• 제목/요약/키워드: Impulse Response Sequence

검색결과 43건 처리시간 0.025초

PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구 (A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence)

  • 오휘명;최성수;이재조;김관호;황금찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권1호
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

상호상관법에 의한 건축음향측정에 관한 연구 (Study on the Measurements of Architectural Acoustie by Cross-Correlation Methods)

  • 박병전;신영무
    • 한국음향학회지
    • /
    • 제9권2호
    • /
    • pp.42-52
    • /
    • 1990
  • 음향전파 측정에 상호상관법(직접법과 M계열 변조상관법)을 이용하므로서 임펄스 입력에 의한 경우와 같은 결과를 얻을 수 있다는 것과, 또 상호상관법의 특징인 외란노이즈의 영향을 줄일 수 있었던 것 등을 건축음향분야에서 측정계를 대상으로 하여 이론적으로 정리하였다. 또 이들 계측법을 응용하여 흡음재료의 사입사 흡음특성의 측정, 실의 단독 단음응답 및 잔향감쇄 과정의 측정, 음압레벨 분포, 차음성능 등을 측정하고 여러 건축음향측정에서 이들 방법이 유효하다는 것을 실험적으로 확인하였다.

  • PDF

페이딩 채널의 임펄스 응답 측정을 위한 이진 시퀀스와 수신기 (A Binary Sequence and Receiver for measurement of Fading Channel Impulse Response)

  • 김동석;한영열
    • 전자공학회논문지A
    • /
    • 제32A권10호
    • /
    • pp.1-7
    • /
    • 1995
  • In this paper, the properties of autocorrelation function of binary sequences are investigated. From these properties, the binary sequences which can be used for measurement of impulse response on fading channel are found by computer search. A receiver which can measure impulse response by use of these binary sequences is devised. This devised measurement system produces zero values of autocorrelation function for the all delays except zero sight.

  • PDF

Identification of 2D Impulse Response by use of M-array with Application to 2D M-transform

  • Liu, Min;Kashiwagi, Hiroshi;Kobatake, Hidefumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.234-237
    • /
    • 1999
  • In this paper, a new method for identification of two-dimensional(2D) impulse response is presented. As is well known, identification of 2D impulse response is an important and necessary theme for image processing or signal processing. Here, the authors extend M-transform which has been proposed by some of the authors to 2D case where an image is used instead of signal, and M-array is used instead of M-sequence. Firstly, we show that 2D impulse response can be obtained by use of M-array. Next 2D M-transform is defined where any 2D image can be considered to be the output of 2D filter whose input is 2D M-array. Simulation results show the effectiveness of identification of 2D impulse response by either using M-array or by 2D M-transform.

  • PDF

한국 표준으로 제안된 GCR에 의한 임펄스 응답특성에 관한 연구 (A study on the impulse response characteristics by using the GCR proposed for korean standard)

  • 권병헌;주광철
    • 한국통신학회논문지
    • /
    • 제21권4호
    • /
    • pp.1027-1037
    • /
    • 1996
  • This paper presents an impulse response of the multi-path channel using KS-GCR(Korean Standard Ghost Cancel Reference) signal. Using the property of the KS-GCRsignal, we can get the impulse response of the multi-path channel from circular cross correlation of the received DS-GCR signal and the orginal KS-GCR ternary sequence. Therefore impulse response of the multi-path channel can be used to design the the ghost cancellation filter if it is designed to have inverse characteristics of multi-path channel. This paper shows that the ghost occurred from the multi-path channel can be cancelled by using the impulse response and preceding ghost cancellation algorithm.

  • PDF

A Study on Identification of Nonminimum Phase Stable System from Partial Impulse Response Sequences

  • Lee, Won-Cheol;Bae, Myung-Jin;Im, Sung-Bin
    • The Journal of the Acoustical Society of Korea
    • /
    • 제15권1E호
    • /
    • pp.45-58
    • /
    • 1996
  • This paper addresses the problem of identifying the class of all stable system transfer functions that interpolate the given partial impulse response sequence. In this context, classical Pade approximations that are also stable, are shown to be a special case of this general formulation. The theory developed in this connection is utilized to obtain a new criterion for determining the model order and system parameters for rational systems, and, further, to generate nonminimum phase optimal stable rational approximatinos of nonrational systems from its impulse response sequence.

