• Title/Summary/Keyword: Improved Facility

Search Result 538, Processing Time 0.026 seconds

A Study on the Optimal Facility Layout Design Using an Improved Genetic Algorithm (개선된 유전자 알고리즘을 이용한 최적 공간 배치 설계에 관한 연구)

  • 한성남;이규열;노명일
    • Korean Journal of Computational Design and Engineering
    • /
    • v.6 no.3
    • /
    • pp.174-183
    • /
    • 2001
  • This study proposes an improved genetic algorithm (GA) to derive solutions for facility layout problems having inner walls and passages. The proposed algorithm models the layout of facilities on a flour-segmented chromosome. Improved solutions are produced by employing genetic operations known as selection, crossover, inversion, mutation, and refinement of these genes for successive generations. All relationships between the facilities and passages are represented as an adjacency graph. The shortest path and distance between two facilities are calculated using Dijkstra's algorithm of graph theory. Comparative testing shows that the proposed algorithm performs better than other existing algorithm for the optimal facility layout design. Finally, the proposed algorithm is applied to ship compartment layout problems with the computational results compared to an actual ship compartment layout.

  • PDF

Case Study on Facility Management for an Internation School (국제학교의 시설관리 사례연구)

  • Jang, Myung-Houn
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.97-98
    • /
    • 2016
  • It is important to manage an educational facility used by many students. The office of education has responsibility to manage public school facilities instead of most elementary, middle, and high schools. Some school or university outsources facility management and maintenance. An international school in Jeju is established by BTL (Build-Transfer-Lease) that includes construction and maintenance. This research objective is to analyze the case of facility management in the international school, and to provide improved method for school maintenance.

  • PDF

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

Case Study of Design and Implementation for Hadoop-Based Integrated Facility Monitoring System (하둡 기반의 통합설비 모니터링시스템 설계 및 구현 사례 연구)

  • Kim, Sangrak;Jang, Gilsang;Cho, Chiwoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • SCADA and DCS that have performed automatic control and monitoring activities increase the productivity of enterprise in industries. In such systems, although their performance had been improved, there are still many deficiencies in predictive maintenance which can foresee the risk of any kinds of accidents. Because the data acquisition systems of main facilities are being distributed throughout the whole plant and therefore, integration of data obtained from the systems is very difficult. Accordingly, techniques that acquire meaningful information from the gathered data through realtime analysis still need to be improved. This paper introduces a developed facility monitoring system which can predict equipment failure and diagnose facility status through big data analysis to improve equipment efficiency and prevent safety accidents.

Test Facility Improvement for Hot Firing Test of a 7-tonf Combustor (7톤급 연소기 시험을 위한 시험 설비 변경)

  • Kim, Hyeon-Jun;Lim, Byoung-Jik;Kang, Dong-Hyuk;Jae, Won-Ju;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.493-497
    • /
    • 2012
  • The rocket engine test facility(ReTF) was improved for hot firing tests of 7 ton-class liquid rocket engine combustion chamber, which will be used for the third stage of the Korea Space Launch Vehicle II(KSLV-II), considering convenience of operation and maintenance, flexibility and safety. In this paper, main modifications and functions of improved ReTF were described. 초 록

  • PDF

Improving the Measurement Uncertainty of Altitude Test Facility for Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Yoon, Min-Soo;Yang, In-Young;Jun, Young-Min;Yang, Soo-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.777-781
    • /
    • 2001
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of the gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 engine of Teledyne Co. as a facility checkout engine. Based on the test results, uncertainty analyses on the air flow rate and thrust were performed according to ASME PTC 19.1-1998. As the analyses showed that the level of uncertainty was not satisfactory over the whole operating envelop, several modifications of the facility and testing method were made in order to improve the measurement uncertainty. As a result, the uncertainty of the air flow measurement was improved by 0.1 % over all the test conditions, and the net thrust measurement by upto 3%. The improved measurement uncertainties of air flow and thrust are 0.68-0.73% and 0.4-1.3%, respectively.

  • PDF

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

Improvement for Classification System of Building Use on Neighborhood Living Facility (근린생활시설 용도분류체계 개선방안 연구)

  • Lee, Sung-Ok;Hwang, Eun-Kyoung
    • Journal of architectural history
    • /
    • v.21 no.6
    • /
    • pp.53-62
    • /
    • 2012
  • The purpose of this study is to present improvement for classification system of current neighborhood living facility to correspond rapid social change and various industries after understanding its status and problem. In current Building Standard Law, various kinds of buildings are classified for their structure, purpose of use, and building types. The Neighborhood Living Facility is divided into First Neighborhood Living Facility and Second Neighborhood Living Facility with applying area standards, according to facilities of convenience degree for neighborhood inhabitants. This classification, however, has problem in an arbitrary decision and applying of buildings without any definition or standards to adopt. And, there are some mixed neighborhood public functional facilities and amusement business affecting public morals among the Neighborhood Living Facility, so hazard environmental problems are also existed. According to the improved program, the study presents a prompt adoption of new facilities according to various industry increase, with minimum public discontent over adopted area standards. This study suggests making a clear scope through reclassification of Neighborhood Living Facility within the scope of the law on current Neighborhood Living Facility and an improvement plan of introducing necessary definitions on purpose of facility.

A Study on the Facility Standard of Herbal Dispensaries (탕전실의 시설 기준에 대한 연구)

  • Kim, Ji-Hoon;Kim, Yun-Kyung
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.81-92
    • /
    • 2017
  • Objectives: Herbal dispensaries can be installed separately from medical institutions. This study was done to suggest directions of regulation on management of externally installed herbal dispensaries. Methods: In this study, we visited and investrigated 7 representative herbal dispensaries to understand current status of herbal dispensaries. After comprehending current domestic regulations on herbal dispensaries, we referred "Management Practice on Dispensary Facility of Traditional Chinese Medicine in Medical Institution", "Enforcement Rule of Decree on Institution Standard of Manufacturing and Importation for Drugs, etc." and "Enforcement Rule of Food Sanitation Act" to suggest improved regulations for herbal dispensaries. Results: We suggested reasonable regulations for facility standards including location of building, dispensary room, water supply facility, lavatory and storage facility, etc.. Conclusions: We hope that results of this study could be baseline data for developing regulations on facility standards of herbal dispensaries.

Development of an Improved Inspection System for Slopes adjacent to Educational Facilities (개선된 교육시설 인접 사면 점검체계 구축)

  • Ko, Jun-Young;Lee, Joon-Kyu;Park, Ku-Byoung;Lee, Byoung-Ho;Kim, Jae-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.28 no.4
    • /
    • pp.3-10
    • /
    • 2021
  • This study presents an improved inspection system for slopes adjacent to educational facilities. For this, field investigations for 5 schools and 3 universities were performed to analyze the engineering stability of infrastructures, which ensure the safety of students and educational officers. Educational laws and the relevant enforcement are reviewed to understand the problems of current laws and enforcement. The results reveal that the engineering measures and reinforcement are required for the slopes of 36%. Also, the improvement of social awareness and regular inspection is needed to maintain the educational infrastructures. The suggested inspection system includes the fundamental and detailed checklists and guidance for non-engineering specialists.