• Title/Summary/Keyword: Impulsive model

Search Result 193, Processing Time 0.022 seconds

Computational Fluid Dynamics of Cavitating Flow in Mixed Flow Pump with Closed Type Impeller

  • Kobayashi, Katsutoshi;Chiba, Yoshimasa
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.2
    • /
    • pp.113-121
    • /
    • 2010
  • LES(Large Eddy Simulation) with a cavitation model was performed to calculate an unsteady flow for a mixed flow pump with a closed type impeller. First, the comparison between the numerical and experimental results was done to evaluate a computational accuracy. Second, the torque acting on the blade was calculated by simulation to investigate how the cavitation caused the fluctuation of torque. The absolute pressure around the leading edge on the suction side of blade surface had positive impulsive peaks in both the numerical and experimental results. The simulation showed that those peaks were caused by the cavitaion which contracted and vanished around the leading edge. The absolute pressure was predicted by simulation with -10% error. The absolute pressure around the trailing edge on the suction side of blade surface had no impulsive peaks in both the numerical and experimental results, because the absolute pressure was 100 times higher than the saturated vapor pressure. The simulation results showed that the cavitation was generated around the throat, then contracted and finally vanished. The simulated pump had five throats and cavitation behaviors such as contraction and vanishing around five throats were different from each other. For instance, the cavitations around those five throats were not vanished at the same time. When the cavitation was contracted and finally vanished, the absolute pressure on the blade surface was increased. When the cavitation was contracted around the throat located on the pressure side of blade surface, the pressure became high on the pressure side of blade surface. It caused the 1.4 times higher impulsive peak in the torque than the averaged value. On the other hand, when the cavitation was contracted around the throat located on the suction side of blade surface, the pressure became high on the suction side of blade surface. It caused the 0.4 times lower impulsive peak in the torque than the averaged value. The cavitation around the throat caused the large fluctuation in torque acting on the blade.

DYNAMIC 3-DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR FRACTURE MECHANISM (충격하중(衝擊荷重)과 하악골(下顎骨) 골절발생(骨折發生) 기전(機轉)의 유한요소법적(有限要素法的) 연구(硏究))

  • Oh, Seung-Hwan;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.470-487
    • /
    • 1996
  • The purpose of this study was to investigate the dynamic response of the mandible to impact and provide insight into the fracture mechanism of the mandible, by 3-dimensional finite element method. The finite element model of the mandible was developed and calculated using NASTRAN/XL (MSC co. U.S.A.) and the linear dynamic transient analysis was performed according to the impulsive force direction, force type and impulse time to the mandible. At first, the load was applied on the mandibular symphysis, body, angle and subcondylar area in the horizontal mandibular plane and the computed stress-time histories at 14 locations of the mandible were obtained. Secondly, the impulsive force was directed to the symphyseal area with changing the force magnitude and impulse time, and calculated the node displacement at 8 locations of mandible. The conclusions from from this study were as follows. 1. The appearance of impulsive energy transmission was different to the direction of impulse to the mandible. 2. The impulsive stress and deformation were larger in lingual or medial side than buccal or lateral in the mandible. 3. The velocity, appearance of energy transmission and the fracture pattern in mandible were affected rather impulse time than force. 4. The horizontal impact to the one side of mandible did not have effect on the stress and displacement of contralateral mandible. From the above results, fracture pattern in symphysis can be showed as simple or comminuted, multiple or associated in body and angle and solitary in subcondyle area.

  • PDF

An Enhanced Affine Projection Sign Algorithm in Impulsive Noise Environment (충격성 잡음 환경에서 개선된 인접 투사 부호 알고리즘)

  • Lee, Eun Jong;Chung, Ik Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.420-426
    • /
    • 2014
  • In this paper, we propose a new affine projection sign algorithm (APSA) to improve the convergence speed of the conventional APSA which has been proposed to enable the affine projection algorithm (APA) to operate robustly in impulsive noise environment. The conventional APSA has two advantages; it operates robustly against impulsive noise and does not need calculation for the inverse matrix. The proposed algorithm also has the conventional algorithm's advantages and furthermore, better convergence speed than the conventional algorithm. In the conventional algorithm, each input signal is normalized by $l_2$-norm of all input signals, but the proposed algorithm uses input signals normalized by their corresponding $l_2$-norm. We carried out a performance comparison of the proposed algorithm with the conventional algorithm using a system identification model. It is shown that the proposed algorithm has the faster convergence speed than the conventional algorithm.

The Performance Analysis of DS/SSMA BPSK Correlation Receivers in Electric Power Line Channel (전력선 채널에서의 DS/SSMA BPSK 코릴레이션 수신기 성능에 관한 연구)

  • Kang, Byeong-Kwon;Cho, Chang-Gil;Cho, Kwan;Lee, Jae-Kyeong;Whang, Keum-Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.9
    • /
    • pp.972-981
    • /
    • 1992
  • In this paper, the performance of linear and hard-limiting correlation receivers for DS/SSMA BPSK power line communication system is analyzed. Strong impulsive noise of power line is modeled with Chan's noise model, and the performance of both receivers is analyzed in terms of parameters such as ratio of power spectrum density of impulsive noise to that background noise, ratio in impulsive noise width th that of data bit, and interarrival time of impulsive noise. And also multiple access capacity is evaluated with Gaussian approximation of multiple access interference. The results of this analysis reveal that the performance of linear correlation receiver is superior to that of hard-limiting correlation receiver when $N_1/N_b$ is small and is close to 1. But the BER and the multiple access capacity of hard-limiting correlation receiver becomes better in comparison with linear correlation receiver as $N_1/N_b$ increases.

