• Title/Summary/Keyword: In Ground Effect

Search Result 3,793, Processing Time 0.036 seconds

Seismic responses of a metro tunnel in a ground fissure site

  • Liu, Nina;Huang, Qiang-Bing;Fan, Wen;Ma, Yu-Jie;Peng, Jian-Bing
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.775-781
    • /
    • 2018
  • Shake table tests were conducted on scaled tunnel model to investigate the mechanism and effect of seismic loadings on horseshoe scaled tunnel model in ground fissure site. Key technical details of the experimental test were set up, including similarity relations, boundary conditions, sensor layout, modelling methods were presented. Synthetic waves and El Centro waves were adopted as the input earthquake waves. Results measured from hanging wall and foot wall were compared and analyzed. It is found that the seismic loadings increased the subsidence of hanging wall and lead to the appearance and propagation of cracks. The values of acceleration, earth pressure and strain were greater in the hanging wall than those in the foot wall. The tunnel exhibited the greatest earth pressure on right and left arches, however, the earth pressure on the crown of arch is the second largest and the inverted arch has the least earth pressure in the same tunnel section. Therefore, the effect of the hanging wall on the seismic performance of metro tunnel in earth fissure ground should be considered in the seismic design.

Effect of interference and Ground Movement by Twin Tunnelling (쌍굴터널 굴진에 따른 주변지반의 거동과 간섭효과)

  • 김학문
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.136-142
    • /
    • 1997
  • The behaviour of ground movement during the construction of two parallel tunnels in weathered zone and soft rock has been investigated. All the influencing factors for the behaviour of twin tunnel such as tunnel size, ground conditions, tunnel depth, pillar width and initial state of ground stresses were examined The results of FEM nonlinear analysis were compared with some of model test results in weathered zone to verify the numerical method. It was found that minimum interference was obtained in the parallel construction case when the twin tunnel distance (pillar width) is just over the twice of tunnel diameter. Guide line for the interference of twin tunnelling has been introduced for the ground of weathered zone and soft rock.

  • PDF

Variation of fisheries conditions of mackerel (Scomber japonicus) fishing ground for large purse seine fisheries (대형선망어업에 있어서 고등어 (Scomber japonicus) 어장의 어황변동)

  • Lee, Haet-Nim;Kim, Hyung-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.2
    • /
    • pp.108-117
    • /
    • 2011
  • In order to offer data about fisheries resources management and prediction of catch on large purse seine fisheries, the fluctuation of the fisheries condition and distributions of fishing ground for mackerel were analysed with monthly catch data for 1990.2009. The overall catch has decreased to about 70% since 1997, with approximately 70% of the mackerel (Scomber japonicus) catch and monthly fluctuations showing a similar pattern. Monthly distribution of fishing ground is like distribution of mackerel in large purse seine fishery. The main fishing grounds are near Jeju Island and the Yellow sea with the main fishing season existing between October to December. The catches fluctuations and distribution of fishing ground were related to the effect of regime shifts. Therefore, in order to prediction of catch on large purse seine fisheries should be studied these relationships.

a study on ground improvement of sandy soil by CGS Method (압밀주입에 의한 지반개량 특성고찰)

  • Gwak, Soo-Jeong;Baek, Hong-Ryul
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.185-192
    • /
    • 2006
  • In this study the case of ground improvement by CGS as injection method were analyzed in order to find out effect of behavior of sandy soil and the application of this method as ground improvement. The study were analyzed N value after CGS work of sandy soil by many sites test. Considering that increase of N value, CGS can be considered as an effective method to increase the bear capacity as well as constrain the settlement of soft ground From the results of this study, N value after CGS work of sandy soil were closed to N value of ground and relative density(Dr), improvement ratio(As) of grouting and the study will be done continuously for finding out relation of them

  • PDF

Experimental Study on the Seismic Structural Responses Subjected to Different Earthquakes (지진특성에 따른 구조물의 지진응답실험)

  • 최인길;김형규;김민규;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.82-89
    • /
    • 2003
  • Near-field ground motions exhibit special characteristics that are different from ordinary far-field ground motions. In this study the shaking table tests were conducted to evaluate the effect of earthquake ground motions with different characteristics on the response of the structure. The ground motions used in this study were the scenario earthquake, design earthquake, and Chi-Chi earthquake measured in TCU052 station. These earthquakes have different frequency contents. The test results show that the frequency content of ground motion is very important to the response of structures. The floor responses of structure were greatly affected by the higher modal frequencies, as well as the fundamental frequency. The responses of third floor were significantly reduced due to the interaction between the structure and the base isolated mass installed at the third floor.

