Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

  • Sen, Nazmiye;Sermet, Ibrahim Bulent;Gurler, Nezahat
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2019
  • PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with $0.7{\mu}L$ of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in ${\mu}m$) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

External vs internal implant : 각각의 장점과 고려사항 (External vs internal connection implant system)

  • 성동재;홍성진;하승룡
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구 (THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT)

  • 임재빈;임순호;조인호
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

Effect of initial placement level and wall thickness on maintenance of the marginal bone level in implants with a conical implant-abutment interface: a 5-year retrospective study

  • Yoo, Jaehyun;Moon, Ik-Sang;Yun, Jeong-Ho;Chung, Chooryung;Huh, Jong-Ki;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제49권3호
    • /
    • pp.185-192
    • /
    • 2019
  • Purpose: Implant wall thickness and the height of the implant-abutment interface are known as factors that affect the distribution of stress on the marginal bone around the implant. The goal of this study was to evaluate the long-term effects of supracrestal implant placement and implant wall thickness on maintenance of the marginal bone level. Methods: In this retrospective study, 101 patients with a single implant were divided into the following 4 groups according to the thickness of the implant wall and the initial implant placement level immediately after surgery: 0.75 mm wall thickness, epicrestal position; 0.95 mm wall thickness, epicrestal position; 0.75 mm wall thickness, supracrestal position; 0.95 mm wall thickness, supracrestal position. The marginal bone level change was assessed 1 day after implant placement, immediately after functional loading, and 1 to 5 years after prosthesis delivery. To compare the marginal bone level change, repeated-measures analysis of variance was used to evaluate the statistical significance of differences within groups and between groups over time. Pearson correlation coefficients were also calculated to analyze the correlation between implant placement level and bone loss. Results: Statistically significant differences in bone loss among the 4 groups (P<0.01) and within each group over time (P<0.01) were observed. There was no significant difference between the groups with a wall thickness of 0.75 mm and 0.95 mm. In a multiple comparison, the groups with a supracrestal placement level showed greater bone loss than the epicrestal placement groups. In addition, a significant correlation between implant placement level and marginal bone loss was observed. Conclusions: The degree of bone resorption was significantly higher for implants with a supracrestal placement compared to those with an epicrestal placement.

국산 내부연결형 임플란트시스템(GS II$^{(R)}$)에서 지대주 연결방식에 따른 응력분석에 관한 연구 (Three-Dimensional Finite Element Analysis of Internal Connection Implant System (Gsii$^{(R)}$) According to Three Different Abutments and Prosthetic Design)

  • 장미라;곽주희;김명래;박은진;박지만;김선종
    • 구강회복응용과학지
    • /
    • 제26권2호
    • /
    • pp.179-195
    • /
    • 2010
  • 임플란트 보철물에 저작력 등 외부 하중이 작용하면 내부 반응으로 응력이 발생되는데 지지골에 나타난 응력은 골재생 및 흡수 파괴, 임플란트에 나타난 응력은 임플란트 자체의 파절이나 나사의 풀림현상 및 파절, 상부 구조물에 나타난 응력은 보철물의 파절 등을 예견하는 지침이 될 수 있을 것이다. 지대주의 형상과 재질에 따라 연결방법과 보철방법이 달라지고 임플란트 내부의 하중전달 기전이 변하게 되고 이에 따라 악골에 발생하는 응력분포 역시 달라질 수 있다. 본 연구에서는 하악 제 1대구치 부위에 이중나사 구조를 갖고 원추형 내측연결 임플란트 시스템인 GSII$^{(R)}$ (Osstem, Korea)임플란트를 이용해 지대주의 종류를 티타늄 소재의 2-piece Transfer$^{TM}$ abutment (GST), 금합금 소재의 2-piece GoldCast$^{TM}$ abutment(GSG), 외부 연결형태를 가진 3-piece Convertible$^{TM}$ abutment (GSC) 로 분류하여 이에 따른 응력분포 양상을 비교 분석하여 보았다. 결과 하중조건에 관계없이 응력은 주로 지대주와 고정체가 접촉하는 경부에 집중되었다. 또한 하중조건에 관계없이 임플란트의 고정체 상부와 접촉하는 치밀골에 높은 응력이 나타나고 해면골에는 아주 작은 응력이 나타났다. 축하중보다는 중심축을 벗어난 하중조건에서 더 높은 응력이 발생되었고 수직하중보다 경사하중에서 더 높은 응력이 발생되었다. 전체에 걸친 최대응력은 GSG에서는 지대주, 치관 및 고정체에 고르게 분포되었고 GST는 주로 고정체와 지대주 나사에, GSC는 고정체와 지대주에 집중되었다. 세 지대주 간 골내의 최대응력에는 유의한 차이가 없었고 GSG가 전체 구성부의 응력분포에 있어 유리한 것으로 나타났다.

