The Journal of the Convergence on Culture Technology
/
v.8
no.5
/
pp.1-7
/
2022
Korean medical device industry has laid the foundation for full-fledged growth and development with the G7 medical engineering technology development project that started in 1995, and the medical device production in 2020 increased by 8.52 times and the export by 13.94 times, compared to those in 2001. In early years, electronic medical devices such as ultrasound imaging device contributed greatly to Korean medical industry, but top ranks in medical device production and export in Korea has shifted recently to in vitro diagnostic medical devices and dental implants. However, the share of imported medical devices in the Korean medical device market have not changed much; it still ranges in 60 to 70%, as the Korean medical device industry produces and exports mid- to low-priced medical devices, and technology-intensive and capital-intensive high-priced medical devices are mainly imported. In this paper, we compare the leading medical devices produced by major Korean companies and those by global top medical device companies to suggest strategies for the Korean medical device companies to enter the global market.
Background: The coronavirus disease 2019 pandemic has been challenging the healthcare service, i.e., the vitalization of the point of care accompanying self-testing in vitro diagnostic medical devices (IVDs). This study aims to suggest priority criteria to classify self-testing IVDs using the analytic hierarchy process technique. Methods: Two dimensions of the characteristics embedded in the IVDs and the diseases to be diagnosed with self-testing IVDs were parallelly considered and independently investigated. In addition, three expert panels consisting of laboratory medical doctors (n=11), clinicians (n=10), and citizens (n=11) who have an interest in the selection of self-testing IVDs were asked to answer to questionnaires. Priorities were derived and compared among each expert panel. Results: First of all, ease of specimen collection (0.241), urgency of the situation (0.224), and simplicity of device operation (0.214) were found to be the most important criteria in light of the functional characteristics of self-testing IVDs. Medical doctors valued the ease of specimen collection, but the citizen's panel valued self-management of the disease more. Second, considering the characteristics of the diseases, the priority criteria were shown in the order of prevalence of diseases (0.421), fatality of disease (0.378), and disease with stigma (0.201). Third, medical doctors responded that self-testing IVDs were more than twice as suitable for non-communicable diseases as compared to communicable diseases (0.688 vs. 0.312), but the citizen's group responded that self-testing IVDs were slightly more suitable for infectious diseases (0.511 vs. 0.489). Conclusion: Our findings suggested that self-testing IVDs could be primarily classified as the items for diagnosis of non-communicable diseases for the purpose of self-management with easy specimen collection and simple operation of devices, taking into account the urgency of the situation as well as prevalence and fatality of the disease.
An, Hyo-Jin;Yoon, Hyang-Jin;Kim, Chung-Hyun;Wee, Sung-Hwan;Moon, Jin-San
Korean Journal of Veterinary Research
/
v.55
no.2
/
pp.97-103
/
2015
In this study, the Korean veterinary medical devices management system was evaluated relative to systems in the USA, EU, and Japan. Veterinary medical devices are regulated in Korea based on the Medical Appliance Act of 1997. This was initially supervised by the Ministry of Agriculture, Food and Rural Affairs and Korea Animal Health Products Association, and subsequently by the Animal and Plant Quarantine Agency (QIA) in 2000. These devices were classified approximately 1,400 categories as instruments, supplies, artificial insemination apparatus, and other categories. Each of these devices was assigned to four regulatory grades by the QIA in 2007. The ranking system for veterinary medical devices was implemented in 2014 with 820 products from 162 companies registered by that year. However, in vitro diagnostic devices (IVDDs) for animals were managed as medical devices and biological medicine. In vitro diagnostic reagents for treating infection diseases are not subjected to either a classification or grading system. Veterinary medical devices are currently exempt from good manufacturing practices (GMP) and device tracking requirements. Due to gradual growth of the domestic veterinary medical devices market since 2008, regulation of these devices should be improved with re-examination of IVDDs and GMP certification for the effective operating system.
Journal of the Korean institute of surface engineering
/
v.55
no.6
/
pp.390-397
/
2022
Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.
KIPS Transactions on Computer and Communication Systems
/
v.12
no.2
/
pp.77-84
/
2023
Dengue virus transmission is a viral infection disease between humans and Aedes mosquitoes. Dengue is ubiquitous throughout the tropics and subtropical zones, where 1/3 of the global population live. The weather in Korea is also changing to subtropical weather, resulting in increased vulnerable Korean population to dengue virus transmission. It is important to control and prevent the dengue risk with track-recording & monitoring system. It is also required to have the control system to treat and monitor dengue patients with various cases such as regions, ages, genders according to the track-record of the disease. In this paper, we developed a Dengue Control & Prevention System, which can monitor and control dengue outbreaks in real-time with in-vitro diagnostic devices. Dengue Control & Prevention System is composed of in-vitro diagnostic device, which is a fluorescent immunoassay, and real-time monitoring system. In the future, we expect that our Dengue Control & Prevention System can be upgraded to have various disease information from Korea Disease Control and Prevention Agency for government policies and diseases control in Korea.