  • PDF

2차원 디지털 필터의 반복실현에 관한 연구 (A Study on the Iterative Implementation of 2-D Digital Filter)

  • 장태용;이윤현
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1984년도 추계학술발표회논문집
    • /
    • pp.82-87
    • /
    • 1984
  • A 2-D digital filter with rational frequency response can be expanded into an infinite sequence of filterins operations. Each filtering operation can be implemented by convolution with a Low-order 20D finite-extent impulse response. If a convergence constraint is satisfied, the sequence of estimates will approach the desired output signal. In practice, as the number of iterations is finite, the frequency response implemented by iterative computations is an approximation to the desired rational frequency response.

  • PDF

임펄스응답을 이용한 실내음향 측정 시스템 (Room Acoustic Measurement System Using Impulse Response)

    • 한국음향학회지
    • /
    • 제18권5호
    • /
    • pp.63-67
    • /
    • 1999
  • 최근 들어 실내음향 특성의 측정과 평가를 위해 백색잡음을 이용한 잔향시간 측정법 대신에 임펄스응답을 이용한 측정법이 널리 이용되고 있다. 이 방법은 재현성이 우수하고 다양한 실내음향 특성치들을 한꺼번에 산출할 수 있어 전통적인 잔향시간 측정법에 비해 여러 가지 장점을 가지고 있다. 본 연구에서는 MLS(Maximum Length Sequence) 신호를 이용하여 실내에서의 임펄스 응답을 측정하고 이를 후처리(post-processing) 하여 잔향시간(EDT, RT), 명료도 지수(C50, C80, D, U50, U80, AI), 음의 크기 지수(G) 등, 주로 실의 음성음향 성능을 측정하는 시스템을 구축하였다. 본 연구에서는 측정시스템과 후처리 프로그램의 구성, 몇몇 실내공간에 대한 시험 측정의 결과 및 고찰 등에 대해 소개하고자 한다.

  • PDF

OFDM 기반 WLAN 수신기에서 효율적인 채널추정 기법에 관한 연구 (A Study on the Effective Channel Estimation Method in OFDM Based WLAN)

  • 전형구;최원철;이현;오현서
    • 한국ITS학회 논문지
    • /
    • 제4권1호
    • /
    • pp.57-62
    • /
    • 2005
  • 본 논문에서는 OFDM 시스템에서 임펄스 신호를 이용한 채널 추정방법을 제안한다. 채널 응답을 추정하기 위해 주파수 영역에서 새로운 프리엠블을 사용하여 시간영역에서 16샘플 간격으로 4개의 구간으로 나누고, 각 구간에서 임펄스 응답이 나오도록 한다. 이 임펄스 신호들은 한 OFDM 심볼동안에 전송한다. 수신단에서, 각 구간별 임펄스 신호를 더하여 평균을 취한다. 평균된 임펄스 응답에서 최대지연 이후 데이터는 잡음이기 때문에 zero padding을 하여 제거하고 FFT를 수행하여 채널 추정 응답을 찾아낸다. 제안된 채널 추정방법을 이용한 WLAN 시스템의 BER성능은 IEEE802.11a에서 사용하는 긴 훈련신호(long preamble)를 이용한 기존의 채널 추정 방법에 비해 약 3dB 성능 향상을 보인다.

  • PDF

새로운 채널 추정방법에 관한 연구 (On new channel estimation method)

  • 송석일;한영열
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2240-2247
    • /
    • 1998
  • 본 논문은 이진 사운딩시퀀스를 이용하여 채널 임펄스응답을 측정하는 새로운 방법에 대하여 기술하였다. 이 새로운 방법은 한개의 상관기를 이용하는 대신에 세 개의 상관기를 이용하나 이상적인 채널 임펄스응답을 얻을 수 있다. 본 세안 방법에서 이용되는 사운딩 시퀀스의 부류는, GSM에 기반을 둔 디지틀 셀루리 이동전화 시스템에서 사용하는 채널 임펄스응답측정 이진부호로서 0 지연과 중간 지연을 제외한 모든 지연에서 자기상관함수 값이 영의 값을 갖는 채널응답측정을 위한 트레이닝 시퀀스이다. 또한 본 논문에서는 0 지연과 중간 지연을 제왼한 모든 지연에서 자기상관함수 값이 영이 되는 이진부호를 탐색하는 효과적인 방법을 제시한다.

  • PDF