0.1 ng/ml for the non-P group, concentrations similar to the luteal levels, subluteal levels, and follicular phase levels of the normal estrous cycle, respectively. The FSH pulse frequency was maintained highly in all groups on Day 0, Day 3 and Day 7. An FSH surge was induced in all 4 cases of the Non-P group. In the High P and Low P groups, the plasma concentrations of FSH remained low until 48 h after the start of estradiol infusion, and no occurrence of FSH surge was found in any of the animals. The results of this study not only confirm that the pulsatile patterns of FSH were not inhibited strongly relative to LH, they also suggest that some other mechanism and factor may be controlling the FSH secretion.
The Journal of The Korea Institute of Intelligent Transport Systems
/
v.7
no.6
/
pp.63-69
/
2008
Reconfigurable RF one-chip solutions have been researched with the objective of designing for smaller-sized and more economical RF transceiver and it can be applied to a vehicular wireless terminal. The proposed voltage-controlled oscillator satisfies the targeted frequency range ($4.2{\sim}5.4\;GHz$) and the frequency planning which correspond to the standards such as CDMA(IS-95), PCS, GSM850, EGSM, WCDMA, WLAN, Bluetooth, WiBro, S-DMB, DSRC, GPS, and DVB-H/DMB-H/L(L Band). In order to improve phase noise performance, PMOS is adopted in the cross-coupled pair, the tail current source and MOS varactor in this VCO and differential-typed switching is proposed in capacitor array. Based on the measurement results, a total power dissipation is $5.3{\sim}6.0\;mW$ at 1.8 V power supply voltage. The oscillator is tuned from 4.05 to 5.62 GHz; The tuning range is 33%. The phase noise is -117.16 dBc/Hz at 1 MHz offset frequency and the FOM (Figure Of Merit) is $-180.84{\sim}-180.5$.
Journal of the Korea Academia-Industrial cooperation Society
/
v.15
no.7
/
pp.4682-4691
/
2014
Banhabaekchulchhonma-tang is a traditional Korean herbal prescription with a range of pharmacological activities. In this study, the simultaneous analysis of 12 kinds of marker components, Homogentisic acid, Hesperidin, Naringin, Alisol A, Atractylenolide II, Atractylenolide III, Ginsenoside Rg1, Formononetin, Gastrodin, Berberine, Palmatine and 6-gingerol, in Banhabaekchulchhonma-tang was performed using high-performance liquid chromatography (RP-HPLC). The standard sample of commercial $C_{18}$ reversed phase-column using water (0.1% TFA) and acetonitrile as the mobile phase with a step gradient elution mode. The flow rate (1.0mL/min), injection volume ($10{\mu}L$) and column oven temperature ($40^{\circ}C$) at a 200, 220, 280 and 340nm wavelength was conducted. All calibration curves of the standard components showed good linearity ($r^2$ >0.999). In addition, the limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.012 to $0.878{\mu}g/mL$ and 0.009 to $0.290{\mu}g/mL$. The precision intra-day and inter-day were ranged from 0.07 to 1.21% and 0.20 to 0.90%, respectively. The recoveries ranged from 97.17 to 108.40%. Each sample amount showed a very small change. These results highlight the efficient quality evaluation of Banhabaekchulchhonma-tang.
The specimens used were Ag-25 Pd-15 Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electric furnace and centrifugal casting machine in Ar atmosphere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at $350{\sim}550^{\circ}C$ Age- hardening characteristics of the small Au-containing Ag-Pd-Cu dental alloys were investigated by means of hardness testing. X-ray diffraction and electron microscope observations, electrical resistance, ergy dispersed spectra and electron probe microanalysis. Principal results are as follows : Hardening occured in two stages, i.e., stage I in low temperature and stage II in high temperature regions, during continuous aging. The case of hardening in stage I was due to the formation of the $L1_0$ type face-centered tetragonal PdCu-ordered phase in the grain interior and hardening in stage I was affected by the Cu concentration. In stage II, decomposition of the ${\alpha}$ solid solution to a PdCu ordered phase($L1_0$ type) and an Ag-rich ${\alpha}2$ phase occurred and a discontinuous precipitation occurred at the grain boundary. From the electron microscope study, it was conclued that the cause of age-hardening in this alloy is the precipitation of the PdCu ordered phase, which has AuCu I type face-centered tetragonal structure. Precipetation procedure was ${\alpha}{\to}{\alpha}+{\alpha}_2+PdCu {\to}{\alpha}_1+{\alpha}_2+PdCu$ at Pd/Cu = 1.7 Ag-Pd-Cu alloy is more effective dental alloy as ageing treatment and is suitable to isothermal ageing at $450^{\circ}C$.
Journal of the Korean Society for Aeronautical & Space Sciences
/
v.38
no.5
/
pp.456-466
/
2010
Typical combustion instability such as DC-Shift found in the hybrid rocket motor is characterized by non-linearity. DC-Shift can occur in two different realizations. One is so-called a positive shift of measured DC voltage where the pressure increase suddenly. The other is a negative shift where the pressure drops abruptly. In the present work, specifically the negative DC-Shift was investigated to analyze the effect of oxidizer flow condition and the resonance between fundamental frequency and other ones, such as Helmholtz frequency, and acoustic frequency. Results show a peak frequency of several hundreds HZ shifts as combustion proceeds. A negative DC-shift was found as the result of phase cancellation between two dominant frequency, combustion frequency and flow related frequency. Still is it required to study further to identify the change of dominance of frequency during the combustion.
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.29
no.5
/
pp.325-335
/
2018
We herein present a study on the active phased array antenna for receiving satellite broadcasting that can electrically align its polarization to that of target transmitters in its moving condition or in the Skew angle arrangement of the broadcasting satellite receiver. Hence, we have developed an active phased array structure composed of the self-developed Vivaldi antenna and multifunction core (MFC) chip, receiving RF front end module, and control units. In particular, the new Vivaldi antenna designed in the Ku-band of 10.7 - 14.5 GHz to receive one desired polarization mode such as the horizontal or vertical by means of an MFC chip and other control units that can control the amplitude and phase of each antenna element. The test results verified that cross-polarization property is 20 dB or higher and the primary beam can be scanned clearly at approximately ${\pm}60^{\circ}$.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.