EN ISO 14971:2012 a risk management standard approved and applied as a European standard in 2012, will be adopted and applied as ISO 14971:2019 published in December 2019, ISO/TR 24971(Guidance) published in June 2020 from May 2022. After that, it is applied to IVDD surveillance and IVDR new and conversion, and the manufacturer is already preparing for application or is starting preparation for application. In addition, 98/78/EEC IVDD applied from 1998 will also be applied as REGULATION (EU) 2017/746 IVDR from May 2022. In particular, in IVDR, the requirements for post-marketing investigations such as Post Market Surveillance (PMS), Summary of safety and performance(SSP), Periodic Safety Update Report(PSUR) and Post Market Performance Follow Up(PMPF), which were not required in the existing IVDD, increased, and the contents were also specified. This study focused on ISO14971:2019 among these strengthened and newly applied regulations, and tried to present a detailed analysis and application plan of Post Market Surveillance (PMS) required by 2017/746 IVDR.
Well-established standards and specifications for medical devices not only provide clarity and consistency in licensing processes but also secure device safety and effectiveness. This study reviewed regulatory standards and specifications for veterinary medical devices in Korea based on data obtained through analyses of those medical devices. General standards for electromechanical, electromagnetic, and biological safety and individual standards for 76 electric and 70 general medical device products have been established by the Korean Ministry of Food and Drug Safety. However, the first standards and specifications for veterinary medical devices were established in March 2000 for two products (disposable needle and syringe). Similar to the large number of standards for medical devices, there have been general standards for safety and individual standards for 72 veterinary medical devices (27 electric medical devices, 12 non-electric medical devices, 10 medical supplies, and 23 other types) established since 2014. These new standards considered, among other aspects, the devices' applications, usage characteristics, and industrial environment. To date, the establishment of standards and specifications for veterinary medical devices remains limited. This study suggests that improvements should be made to the regulation of general and individual standards associated with various veterinary medical instruments, supplies, and in vitro diagnostic medical reagents.
In this paper, basic study of diagnostic device development for early detection of cancer, we present the optical property measurements of 12 histologically classified biological tissue and blood specimens in order to determine whether significant optical contrast exists for detection of disease(cancer). In vitro, optical properties of each 630nm, 660nm, 780n, 880nm and 940nm shows consistent changes in effective absorbtion coefficients, ${\mu}$$\_$${\alpha}$/ with tissue classification of pig an chicken and human blood according to the 27.3%, 35.4%, 45.6% and 59.1% of HCT. We found differences in optical properties at each of specific wavelengths and histologically classified biological tissue.
Purpose: Hysteroscopy can be used both to diagnose and to treat intrauterine pathologies. It is well known that hysteroscopy helps to improve reproductive outcomes by treating intrauterine pathologies. However, it is uncertain whether hysteroscopy is helpful in the absence of intrauterine pathologies. This study aimed to confirm whether hysteroscopy improves the reproductive outcomes of infertile women without intrauterine pathologies. Methods: We conducted a systematic review of 11 studies retrieved from Ovid-MEDLINE, Ovid-Embase, and the Cochrane Library. Two independent investigators extracted the data and used risk-of-bias tools (RoB 2.0 and ROBINS-I) to assess their quality. Results: Diagnostic hysteroscopy prior to in vitro fertilization (IVF)/intracytoplasmic sperm injection (ICSI) was associated with a higher clinical pregnancy rate (CPR) and live birth rate (LBR) than non-hysteroscopy in patients with recurrent implantation failure (RIF) (odds ratio, 1.79 and 1.46; 95% confidence interval, 1.40-2.30 and 1.08-1.97 for CPR and LBR, respectively) while hysteroscopy prior to first IVF was ineffective. The overall meta-analysis of LBR showed statistically significant findings for RIF, but a subgroup analysis showed effects only in prospective cohorts (odds ratio, 1.40 and 1.47; 95% confidence interval, 0.62-3.16 and 1.04-2.07 for randomized controlled trials and prospective cohorts, respectively). Therefore, the LBR should be interpreted carefully and further research is needed. Conclusion: Although further research is warranted, hysteroscopy may be considered as a diagnostic and treatment option for infertile women who have experienced RIF regardless of intrauterine pathologies. This finding enables nurses to educate and support infertile women with RIF prior to IVF/ICSI.
Purpose: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. Materials and Methods: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. Results: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. Conclusion: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.