Comparative study of abutment screw loosening with or without adhesive material

  • Arshad, Mahnaz;Shirani, Gholamreza;Refoua, Sina;Yeganeh, Mohammadreza Rahimi
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.99-103
    • /
    • 2017
  • PURPOSE. The purpose of this study was to achieve more retention and stability and to delay or prevent screw loosening. MATERIALS AND METHODS. Twenty implants (Implantium 3.4 mm, Dentium, Seoul, Korea) were divided into 2 groups (n = 20). In the first group, an adhesive material was applied around the screw of the abutments (test group). In the second group, the screws are soaked in saliva (control group). All the screws were torqued under 30 N/cm, Then, the samples were gone through a cyclic fatigue loading process. After cyclic loading, we detorqued screws and calculated detorque value. RESULTS. In comparison with the control group, all the implant screws in the test group were smeared with the adhesive material, showing significant higher detorque value. CONCLUSION. There are significantly higher detorque values in the group with adhesive. It is recommended to make biocompatible adhesive to reduce screw loosening.

테이퍼드 직선형 SLA 임플란트의 안정성 평가 (Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design)

  • 김용건;이규복
    • 구강회복응용과학지
    • /
    • 제34권2호
    • /
    • pp.80-88
    • /
    • 2018
  • 목적: 임플란트 표면의 특성과 임플란트 디자인은 성공적인 초기 고정을 얻는데 중요한 변수이다. 이 연구의 목적은 치유기간 동안 테이퍼드 직선형 디자인을 가진 SLA (Sandblasted and Acid-etched) 임플란트의 ISQ (Implant Stability Quotient) 값을 측정하고 임플란트의 안정성에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 임플란트의 안정성을 측정하기 위하여 26명의 환자(여자 13명, 남자 13명)의 44개 임플란트에 대한 자기공명주파수분석(Resonance Frequency Analysis)을 실시하였다. 골질 및 골량에 대한 임상적 평가는 Lekholm & Zarb (1985)의 기준에 따라 시행하였다. 시간경과에 따른 임플란트 안정성변화(총 ISQ 값)를 고정체 식립 시 그리고 12주후 치유지대주 연결 시 측정하고 RFA와 식립토크, RFA와 골질, RFA와 상, 하악골 사이의 상관관계를 평가하였다. 결과: 임플란트의 평균 ISQ값은 임플란트 식립 당시(기준선) $69.4{\pm}10.2$, 치유지대주연결에서(두번째수술) $81.4{\pm}6.9$였다(P < 0.05). RFA와 골질, RFA와 상하악골 사이에 유의한 차이가 있었다(P < 0.05). RFA와 식립토크, 식립부위, 고정체 직경, 임플란트 길이 사이에는 유의한 차이가 없었다(P > 0.05). 결론: 본 연구의 제한된 범위내에서 테이퍼드 직선형 디자인을 가진 SLA 임플란트의 ISQ값은 고정체 식립시와 치유지대주 연결 시 모두 높은 값을 보였다. 따라서 테이퍼드 직선형 디자인을 가진 SLA 임플란트는 초기안정성 및 2차 안정성을 향상시킬 수 있으며, 즉시 또는 초기하중을 적용할 수 있을것으로 사료된다.

