• Title/Summary/Keyword: Impulse Reduction

Search Result 176, Processing Time 0.024 seconds

Non-Impulse Noise Reduction of Binary Image based on Morphological Arithmetic (형태학적 연산에 기반한 이진영상의 비임펄스 잡음제거)

  • 김재석;정성옥
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.6
    • /
    • pp.909-914
    • /
    • 2002
  • In this thesis, noise reduction of image with impulse noise in circle image removed noise to harness existing median filter for noise reduction from image data of damage by noise when impulse noise is high or noise reduction is low, but it is not made up of noise reduction to harness existing median filter in case of existence of non-impulse noise. Therefore noise reduction of image with non-impulse noise had to remove noise by morphological arithmetic in this thesis's proposition. In contrast to median filtering, result of edge detection is more efficient after remove non-impulse noise by method of thesis's proposition and it compare and demonstrate through this experimentation.

Properties of a Generalized Impulse Response Gramian with Application to Model Reduction

  • Choo, Younseok;Choi, Jaeho
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.4
    • /
    • pp.516-522
    • /
    • 2004
  • In this paper we investigate the properties of a generalized impulse response Gramian. The recursive relationship satisfied by the family of Gramians is established. It is shown that the generalized impulse response Gramian contains information on the characteristic polynomial of a linear time-invariant continuous system. The results are applied to model reduction problem.

An Empirical Study on the Influencing Factors of Chinese Consumers' Impulse Buying Behavior During Online Shopping Festivals after COVID 19 - focused on the Meditating Role of Perceived Value (COVID-19 이후 온라인쇼핑 축제기간 중국 소비자의 충동구매행태 영향요인에 관한 실증연구-인식된 가치의 매개 역할을 중심으로)

  • Xu Kai;Woohyoung Kim;Yongseok Cho
    • Korea Trade Review
    • /
    • v.46 no.6
    • /
    • pp.163-190
    • /
    • 2021
  • The paper studies the impulse buying behavior of Chinese consumers during the online shopping festivals of the specific situations and their influencing factors with empirical analysis. We carried out an empirical analysis on 302 Chinese consumers with shopping experience in the online shopping festival. The study result shows that (1) marketing stimulation, preferential promotion and features of consumers have a significant positive influence on the impulse buying behavior; while the freight reduction has no significant influence on impulse buying behavior; (2) the perceived value has a significant positive influence on the Chinese consumers to have impulse buying behavior; (3) perceived value works as an in the relationship between the marketing stimulation, preferential promotion and features of consumers and the impulse buying behavior, but it has no meditating role between the freight reduction and the impulse buying behavior.

A New Consideration for Discrete-System Reduction via Impulse Response Gramian

  • Younseok Choo;Park, Jaeho
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.3
    • /
    • pp.384-389
    • /
    • 2004
  • Recently a method of model reduction for discrete systems has been proposed in the literature based on a new impulse response Gramian. In this method, the system matrix$A_r$ of a reduced model is computed by approximating the reduced-order impulse response Gramian. The remaining matrices $b_r$ and $c_r$ are obtained so that various initial Markov parameters and time-moments of the original system are preserved in the reduced model. In this paper a different approach is presented based on the recursive relationship among the impulse response Gramians.

An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구)

  • Song, Hwa-Young;Ju, Kyung-Min;Lee, Dong-Hoon;Kang, Rae-Goog;Jung, Nak-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

Progressive Filter for Impulse Noise Reduction (임펄스 잡음제거를 위한 프로그레시브 필터)

  • Kim, Young-Ro;Dong, Sung-Soo
    • 전자공학회논문지 IE
    • /
    • v.49 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • In this paper, we propose a progressive filter for impulse noise reduction. The proposed method uses non-linear filter and linear filter progressively. Non-linear filter reduces abrupt noise pattern. Also, linear filter adjusts filtering direction according to an edge in the image which is filtered by non-linear filter. Thus, our proposed method not only preserves edge, but also reduces noise in uniform region. Experimental results show that our proposed method has better quality than those by existing non-linear and linear progressive filtering methods.

A Study on Calcium Ion Reduction in Power Plant Water using High Voltage Impulse (고전압 임펄스를 활용한 발전용수 칼슘농도 저감에 관한 연구)

  • Kim, TaeHui;Chang, In-Soung;Jung, Jae-Hwan;Hong, Woong ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.545-550
    • /
    • 2017
  • As an alternate technique for water softening, high voltage impulse (HVI) is introduced and verified if it can control the $CaCO_3$ scale formation in industrial water treatment. After HVI was applied to the artificial hard water containing $100{\pm}5mg/L$ $Ca^{2+}$ for 4 hours, the $Ca^{2+}$ concentration and the electrical conductivity were measured. The concentration of $Ca^{2+}$ was reduced from 94.5 to 86.3 mg/L (8.7% reduction) after 4 hour contact of HVI under 5 kV condition. The $Ca^{2+}$ was decreased from 92 to 77.7 mg/L (15.6% reduction) at 8kV and from 90.1 to 75.4 mg/L (16.3% reduction) at 12 kV condition. Both of the contact time and the applied voltage were important parameters affecting the calcium ion reduction. With these results, it was verified that HVI technique could be potential candidate for control of $CaCO_3$ scale formation.

An Experimental Study on the Control of Duration time of Impulse Noise from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 지속시간 제어에 관한 실험적 연구)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.258-261
    • /
    • 2006
  • This study introduces the control of duration time of impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level over 150 dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study, the reactive type silencer has been utilized. And also electrical interrupting test was experimented. From the experimental results, the reactive type silencer has been shown to have the noise reduction of about 13 dB(A). It has been found that the electrical interception performance of the COS fuse was related to the control of the duration time of impulse noise.

  • PDF

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.