• Title/Summary/Keyword: Impulse Current

Search Result 369, Processing Time 0.027 seconds

A CMOS IR-UWB RFIC for Location Based Systems (위치 기반 시스템을 위한 CMOS IR-UWB RFIC)

  • Lee, Jung Moo;Park, Myung Chul;Eo, Yun Seong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.67-73
    • /
    • 2015
  • This paper presents a fully integrated 3 - 5 GHz IR-UWB(impulse radio ultra-wide band) RFIC for Location based system. The receiver architecture adopts the energy detection method and for high speed sampling, the equivalent time sampling technique using the integrated DLL(delay locked loop) and 4 bit ADC. The digitally synthesized UWB impulse generator with low power consumption is also designed. The designed IR-UWB RFIC is implemented on $0.18{\mu}m$ CMOS technology. The receiver's sensitivity is -85.7 dBm and the current consumption of receiver and transmitter is 32 mA and 25.5 mA respectively at 1.8 V supply.

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages (임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상)

  • Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

Transient Grounding Impedance Behaviors of Deeply-driven Ground Rods According to the Injection Point of Impulse Currents (임펄스전류의 인가위치에 따른 심매실 봉상 접지전극의 과도접지임피던스 특선)

  • Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jeon, Byung-Wook;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.62-68
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of deeply-driven ground rods associated with the injection point of impulse currents. The transient grounding impedance strongly depends on the length of deeply-driven ground rod and the rise time and injection point of impulse currents, and the intrinsic inductance of ground rod has a significant affect on the transient grounding impedance of grounding system in fast rise time ranges. The reduction of inductance is decisive to improve the impulse impedance behaviors of deeply-driven ground rods. It is effective that grounding conductor is connected to the top of the ground rod as short as possible.

Transient Response characteristics Associated with the Common Connection Points in Grounding Systems for Electric Power Utilitires (전력설비용 접지시스템에 공결점에 따른 과도응답특성)

  • 이복희;이승칠;엄주홍;심판섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.101-108
    • /
    • 1999
  • Ths paper describes the transient response characteristics of the grounding systems for electric power facilities against impluse currents. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations treasuring and analyzing potential rises induced at the cormron cormection trint and other grounding conductors were conducted. The lightning impulse current was awliErl so as to simulate the on-set of arrester due to lightning surges. Measured results of impulse response characteristics from the present experinrrits are as follows;

  • PDF

Analysis and Countermeasures for False-Tripping of Earth Leakage Breaker Due to Lightning Surge (누전차단기의 뇌써지 동작특성 분석 및 오동작 대책)

  • Lee, Jae-Bok;Myeong, Seong-Ho;Jo, Yeon-Gyu;Jang, Seok-Hun;Kim, Jeom-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.479-484
    • /
    • 2002
  • Recently it is reported that many a malfunction of ELB which is represented by non-operated type ELB for an impulse wave, is caused by lightning impulse and transient ground potential rise due to nearby lightning strokes. In order to examine the cause of malfunction, 5 samples were investigated experimentally in this study. As each ELB has a different leakage current detecting circuit and wiring method, various characteristics were measured. As a result, all of them brought about malfunctions under the lightning impulse voltage less than 7 kV and the surge current less than 3 kA. Also the different aspects were measured with a polarity of injected surge and a position of MOV to protect the inner circuit of ELB. The Position and effects of protecting devices were suggested as a remedy.

Prevalence of Peripheral Vestibular Impairment in Adults with Human Immunodeficiency Virus

  • Millar, Alison;Joubert, Karin;Naude, Alida
    • Korean Journal of Audiology
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Background and Objectives: Globally, the human immunodeficiency virus (HIV) is responsible for one of the most serious pandemics to date. The vulnerability of the vestibular system in individuals with HIV has been confirmed, and central vestibular impairments have been frequently reported. However, there are disagreements on the impact of HIV on peripheral vestibular function. Thus, the current study aimed to determine the prevalence of peripheral vestibular impairment, specifically related to the semi-circular canals (SCCs), in HIV-positive individuals receiving antiretroviral (ARV) treatment. Subjects and Methods: A total of 92 adults between the ages of 18 and 50 years (divided into two groups) participated in the study. The first group comprised HIV-positive individuals receiving ARV treatment (n1=60), and the second group comprised HIV-negative participants (n2=32). The video head impulse test was used to conduct the head impulse paradigm (HIMP). Results: Bilateral normal HIMP results were obtained in 95% of the HIV-positive participants and all HIV-negative participants. The gain of the left posterior SCCs was significantly lower in the HIV-positive group, while the gains of all other canals between the two groups were comparable. Conclusions: The prevalence of peripheral vestibular impairment in the HIV-positive group was not significantly different from that of the HIV-negative group. The reduced prevalence in the current study may be attributed to participant characteristics, the test battery employed, and the central compensation of the vestibular dysfunctions at the later stages of infection.

Prevalence of Peripheral Vestibular Impairment in Adults with Human Immunodeficiency Virus

  • Millar, Alison;Joubert, Karin;Naude, Alida
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Background and Objectives: Globally, the human immunodeficiency virus (HIV) is responsible for one of the most serious pandemics to date. The vulnerability of the vestibular system in individuals with HIV has been confirmed, and central vestibular impairments have been frequently reported. However, there are disagreements on the impact of HIV on peripheral vestibular function. Thus, the current study aimed to determine the prevalence of peripheral vestibular impairment, specifically related to the semi-circular canals (SCCs), in HIV-positive individuals receiving antiretroviral (ARV) treatment. Subjects and Methods: A total of 92 adults between the ages of 18 and 50 years (divided into two groups) participated in the study. The first group comprised HIV-positive individuals receiving ARV treatment (n1=60), and the second group comprised HIV-negative participants (n2=32). The video head impulse test was used to conduct the head impulse paradigm (HIMP). Results: Bilateral normal HIMP results were obtained in 95% of the HIV-positive participants and all HIV-negative participants. The gain of the left posterior SCCs was significantly lower in the HIV-positive group, while the gains of all other canals between the two groups were comparable. Conclusions: The prevalence of peripheral vestibular impairment in the HIV-positive group was not significantly different from that of the HIV-negative group. The reduced prevalence in the current study may be attributed to participant characteristics, the test battery employed, and the central compensation of the vestibular dysfunctions at the later stages of infection.

Robust FIR filter for Linear Discrete-time System

  • Quan, Zhong-Hua;Han, Soo-Hee;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2548-2551
    • /
    • 2005
  • In this paper, a robust receding horizon finite impulse response(FIR) filter is proposed for a class of linear discrete time systems with uncertainty satisfying an integral quadratic constraint. The robust state estimation problem involves constructing the set of all possible states at the current time consistent with given system input, output measurements and the integral quadratic constraint.

  • PDF