FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system) (개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례)

  • Hong, Tae-Young;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.423-430
    • /
    • 2016
  • The implant prosthesis can be divided into the screw retained prosthesis and cement retained prosthesis. Each type has advantages as well as disadvantages which is unfavorable to maintain the implants. To overcome these drawbacks, T-screw system was developed. T-screw system which utilizes a lingual direction of the screw to retain the implant prosthesis, has advantages of retrievability of the prosthesis, passive fit, and possibility to form esthetic and functional occlusal surface. The prior prosthesis which utilized horizontal screws had difficulty in fabrication especially in the case of multiple units, and also limited use with all-ceramic prosthesis. In this case, fabricating the implant prosthesis by using the T-screw system showed superior results in easy maintenance, esthetics, and also functions. In addition, we are to report the method of using the T-screw system in implant prosthesis, such as multiple units of implant prosthesis and all ceramic prosthesis.

External vs internal connection implant system (External vs internal implant : 각각의 장점과 고려사항)

  • Seong, Dong-Jae;Hong, Seoung-Jin;Ha, Seung-Ryong
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

Multicentric retrospective clinical study on the clinical application of mini implant system (미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구)

  • Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin;Kim, Un-Kyu;Moon, Kyung-Nam;Jeon, Seung-Joon;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.325-330
    • /
    • 2010
  • Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.

The comparative study of user satisfaction on various implant engine system (다양한 임플란트 엔진 시스템에 대한 사용자 만족도 비교)

  • Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.9-15
    • /
    • 2014
  • Purpose: Implant engine system is composed of the handpiece, micromotor, control box and foot switch. The aim of this study was to evaluate the satisfaction of the implant engine systems in terms of convenience-design and to examine the relation with the experience of implant surgery. Materials and Methods: Three implant systems were evaluated: SurgicXT/X-SG20L, INTRAsurg300/CL3-09, XIP10/CRB26LX. For this comparative study, 30 dentists were included and the satisfaction was measured using a structured questionnaire. One-way analysis of the variance (ANOVA) and multiple regression analysis were used within and between the groups. Results: Total satisfaction differed from each other (P < 0.05). The convenience score was more associated with the total satisfaction than design score. Moreover, the implant surgery experience affected several assessments. Conclusion: Collectively, in a cross-sectional study model, the design of implant system significantly affects its total satisfaction and the surgery experience can be influential factor in the evaluation of implant engine system.

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

Clinical evaluation of $Br{\aa}nemark$ Ti-Unite implant and ITI SLA implant in the post maxillary area with sinus elevation technique. (상악동 거상술을 이용하여 구치부에 식립된 $Br{\aa}nemark$ Ti-Unite와 ITI SLA 임플란트의 임상적 평가)

  • Hong, Seong-Bae;Chai, Gyung-Joon;Jung, UI-Won;Kim, Chang-Sung;Chim, Joon-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.813-822
    • /
    • 2005
  • The predictable outcome of implant placement in the atrophic maxilla with sinus floor elevation procedure(osteotome sinus floor elevation technique and window opening technique) is well documented. Aim of this study was to evaluate the efficacy of $Br{\aa}nemark$ Ti-Unite implant system and ITI SLA implant system placed in the atrophic posterior maxilla with sinus floor elevation procedure. Eighty patients received placement of $Br{\aa}nemark$ Ti-Unite implants(195 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(153 osteotome sinus floor elevation technique and 42 window opening procedure). Fifty patients received placement of ITI SLA implants(83 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(77 osteotome sinus floor elevation technique and 6 window opening procedure). Chart review were taken from each patient. The total failed implants were seven and the total implant survival rate was 96.4% in $Br{\aa}nemark$ Ti-Unite system. The total failed implants were one and the total implant survival rate was 98.8% in ITI SLA system. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in $Br{\aa}nemark$ Ti-Unite system. The implant survival rate with osteotome technique was 98.7% and 100% with window opening. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in ITI SLA system. The results of this evaluation show that the placement of $Br{\aa}nemark$ Ti-Unite system as well as ITI SLA system is a reasonable treatment option for patients with the atrophic posterior maxillary area.

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

  • Kim, Min-Jeong;Hong, Sung-Ok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.85-93
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone.

INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY (임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향)

  • Oh, Gap-Yong;Park, Sung-Hwa;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.