• Title/Summary/Keyword: Implant prostheses

Search Result 322, Processing Time 0.033 seconds

Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.351-360
    • /
    • 2020
  • PURPOSE. The aim of the present study was to compare the stress distributions on the dental implants, abutments, and bone caused by different overdenture attachment types under functional chewing forces. MATERIALS AND METHODS. The 3D finite element models of the mandible, dental implants, attachment types, and prostheses were prepared. In accordance with a conventional dental implant supported overdenture design, the dental implants were positioned at the bone level in the canine teeth region bilaterally. A total of eight models using eight different attachment systems were used in this study. All the models were loaded to simulate chewing forces generated during the centric relationship (450 N), lateral movement (400 N), protrusive movement (400 N), and also in the presence of a food mass unilaterally (200 N). Stress outputs were obtained as the maximum principal stress and the equivalent von-Mises stress. RESULTS. In all attachment types, higher stress values were observed in the abutments, dental implants, and bone in the magnet attachments in different loading conditions. The highest stress values were observed among the magnet systems in the components of the Titanmagnetics model in all loading conditions (stresses were 15.4, 17.7, and 33.1 MPa on abutment, dental implant, and bone, respectively). The lowest stress value was observed in the models of Zest and O-Ring attachments. CONCLUSION. The results of the present study implied that attachment types permitting rotation and tolerating various angles created lower stresses on the bone, dental implants, and abutments.

Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique (컴퓨터 시뮬레이션 기반의 외과용 스텐트를 이용한 임플란트 시술과 영상융합기술을 이용한 평가)

  • Lee, Jee-Ho;Kim, Soung-Min;Paeng, Jun-Young;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.402-407
    • /
    • 2010
  • Introduction: The planning of implant surgery is an important factor for the implant prosthesis. Stereolithographic (SLA) surgical stents based on a computer simulation are quite helpful for clinicians to perform the surgery as planned. Although many clinical and technical trials have been performed for computed tomography (CT)-guided implant stents to improve the surgical procedures and prosthetic treatment, there are still many problems to solve. We developed a system of a surgical guide based on 3 dimensional (3D) CT for implant therapy and achieved satisfactory results in the terms of planning and operation. Materials and Methods: Fifteen patients were selected and 30 implant fixtures were installed. The preoperative CT data for surgical planning were prepared after obtaining informed consent. Surgical planning was performed using the simulation program, Ondemend3D In2Guide. The stents were fabricated based on the simulation data containing information of the residual bone, the location of the nerve, and the expected design of the prostheses. After surgery with these customized stents, the accuracy and reproducibility of implant surgery were evaluated based on the computer simulation. The data of postoperative CT were used to confirm this system using the image fusion technique and compare the implant fixtures between the planned and implanted. Results: The mean error was 1.18 (${\pm}0.73$) mm at the occlusal center, 1.23 (${\pm}0.67$) mm at the apical center, and the axis error between the two fixtures was $3.25^{\circ}C$ (${\pm}3.00$). These stents showed superior accuracy in maxilla cases. The lateral side error at the apical center was significantly different from the error at the occlusal center but there were no significant differences between the premolars, 1st molars and 2nd molars. Conclusion: SLA surgical stents based on a computer simulation have the satisfactory accuracy and are expected to be useful for accurate planning and surgery if some errors can be improved.

A STUDY OF CLINICAL RESULTS ON STERI-OSS ENDOSSEOUS IMPLANTS (Steri-Oss 임플랜트의 임상 결과에 관한 연구)