  • PDF

Estimation of floor response spectra induced by artificial and real earthquake ground motions

  • Pu, Wuchuan;Xu, Xi
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.377-390
    • /
    • 2019
  • A method for estimating the floor response spectra (FRS) of elastic structures under earthquake excitations is proposed. The method is established based on a previously proposed direct estimation method for single degree of freedom systems, which generally overestimates the FRS of a structure, particularly in the resonance period range. A modification factor is introduced to modify the original method; the modification factor is expressed as a function of the period ratio and is determined through regression analysis on time history analysis results. Both real and artificial ground motions are considered in the analysis, and it is found that the modification factors obtained from the real and artificial ground motions are significantly different. This suggests that the effect of ground motion should be considered in the estimation of FRS. The modified FRS estimation method is further applied to a 10-story building structure, and it is verified that the proposed method can lead to a good estimation of FRS of multi-story buildings.

Duration Effect of the Ground Motion on Structures (지반거동의 지속시간이 건물에 미치는 영향)

  • 김희철
    • Computational Structural Engineering
    • /
    • v.5 no.1
    • /
    • pp.91-96
    • /
    • 1992
  • Earthquake resistant design is evolutionary, and, although great progress has been made since seismic design was made mandatory by building codes, it is still not completely understood. In this paper, a 10 story steel building is analyzed and its results are compared by applying two different actual ground motions to the structure. 12 sets of Loma Prieta, California, earthquake data which occurred in 1989, and recorded 7.1 on the Richter scale and 9 sets of Valparaiso, Chile, earthquake data which occurred in 1985, and recorded 7.8 on the Richter scale were scaled to zone 2B level of UBC-88. By applying earthquake ground motions which had similar Richter scale magnitude, it was found that the Chile earthquake which had long duration of ground motion affected about twice bigger than that of California earthquake which had relatively short duration of ground motion. In addition to the peak ground motion, the duration of the ground motion is a very important factor in structural design.

  • PDF

Effect of near and far-field earthquakes on RC bridge with and without damper

  • Soureshjani, Omid Karimzade;Massumi, Ali
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.533-543
    • /
    • 2019
  • This paper presents a study on the behavior of an RC bridge under near-field and far-field ground motions. For this purpose, a dynamic nonlinear finite element time history analysis has been conducted. The near-field and far-field records are chosen pairwise from the same events which are fits to the seismic design of the bridge. In order to perform an accurate seismic evaluation, the model has been analyzed under two vertical and horizontal components of ground motions. Parameters of relative displacement, residual displacement, and maximum plastic strain have been considered and compared in terms of near-field and far-field ground motions. In the following, in order to decrease the undesirable effects of near-field ground motions, a viscous damper is suggested and its effects have been studied. In this case, the results show that the near-field ground motions increase maximum relative and residual displacement respectively up to three and twice times. Significant seismic improvements were achieved by using viscous dampers on the bridge model. Somehow under the considered near-field ground motion, parameters of residual and relative displacement decrease dramatically even less than the model without damper under the far-field record of the same ground motion.

A Study on the Distribution Stresses beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers (연약점토층위 이층지반 지표면 재하시 지중응력 특성연구)

  • Lee, In-Hyung;Lim, Jong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.47-57
    • /
    • 2005
  • Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research presents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer fur its vertical and horizontal stresses in (1) homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stresses fumed out to be different in the value of theoretical and actual measurement after the trial examination of model. This study has the purpose of suggesting the better construction method of running equipment on weak stratum by comparing the estimated value of trial experiment and theory on underground stress of the weak ground surface area and of raising up the necessity of the continuous research hereafter.