• Title/Summary/Keyword: Implantitis

Search Result 141, Processing Time 0.027 seconds

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants

  • Kim, Ji-Hyun;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-Il;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.234-241
    • /
    • 2011
  • Purpose: One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on the microstructural changes in double acid-etched implant surfaces according to the laser energy and the application duration. Methods: The implant surface was irradiated using an Er:YAG laser with different application energy levels (100 mJ/pulse, 140 mJ/pulse, and 180 mJ/pulse) and time periods (1 minute, 1.5 minutes, and 2 minutes). We then examined the change in surface roughness value and microstructure. Results: In a scanning electron microscopy evaluation, the double acid-etched implant surface was not altered by Er:YAG laser irradiation under the condition of 100 mJ/pulse at 10 Hz for any of the irradiation times. However, we investigated the reduced sharpness of the specific ridge microstructure that resulted under the 140 mJ/pulse and 180 mJ/pulse conditions. The reduction in sharpness became more severe as laser energy and application duration increased. In the roughness measurement, the double acid-etched implants showed a low roughness value on the valley area before the laser irradiation. Under all experimental conditions, Er:YAG laser irradiation led to a minor decrease in surface roughness, which was not statistically significant. Conclusions: The recommended application settings for Er:YAG laser irradiation on double acid-etched implant surface is less than a 100 mJ/pulse at 10 Hz, and for less than two minutes in order to detoxify the implant surface without causing surface modification.

The Effects of a Er:YAG Laser on Machined, Sand-Blasted and Acid-Etched, and Resorbable Blast Media Titanium Surfaces Using Confocal Microscopy and Scanning Electron Microscopy

  • Park, Jun-Beom;Kim, Do-Young;Ko, Youngkyung
    • Journal of Korean Dental Science
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2016
  • Purpose: Laser treatment has become a popular method in implant dentistry, and lasers have been used for the decontamination of implant surfaces when treating peri-implantitis. This study was performed to evaluate the effects of an Erbium-doped:Yttrium-Aluminum-Garnet (Er:YAG) laser with different settings on machined (MA), sand-blasted and acid-etched (SA), and resorbable blast media (RBM) titanium surfaces using scanning electron microscopy and confocal microscopy. Materials and Methods: Four MA, four SA, and four RBM discs were either irradiated at 40 mJ/20 Hz, 90 mJ/20 Hz, or 40 mJ/25 Hz for 2 minutes. The specimens were evaluated with scanning electron microscopy and confocal microscopy. Result: The untreated MA surface demonstrated uniform roughness with circumferential machining marks, and depressions were observed after laser treatment. The untreated SA surface demonstrated a rough surface with sharp spikes and deep pits, and the laser produced noticeable changes on the SA titanium surfaces with melting and fusion. The untreated RBM surface demonstrated a rough surface with irregular indentation, and treatment with the laser produced changes on the RBM titanium surfaces. The Er:YAG laser produced significant changes on the roughness parameters, including arithmetic mean height of the surface (Sa) and maximum height of the surface (Sz), of the MA and SA surfaces. However, the Er:YAG laser did not produce notable changes on the roughness parameters, such as Sa and Sz, of the RBM surfaces. Conclusion: This study evaluated the effects of an Er:YAG laser on MA, SA, and RBM titanium discs using confocal microscopy and scanning electron microscopy. Treatment with the laser produced significant changes in the roughness of MA and SA surfaces, but the roughness parameters of the RBM discs were not significantly changed. Further research is needed to evaluate the efficiency of the Er:YAG laser in removing the contaminants, adhering bacteria, and the effects of treatment on cellular attachment, proliferation, and differentiation.

