• 제목/요약/키워드: Implant supported dental prosthesis

검색결과 149건 처리시간 0.022초

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.

Implant complications in bruxism patients

  • Song, Ji-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권2호
    • /
    • pp.149-150
    • /
    • 2021
  • Bruxism is defined as a parafunctional activity during sleep or while awake that includes locking and grinding of teeth and clenching. It generates excessive occlusal force that may lead to implant failure. Therefore, diagnosis of bruxism and providing specific protocols such as occlusal splint and/or injection of botulinum toxin before implant installation are important to prevent increases the risk of implant failure in bruxism patients.

임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고 (Axial displacement in single-tooth implant restoration: Case report)

  • 정승회;김선재;장재승
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.126-133
    • /
    • 2021
  • 여러 연구에서 임플란트 지지 보철물의 수직 침하에 대해 보고되고 있지만, 구강내 임플란트 지지보철물의 기능 시 수직침하 양상에 대해서는 알려진 바 없다. 본 증례에서는 2명의 환자에서 구치부 단일 치아 임플란트 지지 보철물의 3차원적인 변화를 평가하였다. 내부연결형 임플란트를 식립하였으며 통상적인 방법으로 Screw-Cement Retained Prosthesis(SCRP) 형태의 보철물을 제작해 장착하였다. 구강스캐너(Cerec Omnicam, Dentsply Sirona, USA)를 이용해 보철물 장착 시, 장착 1주, 1개월, 1년 후 구강 스캔을 시행하였으며 디지털 분석 프로그램(Geomagic Control X, 3D systems, USA)을 이용해 기간에 따른 위치 변화를 3차원적으로 평가하였다. 인접 치아를 기준으로 보철물 장착 후 임상적인 위치 변화가 나타났으며 변화량은 시간이 지남에 따라 증가하였다.

Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

  • Yuan, Judy Chia-Chun;Sukotjo, Cortino
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.51-57
    • /
    • 2013
  • Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices.

치조제가 심하게 흡수된 하악 무치악환자의 나사-시멘트 유지형 임플란트 보철 수복증례 (Screw and cement retained implant prosthesis rehabilitation of mandibular edentulous patients with severely absorbed ridge)

  • 임중재
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.149-156
    • /
    • 2019
  • Purpose: Prosthodontics for edentulous patients is a treatment technique using implant, which has impactful results in retention and support effects. Methods: As a retention technique, SCRP (screw and cement retained implant prosthesis) has reported in many studies as a beneficial method for both patients and curers, which can reduce errors in process of making abutment and top implant. Results: Prosthesis manufacturing, as polymerization method of hardened resin teeth with thermoplastic resin, is helpful for patients with aesthetic and financial situations regarding residual ridge and interocclusal relationship, also indicates reliable results in both retention and care. Conclusion: Using SCRP technique, we notably obtained a clinical and aesthetic outcome from five implants in anterior tooth, which are half fixable and detachable implants on screw of implant abutment by the technicians at anytime.

적합도가 다른 임플랜트 지지 보철물의 삼차원적 응력 분석 (Three dimensional stress analysis of implant-supported prosthesis with various misfit)

  • 양홍서;정현주;박영준;박상원
    • 구강회복응용과학지
    • /
    • 제17권4호
    • /
    • pp.307-314
    • /
    • 2001
  • To evaluate the effect of misfit in two implant-supported fixed partial dentures in the posterior of the mandible, variations of the standard finite element models were made by changing the location of the gap as follows: 1) no gap present; 2) located between the gold cylinder and the abutment on the distal implant; 3) gap located between the gold cylinder and the abutment on the mesial implant. The results of this study were as follows: 1. When the location of the gap was close to the load applied on the prosthesis, the stress in the prosthesis, implant components and surrounding bone increased. 2. The presence of cantilever increased the stress in the prosthesis, implant and surrounding bone significantly, regardless of the presence of the gap. 3. When there was a gap between the prosthesis and abutment, the stress in the bone around the implant increased. 4. When passive fit was achieved, the stress was distributed widely in each component with less peak stress in each component. 5. The inner structures of the implant components, the gold screw and the abutment screw bear more stress when the prosthesis did not exhibit passive fit with the abutments than when passive fit was present.

  • PDF

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Finite element analysis in static and dynamic behaviors of dental prosthesis

  • Djebbar, N.;Serier, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.65-78
    • /
    • 2015
  • In recent years, implants have gained growing importance in all areas of medicine. The success of the treatment depends on many factors affecting the bone-implant, implant-abutment and abutment-prosthesis interfaces. In this paper, static and dynamic behaviors of the dental prosthesis are investigated. Three-dimensional finite element models of dental prosthesis were constructed. Dynamic loads in 5 sec applied on occlusal surface. Therefore, FEA was selected for use in this study to examine the effect of the static and dynamic loads on the stress distribution for an implant-supported fixed partial denture and supporting bone tissue.

고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례 (Full mouth rehabilitation of edentulous patient with fixed implant prosthesis)

  • 신희현;김종진;백진;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제37권3호
    • /
    • pp.147-156
    • /
    • 2021
  • 완전 무치악 환자의 구강 회복은 통상적 총의치, 하이브리드 보철물, 임플란트 지지 고정성 보철물 등 다양한 치료 옵션을 통해 이루어질 수 있다. 전악 임플란트 고정성 보철 수복의 경우 가철성 수복과 비교해 최종적인 보철물의 형태를 고려하여 정확한 위치에 임플란트를 식립해야 한다는 어려움이 따른다. 본 증례에서는 치아우식과 만성 치주염으로 전악 발거를 요하는 환자의 전악 임플란트 고정성 수복을 진행하였다. 임플란트 식립 단계에서 최종 보철물 형태를 고려하여 제작된 수술용 가이드를 이용하여 원하는 위치에 임플란트를 식립 하였으며 고정성 임시 수복물 단계에서 수정 및 재제작을 통해 기능과 심미를 평가하였다. 이렇게 제작된 임시 수복물을 바탕으로 금속 도재관의 최종 수복물을 장착하였다. 나사 풀림 및 도재 파절 등의 합병증에 대처하기 위해 구치부의 경우 나사 유지형 보철물, 전치부는 나사 시멘트 유지형 보철물로 제작하였다. 그 결과 환자는 최종 보철물 장착 후 기능적 심미적 측면에서 개선된 예후를 보였다.