• Title/Summary/Keyword: Impulse Current

Search Result 369, Processing Time 0.025 seconds

Design Criteria of the Median Barrier Considering Impulse Measurement (충격량을 고려한 중앙분리대 설계기준에 관한 연구)

  • Park, Je-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.2
    • /
    • pp.167-176
    • /
    • 2008
  • Although a rate of car accident death is on the decrease, internal rate of median encroachment accident is still high. In order to reduce the median encroachment accident, government use median barriers but there are no exact criteria of them. Particularly, current impulse measurement method has adopted the uniformly operating speed and encroachment angle. At reality, however, there are various conditions depends on driver's characters. In that reason, this study calculates reasonable impulse quantity through encroachment angle and operating speed. It will be necessary to prevent overuse treasury and car accidents.

Transient Ground Impedances According to Shapes of Grounding Electrodes (접지전극의 형상에 따른 과도접지임피던스)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Jeong, Dong-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • This paper presents the transient behaviors of grounding system impedance against lightning impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current were investigated. The transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system Also, the deeply-driven ground rod was effective to reduce the transient ground impedance in time domain of miceroseconds.

Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages (임펄스전압에 대한 누전차단기의 부동작 특성)

  • Lee, Bok-Hee;Chang, Sug-Hun;Lee, Seung-Chil
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

Distributions of the Magnetic Flux Density Near Down-Conductors Due to Various Impulse Currents (임펄스전류에 의한 인하도선 주위에서 자속밀도의 분포)

  • 이복희;장근철;이수봉;강성만;이승칠
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2004
  • This paper deals with the behaviors of magnetic flux density near down-conductors by lightning currents. The background on the principle of magnetic flux density measurements using the RL self-integrating magnetic field sensor was described. The magnetic flux density measuring device consisting of RL self-integrating magnetic field sensor and differential amplifier was designed and fabricated. The frequency bandwidth of the magnetic flux density measuring system ranges from 200 Hz to 300 KHz and the response sensitivity was 0.126 $\mu$T/㎷ The distributions of the magnetic flux density near down-conductors due to impulse currents with various rise times were analyzed as a parameter of the bonding conditions and materials of conductor and wiring conduits. The magnetic flux density due to impulse currents was inversely proportional to the distance between the down-conductor and measuring point. The amplitude of the magnetic flux density for PVC Pipe with down-conductor was 72 $\mu$T/㎷ at the distance of 1m and was higher than for steel conduits and coaxial cable. Finally the magnetic flux density is increased with increasing the di/dt it and oscillation frequency of lightning currents in this experimental ranges.

A Design of Current-Mode Analog FIR Filter for Wireless Home Network (주파수가변형 무선PAN단말을 위한 전류모드 아날로그 FIR 필터의 설계)

  • Kim, Seong-Kweon;Kim, Kwang-Ho;Cho, Ju-Phil;Cha, Jae-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.35-40
    • /
    • 2006
  • In this paper, a current-mode analog variable finite-impulse-response (FIR) filter with variable tap coefficient circuits is proposed for frequency selective wireless personal area network(WPAN) system or terminals. From the circuit simulation the operation of the 7-tap FIR filter is confirmed. The 0.0625-step tap coefficient circuit is designed and fabricated with $0.8[{\mu}m]$ CMOS technology. The proposed FIR filter has a variable length of taps and variable coefficients, so it has a potential for being used to frequency selective WPAN system or frequency selective wireless communication terminals.

Predischarge Phenomena in Nonuniform Fields Caused by Lightning Impulse Voltages in SF(sub)6-$N_2$Mixtures (SF(sub)6-$N_2$혼합가스중에 뇌임펄스전압에 의해 형성된 불평등전장에서의 전구방전현상)

  • 이복희;이경옥;백승권
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.288-295
    • /
    • 2001
  • Predischarges in nonuniform electric field stressed by lightning impulse voltagesin SF(sub)6-$N_2$mixtures are initiated by streamer coronas. Due to field ehnancement at a protrusion point of electrodes new ionization processes occur and a precursor, which leads to a first leader, is created. The leader proceeds step by step to the opposite electrode and the final jump bridges the test gap. It was found that the predischarge is propagated with a leader mechanism of stepwise expansion from the predischarge current waveforms measured by a shunt. The predischarge current is closely related to the amplitude and polarity of applied voltages, the gas pressure and the gap geometry. The time intervals between step leaders for the positive and negative polarities were inversely proportional to V.P$^2$. When the gas pressure increases in the positive polarity, statistical time lag to statistical time lag to streamer corona inception increase slightly, but the formative time lag to flashover is significantly decreased.