Randomized controlled clinical trial of 2 types of hydroxyapatite-coated implants on moderate periodontitis patients

  • Kim, Hyun-Suk;Yun, Pil-Young;Kim, Young-Kyun
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.5
    • /
    • pp.337-349
    • /
    • 2016
  • Purpose: The aim of this study was to compare and analyze the peri-implant tissue conditions and prospective clinical outcomes associated with 2 types of hydroxyapatite (HA)-coated implants: (1) fully HA-coated implants and (2) partially HA-coated implants with resorbable blast medium on the coronal portion of the threads. Methods: Forty-four partially edentulous patients were randomly assigned to undergo the placement of 62 HA-coated implants, and were classified as the control group (partially HA-coated, n=30) and the test group (fully HA-coated, n=32). All patients had chronic periodontitis with moderate crestal bone loss around the edentulous area. The stability and clinical outcomes of the implants were evaluated using the primary and secondary implant stability quotient (ISQ), as well as radiographic, mobility, and peri-implant soft tissue assessments around the implants. The Wilcoxon signed-rank test and the Mann-Whitney test were used to evaluate differences between and within the 2 groups, with P values <0.05 considered to indicate statistical significance. Results: The fully HA-coated implants displayed good retention of crestal bone, and insignificant differences were found in annual marginal bone loss between the 2 types of HA-coated implants (P>0.05). No significant differences were found in the survival rate (group I, 100%; group II, 100%) or the success rate (group I, 93.3%; group II, 93.8%). The fully HA-coated implants also did not significantly increase the risk of peri-implantitis (P>0.05). Conclusions: The fully HA-coated implants did not lead to an increased risk of peri-implantitis and showed good retention of the crestal bone, as well as good survival and success rates. Our study suggests that fully HA-coated implants could become a reliable treatment alternative for edentulous posterior sites and are capable of providing good retention of the crestal bone.

ER: YAG LASER IRRADIATED IMPLANT SURFACE OBSERVATION WITH SCANNING ELECTRON MICROSCOPY (Er: YAG 레이저 조사 임프란트 표면에 대한 전자주사현미경관찰)

  • Choi, Jung-Goo;Choi, Su-Jin;Min, Seung-Ki;Oh, Seung-Hwan;Kwon, Kyung-Hwan;Choi, Moon-Ki;Lee, June;Oh, Se-Ri
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.540-545
    • /
    • 2008
  • Since mid 20th century, dental treatments with laser have been introduced and improved a lot. Because early $CO_2$, Nd:YAG, diode, argon, and holmium lasers are used for dealing soft tissue, so it applied just limited field. But, in 1997 the lasers of erbium family that able to dealing soft and hard tissue also were introduced, laser application fields are enlarged. In today, the application fields reach on implantation treatment, so clinicians can use the laser to make holes for implantation, and flap elevation, even though treating peri-implantitis. So our class want to discover the optimal setting of Er:YAG laser when treating peri-implantitis. We observed the surface that initially treated by RBM and TPS passion and laser with varied options of exposure time and power with SEM image. For this we conclude the optimal setting range that does not alter the implant surface structure and report it.

Prevalence of Porphyromonas gingivalis fimA genotypes in peri-implant sulcus of Koreans using new primer

  • Kim, Sung-Geun;Hong, Ji-Youn;Shin, Seung-Il;Moon, Ji-Hoi;Lee, Jin-Yong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: Porphyromonas gingivalis fimA is a virulence factor associated with periodontal diseases, but its role in the pathogenesis of peri-implantitis remains unclear. We aimed to evaluate the relationship between the condition of peri-implant tissue and the distribution of P. gingivalis fimA genotypes in Koreans using a new primer. Methods: A total of 248 plaque samples were taken from the peri-implant sulci of 184 subjects. The control group consisted of sound implants with a peri-implant probing depth (PD) of 5 mm or less with no bleeding on probing (BOP). Test group I consisted of implants with a peri-implant PD of 5 mm or less and BOP, and test group II consisted of implants with a peri-implant PD of more than 5 mm and BOP. DNA was extracted from each sample and analyzed a using a polymerase chain reaction (PCR) with P. gingivalis -specific primers, followed by an additional PCR assay to differentiate the fimA genotypes in P. gingivalis-positive subjects. Results: The Prevalence of P. gingivalis in each group did not significantly differ (P>0.05). The most predominant fimA genotype in all groups was type II. The prevalence of type Ib fimA was significantly greater in test group II than in the control group (P<0.05). Conclusions: The fimA type Ib genotype of P. gingivalis was found to play a critical role in the destruction of peri-implant tissue, suggesting that it may be a distinct risk factor for periimplantitis.

The effects of tetracycline-HCI on SLA implant surface structure (염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향)

  • Sea, Mi-Ran;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.