  • Min, Young-Kyu;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.258-272
    • /
    • 1998
  • This investigation evaluated patients who received Steri-Oss implants from the Dental Hospital of Chosun University during the period from March 1989 to August 1997. 346 fixtures of 127 patients were included in this study. The results were as follows ; 1.The follow-up period was defined as the period between the surgical placement of the implants and the last follow-up examination. The mean follow-up period was $2.17{\pm}1.21$ years. 2.The period between fixture installation and second surgery was $0.71{\pm}0.44$ years in the maxilla and $0.46{\pm}0.21$ years in the mandible. 3.The number of fixtures which were installed in the upper jaw(112) was less than that in the lower jaw(234) and in the posterior region(260) was more than in the anterior region(86). 4.The length of fixture which was most frequently used was 12 mm and least was 8mm. Screw implants were installed more than cylindrical implants. 3.8mm implant was the most common implans, followed by 4.5mm and 3.25mm. 5.The number of augmentation cases was more than that of non-augmentation cases and the rate of augmentation cases in the maxilla was more than that in the mandible. 6.Implant restorations for partial edentulos patients(94cases) were more than single- tooth implant restorations(33cases) or implant restorations for complete edentulos patients(10cases). 7.Free-standing prostheses for partially edentulous patients were more commom than any other type of connection between implants and natural teeth. 8.Plaque Index($0.95{\pm}0.74$) and Gingival Index($0.31{\pm}0.52$) were very similar around the natural teeth and reflected an acceptable level of plaque and gingivitis control. Mean value for keratinized mucosa index($1.93{\pm}1.20$) remained fairly constant around level 2(1-2 mm keratinized epithelium). 9.Patients were generally satisfied with implant in terms of comfort, function, speech and esthetics. 10.There was not a statistically significant differences in overall survial rate between implants placed in the maxilla (91.5%) and those placed in the mandible (93.8%). Fourteen implants lost before the prosthetic rehabilitation and eleven implants lost following variable periods in function after the prosthetic phase of the treatment. 11.Cause of implant failures was exfoliation or removal of fixture due to non-osseointegration before the prosthetic rehabilitation or due to fracture of fixture, masticatory pain after the prosthetic rehabilitation. 12.The survival rate of Steri-Oss implants using the Kaplan-Meier statistical analysis was 93.8% at 2 year and 86.6% at 5 year, In all cases, implant losses occured predominantly in the healing period. There was a steep decline in the rate of implant loss after the first year. 13.The survival rate of Steri-Oss implants in the anterior region was 94.8% at 2 year and 94.8% at 5 year and that in the posterior region was 92.8% at 2 year and 75.9% at 5 year. In conclusion, this study revealed a number of parameters and guidelines for achieving an optimal success rate in osseointegration.

  • PDF

STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE (하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화)

  • Jung, Hye-Eun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

The Factors Influencing to the Implant Patients Discomfort (임플란트 식립 후 불편감에 영향을 주는 요인)

  • Yoon, Hyun-Seo;Heo, Soo-Hee;Chun, Jin-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.325-332
    • /
    • 2011
  • To get the evidences for decreasing the discomfort, dissatisfaction, and for improving management of the implant prothesis through assessment implant patients' awareness and discomforts about care of the prostheses. The subjects were 300 implant patients who treated in the 20 dental clinics in Pusan, Ulsan and Daegu. The general characteristics, recognition, maintenance, discomfort and dissatisfaction, and oral hygiene status were collected. Level of the discomfort and dissatisfaction was measured by a 5 Likert scale, and analyzed by the equivalent of 100. The life-span of the implants was overestimated, however, periodic recall check and scaling were underwent. The level of discomfort and dissatisfaction was generally good, but many of them (65.3%) complained the food impaction. As a result of the multiple regression analysis, level of the discomfort and dissatisfaction increased in case of more number of the prosthesis ($\beta$=0.864), however decreased in case of more frequent teeth brushing ($\beta$=0.737), more frequent periodic check ($\beta$=-0.737), longer duration from the implantation ($\beta$=-0.090). It is very important for the implant patients to be recognized that the lack of care may shorten the life-span of the implant prosthesis. Therefore, efforts of the continuous oral hygiene care such as, periodic recall check, scaling, teeth brushing, the correct using of additional oral hygiene product, and education would be more emphasized.

