• Title/Summary/Keyword: Improvement efficiency

Search Result 5,557, Processing Time 0.036 seconds

Numerical Optimization for Performance Improvement of a Tunnel Ventilation Jet fan (터널 환기용 제트홴의 성능 향상을 위한 수치최적화)

  • Kim, Joon-Hyung;Kim, Jin-Hyuk;Kim, Kwang-Yong;Yoon, Joon-Yong;Choi, Young-Seok;Yang, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.63-68
    • /
    • 2011
  • This paper presents an optimization procedure for performance improvement of a tunnel ventilation jet fan. Optimization techniques based on response surface approximation (RSA) are employed to improve the aerodynamic performance of a tunnel ventilation jet fan. For numerical analysis, three-dimensional Renolds- averaged Navier-Stokes (RANS) equations with shear stress transport turbulence model are discretized by using finite volume approximations and solved on hexahedral grids to evaluate the total efficiency at the operating condition as the objective function. Four geometric variables defining the meridional length and the thickness profile at the hub and shroud in the jet fan rotor are selected as design variables for the numerical optimization. The results of the numerical optimization show that the total efficiency of the optimized model is significantly improved in comparison with the base model.

Efficiency Improvement of Switched Reluctance Generator According to Current Shape in the High Speed Region (고속영역에서 전류형상에 따른 스위치드 릴럭턴스 발전기의 효율 개선)

  • Ahn, Jin-Woo;An, Young-Joo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.68-74
    • /
    • 2015
  • This paper describes about the efficiency improvement of switched reluctance generator (SRG) over the rated speed region. Since the current shape has a great influence on the loss of the machine, so the system efficiency can be improved by optimizing the current shape. In case the wide speed range application such as wind power and medium size hydraulic power generation, a method of switching angle control is suggested to obtain the wanted current shapes. In order to verify the method, the experimental platform is set up. The feasibility of the theory is verified by simulation and experimental results.

A Study on Effect Analysis of Integrated Demand Management According to Energy System Management Model (Energy System Management 모형을 통한 통합 수요관리 효과분석에 관한 연구)

  • Kim, Yong-Ha;Jo, Hyeon-Mi;Kim, Young-Gil;Park, Hwa-Yong;Kim, Hyeong-Jung;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1339-1346
    • /
    • 2011
  • This paper is developed to demand management scenario of energy consumption efficiency improvement, electricity generation efficiency improvement, network efficiency improvement, change of distribution ratio, movement of energy source, change of heating system, put of CHP to quantitatively assess to impact on energy use of demand management at the national level. This scenario can be applied Energy System Management model was developed based on Energy Balance Flow. In addition, effect analysis through built demand management scenario was quantitatively evaluated integrated demand management effectiveness of energy cost saving, CO2 emission reduction and energy savings of national level by calculating to primary energy source usage change in terms of integration demand management effect more often than not a single energy source separated electricity, heat and gas.

Evaluation of Efficiency and Conformity of DMAIC-Based Battery Production System Challenge Solving Methodology: A Study on the Applicability for Improvement ("DMAIC 기반 배터리 생산시스템 과제해결방법론"의 효율성 및 적합성 평가: 개선을 위한 적용 가능성 연구)

  • Shin Chul Park;Joo Yeoun Lee;Myoung Sug Chung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.20 no.spc1
    • /
    • pp.30-44
    • /
    • 2024
  • The DMAIC methodology, which is most familiar to battery production system developers, is partially inadequate in its conformity to utilize battery production system tasks, so it is necessary to improve the function and structure of the methodology, but many battery production system developers use the DMAIC method based on experience, causing side effects such as confusion, delay in tasks, and insufficient performance during tasks. Accordingly, we intend to conduct an empirical study to improve the "efficiency improvement and conformity evaluation method" so that the DMAIC methodology can be used more reasonably and easily. Using the three-stage research model, we derive components that affect conformity through literature and questionnaire surveys in the first stage, use relational characteristics between components in the second stage to confirm the effect on conformity, and use the relational characteristics in the third stage to confirm the possibility of improving efficiency by applying them to the DMAIC methodology in actual cases. Finally, the "Conformity Assessment Index (CAI) equation" based on relational characteristics is established to enable effective conformity evaluation and continuous improvement.

Smoothed Particle Hydro-dynamic Analysis of Improvement in Sludge Conveyance Efficiency of Screw Decanter Centrifuge (입자 완화 유체 동역학 해석 기법을 이용한 스크류 디켄터형 원심분리기의 슬러지 이송 효율 향상 분석)

  • Park, Dae Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.285-291
    • /
    • 2015
  • A centrifuge works on the principle that particles with different densities will separate at a rate proportional to the centrifugal force during high-speed rotation. Dense particles are quickly precipitated, and particles with relatively smaller densities are precipitated more slowly. A decanter-type centrifuge is used to remove, concentrate, and dehydrate sludge in a water treatment process. This is a core technology for measuring the sludge conveyance efficiency improvement. In this study, a smoothed particle hydro-dynamic analysis was performed for a decanter centrifuge used to convey sludge to evaluate the efficiency improvement. This analysis was applied to both the original centrifugal model and the design change model, which was a ball-plate rail model, to evaluate the sludge transfer efficiency.