  • PDF

Exports of SMEs against Risk? Theory and Evidence from Foreign Exchange Risk Insurance Schemes in Korea

  • Lee, Seo-Young
    • Journal of Korea Trade
    • /
    • v.23 no.5
    • /
    • pp.87-101
    • /
    • 2019
  • Purpose - This paper examines the effectiveness of the foreign exchange risk insurance system in the promotion of SME exports in Korea. The purpose of this study is to analyze the short-term and long-term responses of SME exports to foreign exchange risk insurance support policies. Based on these empirical studies, we would like to present some operational improvements to the operation of the foreign exchange risk insurance system. Design/methodology - In order to analyze the effect of exchange risk insurance on the exports of SMEs, a VAR model consisting of foreign exchange risk insurance underwriting values, export relative price, and domestic demand pressure, including export volume, was established. The study began with tests of the stationarity of time series data. The unit root tests showed that all concerned variables were non-stationary. Accordingly, the results of the cointegration test showed that the tested variables are not cointegrated. Finally, an impulse response function and variance decomposition analysis were conducted to analyze the impulse of foreign exchange risk insurance on exports of SMEs. Findings - As a result of estimating the VAR (1) model, foreign exchange risk insurance was found to be significant at a 1% significance level for SME' export promotion. In the impulse response analysis, SMEs' export response to the impulse of foreign exchange risk insurance showed that exports gradually increased until the third quarter, and then slowed down. However, the impulse did not disappear, and appeared continuously. Originality/value - This study analyzed the effect of foreign exchange insurance on exports of SMEs by applying the VAR model. In particular, this study is the first to analyze the short-term and long-term effects of foreign exchange risk insurance on exports of SMEs. The empirical evidence in the current study have a policy implication for the policy authority to support and promote the foreign exchange risk insurance in the effect of exchange rate volatility on Korea' export SMEs.

Breakdown Characteristics of Soils Caused by Impulse Currents (임펄스전류에 의한 토양의 절연파괴특성)

  • Lee, Bok-Hee;Lee, Kang-Soo;Kim, Hoe-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.103-109
    • /
    • 2010
  • In this paper, breakdown characteristics of soil in a coaxial cylindrical electrode system stressed by impulse currents were experimentally investigated. The breakdown voltage and current waveforms for 4 types of soils were measured, and the threshold electric field intensity, the time-lag to breakdown and the voltage-current (V-I) curves were analyzed and discussed. As a result, the breakdown voltage and current waveforms are strongly dependent on the grain size of soil, and the voltage and current waveforms for gravel and sand differ from those for silt and loess. The threshold electric field intensity Ec is increased in the order of gravel, sand, loess and silt. The V-I curves for all test samples show a 'cross-closed loop' of ${\infty}$-shape. Also, the time-lag to breakdown for gravel and sand are longer than those for silt and loess. It is expected that the results presented in this paper will provide useful information on the design of improving transient performance of a grounding electrode system subjected to lightning current considering the soil ionization.

Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages (직류+60[Hz] 교류 중첩전압에 대한 ZnO 피뢰기 소자의 전기적 특성)

  • Lee, Bok-Hee;Yang, Soon-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.41-47
    • /
    • 2012
  • This paper deals with the electrical characteristics related to power loss, equivalent resistance, and leakage currents flowing through new and deteriorated zinc oxide(ZnO) arrester elements subjected to the mixed DC and 60[Hz] AC voltages. The test specimens were deteriorated by 8/20[${\mu}s$] impulse current of 2.5[kA]. The leakage current-applied voltage($I-V$) characteristic curves of ZnO surge arrester elements were measured as a parameter of the ratio of the peak of 60[Hz] AC voltage to the peak of total voltage. As a consequence of test results, in case of the same applied voltage, the leakage currents flowing through the deteriorated ZnO arrester elements were higher than those flowing through the new ZnO surge arrester elements. The cross-over phenomenon in $I-V$ curves of ZnO surge arrester elements measured as a parameter of the mixed ratio of DC and AC voltages was observed at the low current domain. The effect of DC voltage on the leakage current flowing through ZnO surge arrester elements is pronounced at the same magnitude of test voltages. In addition, the larger the applied number of 8/20[${\mu}s$] impulse current of 2.5[kA] is, the greater the power loss is, in particular, the more severe the power loss increases at higher applied voltages.

Changes in Electrical Properties of ZnO Surge Arresters According to Surrounding Conditions (외부 환경조건에 따른 ZnO 피뢰기의 전기적 특성의 변화)

  • Lee, Seung-Ju;Lee, Su-Bong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.62-68
    • /
    • 2008
  • This paper describes the electrical characteristics of ZnO surge arresters associated with the variation of surrounding conditions. To investigate the deterioration behaviors of ZnO surge arresters due to lightning surges, 8/20[${\mu}s$], 2.5[kA] impulse currents were injected to the ZnO surge arrester under test. The leakage currents of ZnO surge arrester subject to power frequency AC voltage were measured in different surrounding temperature and wet conditions. As a result, it was found that the leakage current is increased and its asymmetry is pronounced as the number of injection of the impulse current and the ambient temperature increase. Also, in the wet test the outside leakage current flowing through the housing surface of the ZnO surge arrester is much larger than the intrinsic leakage current of ZnO surge arrester element. The results obtained in this work can be a lied as factors of improving the reliability and performance of monitoring system for surge arresters.