Implant-assisted removable partial denture using milled bar and Locator in partially edentulous maxilla: A case report (상악 부분 무치악 환자에서 Milled Bar와 Locator를 이용한 임플란트 융합 국소의치수복 증례)

  • Kim, Ji-Hyun;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, Hyeon-Jong;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.137-144
    • /
    • 2020
  • Implant-fixed prostheses and removable partial dentures are widely used as a traditional treatment method for partially edentulous patients who have lost multiple teeth. Recently, there has been increasing interest in implant-assisted removable partial denture (IARPD), which additionally obtains retention and support using a small number of implants. The IARPDs have higher retention, stability, and aesthetics than conventional removable dentures. It also has the effect of reducing the cost as well as the burden of surgery by placing a small number of implants at the edentulous site. In this case, the patient with a partial edentulous state that has multiple numbers of tooth loss in maxilla initially planned to be treated with implant fixed prosthesis. However, the treatment plan was changed to IARPD using Bar and Locator due to several factors. The clinical results were satisfactory on the aspect of esthetic and masticatory function.

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

Eight-year follow-up of two different removable prostheses using six implants in maxillary edentulous patients (상악 완전 무치악 환자에서 6개의 임플란트를 동반한 두가지 가철성 의치 치료의 8년 경과 관찰 증례)

  • Yang, Seung-Won;Kim, Jong-Eun;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.300-304
    • /
    • 2017
  • An implant-supported fixed dental prosthesis (ISFDP) or an implant-supported overdenture (IOD) are good options when treating a completely edentulous jaw opposing natural teeth. However, an ISFDP for a full arch requires sufficient bone quality and quantity, which limits its application. Meanwhile, using an ISFDP as an abutment of a removable partial denture has been considered recently. This clinical report discusses the treatments applied to two patients with edentulous maxillas and opposing natural teeth: one was treated with an IOD and the other was treated with an ISFDP and removable partial denture. Follow-up and management were performed for 8 years.

Use of artificial palate for improving facial support in the fabrication of a maxillary obturator: A case report (상악골 부분 절제술 시행한 환자에서 Artificial Palate로 안모지지를 재현한 폐색장치를 이용한 수복 증례)

  • Yoon, Hee-Kyoung;Hwang, Hee-Seong;Kim, Chul-Hoon;Kim, Jung-Han;Kim, Bok-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.319-324
    • /
    • 2017
  • Patients with maxillectomy defects predisposed to not only difficulty in deglutition, mastication, speech but also psychological depression from impaired facial esthetics that affect life quality. Obturator prostheses play a important role in restoring the lost form, function and the quality of life for patients with maxillectomy defects. This clinical report presents the simplified approach to predict the degree of adequate facial support by Artificial palate which reflected from a maxillary interim obturator during the stabilization period after maxillectomy.

A STUDY OF MARGINAL BONE RESORPTION AROUND IMPLANTS AFTER IMMEDIATE LOADING (Immediate loading하에서 치근형 임프란트 주위 변연골 흡수에 대한 연구)

  • Kim Sung-Hyen;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.376-390
    • /
    • 2001
  • Alveolar bone changes after immediate loading on implants up to one year were observed by means of standard intraoral X-ray measurement which were taken at 3 month intervals. At the same time, bone density changes were observed according to digital subtraction method which is a becoming a more and more promising diagnostic tool for implants. Following results were obtained ; 1. There was no significant difference in the amount of alveolar bone loss implant type, sex and implant diameter, but there was difference according to case selection. In fully bone anchored prostheses cases, bone loss was $1.16{\pm}0.15m$ whereas, in partial edentulous cases, it was $1.84{\pm}0.08mm$. 2. Alveolar bone loss after immediate loading showed a higher degree of bone loss than after submerged loading in the initial three months. But there were no significant difference at the 12th month. 3. According to the one year bone density change observation at the alveolar bone surrounding the implant, significant change was observed vertically, whereas no significant change could observed horizontally. According to the above mentioned results, we can conclude that immediate loading of implants results in a higher degree of alveolar bone loss in one year than submerged loading. But since alveolar bone loss rate decreases to a reasonable rate after the initial 3 months of rapid bone loss, immediate loading of implants seems to be an acceptable treatment modality for patients with good bone conditions. Fully bone anchored cases showed an favorable outcome, but partial edentulous cases showed more bony resorption. So this cases considered in case selections. Bone density changes observation in the study was performed for only one year therefore a more longitudinal observation may be studied.

  • PDF