A Design and Implementation of modified ZigBee using the Directed-Messaging for Energy Efficiency Improvement (에너지 효율성 향상을 위하여 방향성 메시징을 사용하는 수정된 지그비의 설계 및 구현)

  • Khil, A-Ra
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.10
    • /
    • pp.99-105
    • /
    • 2012
  • ZigBee is the low power, low cost and low data rate wireless personal area network(LR-WPAN) standard. The Directed-Messaging is the protocol which improves the energy efficiency through reducing the redundant message transmission by transmitting messages with directional information toward the specified sub-network area in wireless sensor network using broadcasting. In this paper, we design and implement the experimental grid sensor network using ZigBee modified by the Directed-Messaging for the energy efficiency improvement. The experimental sensor network in this paper is configured with Nano24 supporting the ADV message and the routing management module modified to use the directional information. The energy efficiency improvement of the experimental sensor-network by evaluating the experimental results according to transmitting ADV message.

Apply a Model of CQI to the Hospital

  • Tsay W.D;Chen C.S;Lai M.C
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.673-679
    • /
    • 1998
  • The paper aims to apply a model of continuous quality improvement (CQI) to Taiwan provincial Pin Ton hospital. Tools of quality control were used both total quality management (TQM) and quality control circle (QCC) in order to approach the objective of ${\ulcorner}$higher quality, higher efficiency, lower cost${\lrcorner}$. During two years, this hospital has organized thirteen QC circles that were classified three categories according to that objective: four circles work for higher quality; the other four circles work for higher efficiency; five circles for lower cost. After implementation, several results were found from two viewpoints. From viewpoint of tangibility, one of the most outcomes is to reduce labor cost from 56 persons to 28 persons of temporary employees. From viewpoint of intangibility, the result was evaluated using radar chart to compare the difference after improvement. This paper is going to report the process of CQI for the hospital management because it is a new issue in Taiwan since 1997

  • PDF

Derivation of Factors for Improvement for Efficient Procurement and Lifting Management of Modular Construction (모듈러 건축공사의 조달 및 양중 효율화를 위한 중점개선 요구사항 도출)

  • Kim, Min Ju;Lee, Dongmin;Lim, Hyunsu;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.211-212
    • /
    • 2015
  • Procurement and lifting scheduling of modules and resources in modular construction, where modules that are manufactured from factory are delivered and assembled on site, is a crucial factor that determines the efficiency of the whole construction. However, previous studies have barely acknowledged the significance of resource procurement process and lifting of modules in modular construction. Therefore, this research aims to derive factors that are in need of improvement for successful implementation of procurement and lifting efficiency, and visualize them according to their importance and performance on improvement through IPA(Important Performance Analysis).

  • PDF

The research in rationalization of the use of energy in electric power (에너지 이용 합리화를 위한 전기에너지 사용계획 수립에 관한 연구)

  • Kim, Man-Kook;Nam, Si-Bok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.392-399
    • /
    • 2009
  • This study investigates and analyzed electrical energy curtailment effect by each business department and by energy use efficiency elevation equipment because do an energy use plan that is enforced in each variety business that is developed in domestic by model. When plan the recent electrical energy use with this, I wish to contribute in energy use general planning establishment improvement that is aiming energy efficiency improvement newly by groping improvement plan moment deduce problem. Specially, search present condition and problem by electrical energy curtailment equipment application that probes mass and analyzed, and is applied in present our country according to analysis contents to the latest energy use plan that was enforced on energy use rationality narration but allowed purpose.

  • PDF

Amplitude Modulation Response and Linearity Improvement of Directly Modulated Lasers Using Ultra-Strong Injection-Locked Gain-Lever Distributed Bragg Reflector Lasers

  • Sung, Hyuk-Kee;Wu, Ming C
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.303-308
    • /
    • 2008
  • Directly modulated fiber-optic links generally suffer higher link loss and larger signal distortion than externally modulated links. These result from the electron-photon conversion loss and laser modulation dynamics. As a method to overcome the drawbacks, we have experimentally demonstrated the RF performance of directly modulated, ultra-strong injection-locked gain-lever distributed Bragg reflector (DBR) lasers. The free-running DBR lasers exhibit an improved amplitude modulation efficiency of 12.4 dB under gain-lever modulation at the expense of linearity. By combining gain-lever modulation with ultra-strong optical injection locking, we can gain the benefits of both improved modulation efficiency from the gain-lever effect, plus improved linearity from injection locking. Using an injection ratio of R=11 dB, a 23.4-dB improvement in amplitude response and an 18-dB improvement in spurious-free dynamic range have been achieved.