• Title/Summary/Keyword: In - Plane Loads

Search Result 422, Processing Time 0.027 seconds

Dynamic Responses on Semi-Infinite Space Due to Transient Line Source in Orthotropic Media (선형하중에 의한 직교이방성 매체의 반구계에서 동적 응답 특성)

    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.974-980
    • /
    • 1998
  • The analysis of dynamic responses are carried out on several orthotropic systems due to transient line source. These include infinite and semi-infinite spaces. The media possess orthotropic or higher symmetry. The lode is in the form of a normal stress acting with parallel to symmetry axis on the plane of symmetry within the materials. The results are first derived for responses of infinite media due to a harmonic line source. Subsequently the results for semi-infinite are derived by using superposition of the solution in the infinite medium together with a scattered solution from the boundaries. The sum of both solutions has to satisfy stress free boundary conditions thereby leading to the complete solutions. Explicit splutions for the displacements due to transient line loads are then obtaind by using Cargniard-DeHoop contour.

  • PDF

Seismic Performance Enhancement of Building Structures with Beam-end Rotation Type Dampers (보단부 회전형감쇠기를 이용한 건축구조물의 내진성능보강)

  • Woo, Sung-Sik;Lee, Sang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.589-597
    • /
    • 2008
  • The vertical extension of a building in general remodeling process increases both gravity and seismic loads by simply adding masses to the building. In this study, a vertical extension structural module(VESM) is proposed for enhancing seismic performance of the existing buildings by utilizing the story-increased parts. The proposed VESM is composed of steel column, steel beam, and beam-end rotational damper. The steel columns are connected to the shear walls and transfer the wall rotation in out-of plane to the steel beam, and then the beam-end rotational damper dissipates the earthquake-induced energy. Numerical analysis result from a cantilever beam of which end-rotation is restricted by rotational damper indicates that the displacement, base shear, and base overturning moment of the existing structures showing cantilever behavior can be significantly reduced by using the proposed method. Also, it is observed that friction-type rotational damper is effective than viscous one.

Physical stability response of a SLGS resting on viscoelastic medium using nonlocal integral first-order theory

  • Rouabhia, Abdelkrim;Chikh, Abdelbaki;Bousahla, Abdelmoumen Anis;Bourada, Fouad;Heireche, Houari;Tounsi, Abdeldjebbar;Kouider Halim, Benrahou;Tounsi, Abdelouahed;Al-Zahrani, Mesfer Mohammad
    • Steel and Composite Structures
    • /
    • v.37 no.6
    • /
    • pp.695-709
    • /
    • 2020
  • The buckling properties of a single-layered graphene sheet (SLGS) are examined using nonlocal integral first shear deformation theory (FSDT) by incorporating the influence of visco-Pasternak's medium. This model contains only four variables, which is even less than the conventional FSDT. The visco-Pasternak's medium is introduced by considering the damping influence to the conventional foundation model which modeled by the linear Winkler's coefficient and Pasternak's (shear) foundation coefficient. The nanoplate under consideration is subjected to compressive in- plane edge loads per unit length. The impacts of many parameters such as scale parameter, aspect ratio, the visco-Pasternak's coefficients, damping parameter, and mode numbers on the stability investigation of the SLGSs are examined in detail. The obtained results are compared with the corresponding available in the literature.

Effect of flexure-extension coupling on the elastic instability of a composite laminate plate

  • H. Mataich;A. El Amrani;J. El Mekkaoui;B. El Amrani
    • Structural Engineering and Mechanics
    • /
    • v.90 no.4
    • /
    • pp.391-401
    • /
    • 2024
  • The present study focuses on the effect of extension-bending coupling on the elastic stability (buckling) of laminated composite plates. These plates will be loaded under uni-axial or bi-axial in-plane mechanical loads, especially in the orthotropic or anti-symmetric cross-angle cases. The main objective is to find a limit where we can approximate the elastic stability behavior of angularly crossed anti-symmetric plates by the simple behavior of specially orthotropic plates. The contribution of my present study is to predict the explicit effect of extension-flexion coupling on the elastic stability of this type of panel. Critically, a parametric study is carried out, involving the search for the critical buckling load as a function of deformation mode, aspect ratio, plate anisotropy ratio and finally the study of the effect of lamination angle and number of layers on the contribution of extension-flexure coupling in terms of plate buckling stability. We use first-order shear deformation theory (FSDT) with a correction factor of 5/6. Simply supported conditions along the four boundaries are adopted where we can develop closed-form analytical solutions obtained by a Navier development.