임플랜트 유지 나사 머리 홈의 설계가 나사를 푸는 시간에 미치는 영향에 관한 연구 (PRELIMINARY STUDY ON THE DESIGN OF IMPLANT ABUTMENT SCREW HEAD FOR RAPID FASTENING & LOOSENING)

  • 이재봉
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.193-200
    • /
    • 2002
  • For the purpose of decreasing the chair time in implant cases, the time needed to loosening and fastening the screw must be shortened. Nowadays, the two typical designs of screw head are slot and hexa form. This study aimed at the shortening of loosening and fastening time by modifying the slot and hexa form. Total of twelve dentists participate in these experiments, four of them were experienced and eight of them were novice dentists. 1. There were many differences in the speeds of screw loosening and fastening between personal experiences. Experienced dentists are faster than novice dentists. 2. There were many differences in the speeds by angulation of the implant, by the conditions of the muscle tonicity. 3. Revised slot and hexa Heads show the slightly shortened time for acrew looseing and fastening.

두 종류 치과 임플란트 캐드 소프트웨어의 사용자 편의성 및 만족도 비교 (Evaluating usability of and satisfaction with two types of dental CAD software)

  • 김성민;이완선;손큰바다;이규복
    • 구강회복응용과학지
    • /
    • 제35권1호
    • /
    • pp.11-19
    • /
    • 2019
  • 목적: 치과 임플란트 캐드 소프트웨어를 사용해 본 경험자와 무경험자에 의한 두 종류 캐드 소프트웨어의 사용자 편의성 및 만족도를 평가하는 것이다. 연구 재료 및 방법: 치과 임플란트 캐드 소프트웨어에 경험이 있는 20명의 치기공사와 캐드 소프트웨어를 사용해보지 않은 12명의 경북대학교 치과대학 학생에게 두 종류의 캐드 소프트웨어(ExoCad, Deltanine)를 이용하여 임플란트 맞춤 지대주(implant custom abutment)를 디자인하도록 하였다. 그리고 구조화된 설문지(1단계: 기본 정보 및 파일 불러오기, 2단계: 지대주 디자인 전 조건 설정, 3단계: 지대주 디자인 설정, 4단계: 전체적인 만족도)를 작성하도록 하였다. 수집된 자료의 통계분석은 Mann-Whitney U test를 사용하였다(${\alpha}=.05$). 결과: 4단계로 나누어 진 21개 문항에 대해 평가된 치과 임플란트 캐드 소프트웨어의 디자인 편의성과 만족도는 1단계의 두 문항에서 모두 Exocad 소프트웨어에서 유의하게 높았습니다. 2단계 및 3단계의 경우 경험이 있는 참가자는 Deltanine 소프트웨어가 훨씬 뛰어나다고 평가했습니다. 4단계에서는 두 문항 모두 Exocad 소프트웨어에서 높은 평가를 받았습니다. 결론: 2 종류 치과 임플란트 캐드 소프트웨어의 편의성 및 만족도 조사에서 Exocad 소프트웨어가 전체적으로 높은 평가를 받았다. 하지만 디자인 과정 중 핵심인 2, 3단계에서 유경험자는 Deltanine 소프트웨어를 높게 평가하였다. 따라서 그외 부분을 보강하면 Deltanine 소프트웨어는 임상에서 널리 사용될 수 있을 것이다.

연조직 공간을 허용하는 맞춤형 보철 수복을 통한 임플란트 주위 합병증의 개선 증례 (Improvement of peri-implant complications through customized prosthesis restoration allowing soft tissue space: a case report)

  • 송지은;장우형;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.260-266
    • /
    • 2023
  • 'Implant Supracrestal Complex (ISC)'의 개념은 임플란트 보철물의 디자인 형태가 단기 임상 결과와 임플란트 주변 경·연조직의 장기 예후에 미치는 영향을 확인하는 방법으로 도입되었다. 임플란트-지대주 디자인과 접합부(junction) 및 위치와 같은 임플란트-보철물-지대주 복합 디자인 형태는 임플란트 주변 조직의 장기적인 유지에 중요한 영향을 미칠 수 있다. 본 증례에서는 임플란트 보철물 수복 후 만성적인 연조직 염증이 발생한 환자에게 오목한 맞춤형 지대주와 출현각이 30도를 이루는 보철물을 수복하였다. 새로운 보철물은 충분한 경·연조직 공간을 확보하고 적절한 연조직 폐쇄를 이룸에 따라 합병증이 개선되고 임플란트의 장기적인 안정성을 유지하는 것을 확인하였다.