The influence of tetracycline-HCI for micromorphology of Thermal dual acid etched surface implants (염산 테트라싸이클린이 이중 산부식 임플란트 표면 구조에 미치는 영향)

  • Jeong, Do-Min;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.265-275
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Implants with thermal dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ Tetracycline-HCI solution and sterilized saline for O.5min, 1min, 1.5min, 2min, 2.5min and 3min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation and measured surface roughness by optical interferometer. The results of this study were as follows. 1. The thermal dual acid etched surfaces showed many small peaks and valleys distributed overall surface. 2. The surface conditioning with Tetracycline-HCI and saline didn't influence on its micromorphology. In conclusion, the implant with thermal dual acid etched surface has a protective micromorphology from the detoxification with $50mg/m{\ell}$ Tetracycline-HCI and a scrubbing with cotton pellet. Therefore, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI is an effective method for peri-implantitis in case implants with thermal dual acid etched surface.

Decontamination methods to restore the biocompatibility of contaminated titanium surfaces

  • Jin, Seong-Ho;Lee, Eun-Mi;Park, Jun-Beom;Kim, Kack-Kyun;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.193-204
    • /
    • 2019
  • Purpose: The reaction of cells to a titanium implant depends on the surface characteristics of the implant which are affected by decontamination. The aim of this study was to evaluate the cytocompatibility of titanium disks treated with various decontamination methods, using salivary bacterial contamination with dental pellicle formation as an in vitro model. Methods: Sand-blasted and acid-etched (SA) titanium disks were used. Three control groups (pristine SA disks [SA group]; salivary pellicle-coated SA disks [pellicle group]; and biofilm-coated, untreated SA disks [NT group]) were not subjected to any decontamination treatments. Decontamination of the biofilm-coated disks was performed by 14 methods, including ultrasonic instruments, rotating instruments, an air-powder abrasive system, a laser, and chemical agents. MG63 cells were cultured in the presence of the treated disks. Cell proliferation assays were performed on days 2 and 5 of cell culture, and cell morphology was analyzed by immunofluorescence and scanning electron microscopy (SEM). A vascular endothelial growth factor (VEGF) assay was performed on day 5 of culture. Results: The cell proliferation assay revealed that all decontaminated disks, except for the 2 groups treated using a plastic tip, showed significantly less cell proliferation than the SA group. The immunofluorescence and SEM analyses revealed that most groups showed comparable cell density, with the exception of the NT group, in which the cell density was lower and bacterial residue was observed. Furthermore, the cells grown with tetracycline-treated titanium disks showed significantly lower VEGF production than those in the SA group. Conclusions: None of the decontamination methods resulted in cytocompatibility similar to that of pristine SA titanium. However, many methods caused improvement in the biocompatibility of the titanium disks in comparison with the biofilm-coated, untreated titanium disks. This suggests that decontamination is indispensable for the treatment of peri-implantitis, even if the original biocompatibility cannot be restored.

Evaluation of the effectiveness of diode laser therapy in conjunction with nonsurgical treatment of periimplantitis

  • Dicle Altindal;Eylem Ayhan Alkan;Metin Calisir
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.376-387
    • /
    • 2023
  • Purpose: Peri-implantitis (PI) is an inflammatory condition associated with the destruction of bone tissue around a dental implant, and diode lasers can be used to treat this disease. In this study, we aimed to evaluate the effectiveness of a 940-nm diode laser for the nonsurgical treatment of PI. Methods: Twenty patients (8 women and 12 men) were enrolled in a split-mouth randomized controlled study. In the control group (CG), mechanical debridement with titanium curettes accompanied by airflow was performed around the implants. The test group (TG) was treated similarly, but with the use of a diode laser. Clinical measurements (plaque index, gingival index [GI], probing pocket depth [PPD], bleeding on probing [BOP], clinical attachment level, and interleukin-1β [IL-1β] in the peri-implant crevicular fluid) were evaluated and recorded at baseline and 3 months. IL-1β levels were determined using the enzyme-linked immunosorbent assay method. Results: The symptoms were alleviated in both groups at 3 months as assessed through clinical measurements. GI, BOP, and PPD were significantly lower in the TG than in the CG (P<0.05). The IL-1β level increased post-treatment in both groups, but this increase was only statistically significant (P<0.05) in the CG. Conclusions: The diode laser enabled improvements in clinical parameters in the periimplant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.