Half-Scaled Substructure Test of a Transmission Tower Using Actuators (엑츄에이터를 이용한 송전철탑의 1/2 축소부분실험)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.178-188
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, it was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

  • PDF

Study on thermal buckling and post-buckling behaviors of FGM tubes resting on elastic foundations

  • She, Gui-Lin;Ren, Yi-Ru;Xiao, Wan-Shen;Liu, Haibo
    • Structural Engineering and Mechanics
    • /
    • v.66 no.6
    • /
    • pp.729-736
    • /
    • 2018
  • This paper studies thermal buckling and post-buckling behaviors of functionally graded materials (FGM) tubes subjected to a uniform temperature rise and resting on elastic foundations via a refined beam model. Compared to the Timoshenko beam theory, the number of unknowns of this model are the same and no correction factors are required. The material properties of the FGM tube vary continuously in the radial direction according to a power function. Two ends of the tube are assumed to be simply supported and in-plane boundary conditions are immovable. Energy variation principle is employed to establish the governing equations. A two-step perturbation method is adopted to determine the critical thermal buckling loads and post-buckling paths of the tubes with arbitrary radial non-homogeneity. Through detailed parametric studies, it can be found that the tube has much higher buckling temperature and post-buckling strength when it is supported by an elastic foundation.

Development of Mandrel Forging Process for Large Conical Aluminum Shell (대형 원뿔형 알루미늄 실린더의 멘드렐 단조 공정 개발)

  • Nam, J.W.;Cho, J.R.;Lee, K.H.;Lee, I.H.
    • Transactions of Materials Processing
    • /
    • v.27 no.5
    • /
    • pp.276-280
    • /
    • 2018
  • This paper has developed a forging process for conical shells for making aluminum cylindrical large shells. An incremental forging process was applied to reduce forging loads and die cost. The preform is designed based on the crosssectional area of the final forged shape. Inner diameter of the preform for mandrel forging is constant, and outer diameter is conical so that it matches the cross-sectional area of the product. However, simulation confirmed that the larger diameter is smaller than predicted and the length is larger than predicted because in the initial stage of forging, the large diameter portion first comes into contact with the anvil at the initial stage of forging and stretches in longitudinal direction. So, it has developed a rule to design the preform considering 3-D deformation instead of plane strain deformation at the beginning stage of mandrel forging. The developed mandrel forging process can be applied to more similar products and economic benefits may be obtained.

Ground Vibration Analysis for Light Rail Transit on Bridges (교량구간에서의 경량전철에 의한 지반진동 해석)

  • 김두기;이종재;윤정방;김두훈
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.71-82
    • /
    • 2000
  • Ground vibration analysis methods for Light Rail Transit(LRT) on bridges are studied. LRT loads acting on the piers are evaluated considering interactions between trains and a bridge. Two dimensional in-plane and axisymmetric wave propagations are used in ground vibration analyses, and then the results of them are compared one another. A modified axisymmetric method is presented, which can consider the effect of the train loadings on a series of piers as the train moves. Parametric studies are carried out for various train speeds, bridge types and geotechnical conditions to investigate the characteristics of ground vibrations.

  • PDF

Point load actuation on plate structures based on triangular piezoelectric patches

  • Tondreau, Gilles;Raman, Sudharsana Raamanujan;Deraemaeker, Arnaud
    • Smart Structures and Systems
    • /
    • v.13 no.4
    • /
    • pp.547-565
    • /
    • 2014
  • This paper investigates the design of a perfect point load actuator based on flat triangular piezoelectric patches. Applying a difference of electric potential between the electrodes of a triangular patch leads to point loads at the tips and distributed moments along the edges of the electrodes. The previously derived analytical expressions of these forces show that they depend on two factors: the width over height (b/l) ratio of the triangle, and the ratio of the in-plane piezoelectric properties ($e_{31}/e_{32}$) of the active layer of the piezoelectric patch. In this paper, it is shown that by a proper choice of b/l and of the piezoelectric properties, the moments can be cancelled, so that if one side of the triangle is clamped, a perfect point load actuation can be achieved. This requires $e_{31}/e_{32}$ to be negative, which imposes the use of interdigitated electrodes instead of continuous ones. The design of two transducers with interdigitated electrodes for perfect point load actuation on a clamped plate is verified with finite element calculations. The first design is based on a full piezoelectric ceramic patch and shows superior actuation performance than the second design based on a piezocomposite patch with a volume fraction of fibres of 86%. The results show that both designs lead to perfect point load actuation while the use of an isotropic PZT patch with continuous electrodes gives significantly different results.

HA Study on the Selection of Mobile Crane Model for Heavy Equipments Installation (중량물 설치 시 이동식 크레인 기종선정에 관한 연구)

  • Jeong, Jae-Bok;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.59-69
    • /
    • 2012
  • This study focuses on avoiding the failures from the wrong selections by experiences as simulation programs is not available, and suggests the methods which effectively select the alternatives when the selected model is not appropriate for the original plan. First, CC8800-1K of DEMAG has the longest boom whose length is 216 m at the maximum. The combination of the boom is feasible to second level except for MANITIWOC M 2250 (M-1200 RINGER) which is possible to third level. Second, the angle of boom is from 20 degrees to 82 degrees. Suitable angle to work is in the 55-78 degrees. The working load of crawler type and hydraulic one to be applied is 75-85% in the critical loads capacity. As increasing operating radius, crawler type is a favorable position over hydraulic one. Lastly, related problems were verified through examination by suggestions for the design of the selection methods for the case analysis. The major problems are stemming from the selection based on its experiences, unreasonable demand for the existing facility and repeated selections by the designer who accumulates his experiences via same or similar projects.

  • PDF