  • PDF

A Simple Behavioral Paradigm to Measure Impulsive Behavior in an Animal Model of Attention Deficit Hyperactivity Disorder (ADHD) of the Spontaneously Hypertensive Rats

  • Kim, Pitna;Choi, In-Ha;Dela Pena, Ike Campomayor;Kim, Hee-Jin;Kwon, Kyung-Ja;Park, Jin-Hee;Han, Seol-Heui;Ryu, Jong-Hoon;Cheong, Jae-Hoon;Shin, Chan-Young
    • Biomolecules & Therapeutics
    • /
    • v.20 no.1
    • /
    • pp.125-131
    • /
    • 2012
  • Impulsiveness is an important component of many psychiatric disorders including Attention-deficit/hyperactivity disorder (ADHD). Although the neurobiological basis of ADHD is unresolved, behavioral tests in animal models have become indispensable tools for improving our understanding of this disorder. In the punishment/extinction paradigm, impulsivity is shown by subjects that persevere with responding despite punishment or unrewarded responses. Exploiting this principle, we developed a new behavioral test that would evaluate impulsivity in the most validated animal model of ADHD of the Spontaneously Hypertensive rat (SHR) as compared with the normotensive "control" strain, the Wistar Kyoto rat (WKY). In this paradigm we call the Electro-Foot Shock aversive water Drinking test (EFSDT), water-deprived rats should pass over an electrified quadrant of the EFSDT apparatus to drink water. We reasoned that impulsive animals show increased frequency to drink water even with the presentation of an aversive consequence (electro-shock). Through this assay, we showed that the SHR was more impulsive than the WKY as it demonstrated more "drinking attempts" and drinking frequency. Methylphenidate, the most widely used ADHD medication, significantly reduced drinking frequency of both SHR and WKY in the EFSDT. Thus, the present assay may be considered as another behavioral tool to measure impulsivity in animal disease models, especially in the context of ADHD.

Improved dynamic model of the impact hammer (개선된 충격해머의 동역학적 모델)

  • Lim, Byoung-Duk;Park, Jung-Hyun;Heo, Joon-Hyeok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.372.1-372
    • /
    • 2002
  • Although impact hammer is widely used as a convenient excitation tool in structural modal testing, little is known about the dynamic charateristics of its impulse mechanism. Transmission of the impulsive force to the structure depends on the dynamic properties of the impact hammer as well as the stiffness of the tip. An improved dynamic model of the impact hammer is proposed in this study with numerical simulations based on this model. (omitted)

  • PDF

Beat Maps of a Slightly Asymmetric Ring (미소 비대칭 링의 맥놀이 지도)

  • 박석균;박기영;서백수;김석현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1169-1176
    • /
    • 2002
  • Analytical model of beat response is derived on a slightly asymmetric ring and is veryfied by experiment. The asymmetric ring is a simplified model used to explain the beat property of a Korean bell. The asymmetric ring has mode pair having slight frequency difference in each radial mode. Each mode pair produces beat phenomenon by the interaction of the two close frequency components. Based on the analytical model, beat maps are first proposed and characteristics of beat on the circumference are detaily explained.

  • PDF

Analytical assessment of elevated tank natural period considering soil effects

  • Maedeh, Pouyan Abbasi;Ghanbari, Ali;Wu, Wei
    • Coupled systems mechanics
    • /
    • v.5 no.3
    • /
    • pp.223-234
    • /
    • 2016
  • The main purpose of current study is to find the soil effects on natural period of elevated tank. The coupled analytical method is used to assess in this study. The current study presented models which are capable to consider the soil dynamic stiffness changes and fluid- structure interaction effects on natural period of elevated tanks. The basic of mentioned models is extracted from elastic beam and lumped mass theory. The finite element is used to verify the results. It is observed that, external excitation can change the natural period of elevated tanks. Considering the increase of excitation frequency, the natural period will be decreased. The concluded values of natural period in case of soft and very soft soil are more affected from excitation frequency values. The high range of excitation frequency may reduce the natural period values. In addition it is observed that the excitation frequency has no significant effect on convective period compare with impulsive period.

Experimental Analysis about Influence Parameters at the Propagation of Large Arm’s Firing Noise (대구경 사격소음 전달 영향인자에 대한 실험적 분석)

  • Kim, Eung-Su
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.412-419
    • /
    • 2016
  • The firing noise produced at artillery test range or military training ground is impulsive burst noise which energy is generated within tens of milliseconds and distributed an isolated burst of sound energy separated to one by one noise. The long range propagation of this noise is affected by a caliber of gun, amount of propellant, distance between source and receiver, ground and meteorological condition. In this paper, main influence parameters have been described based on experimental analysis of measured data. It is considered that this analysis result can be used as useful materials for study of effective firing noise management and development of propagation model.

Numerical prediction of transient hydraulic loads acting on PWR steam generator tubes and supports during blowdown following a feedwater line break

  • Jo, Jong Chull;Jeong, Jae Jun;Yun, Byong Jo;Kim, Jongkap
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.322-336
    • /
    • 2021
  • This paper presents a numerical prediction of the transient hydraulic loads acting on the tubes and external supports of a pressurized water reactor (PWR) steam generator (SG) during blowdown following a sudden feedwater line break (FWLB). A simplified SG model was used to easily demonstrate the prediction. The blowdown discharge flow was treated as a flashing flow to realistically simulate the transient flow fields inside the SG and the connected broken feedwater pipe. The effects of the SG initial pressure or the broken feedwater pipe length on the intensities or magnitudes of transient hydraulic loads were investigated. Then predictions of the decompression pressure wave-induced impulsive pressure differential loads on SG tubes and the transient blowdown loads on SG external supports were demonstrated and the general aspects of transient responses of such transient hydraulic loads to the FWLB were discussed.