• Title/Summary/Keyword: Implant prostheses

Search Result 322, Processing Time 0.025 seconds

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

Application and consideration of digital technology for removable complete denture (총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰)

  • Lee, Jung-Jin;Song, Kwang-Yeob;Park, Ju-Mi
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF

An efficient way of communication between dentists and dental technicians to ensure optimum clinical outcome with implant restorations (임플란트 보철물 제작시 치과의사와 기공사가 효과적으로 소통하는 한가지 방법)

  • Kim, Chonghwa
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.66-74
    • /
    • 2020
  • Communication and cooperation between dentists and dental technicians are two essential elements for the fabrication of high quality 'custom' prosthesis. For successful communication and cooperation between the two groups, however, dentists and dental technicians must share common understanding about clinical dentistry. Ironically, it is often noticed that they are not really sharing the same clinical knowledge. Although there is a strong association between 'Emergence Profile' of implant prostheses and periodontal health or esthetics, no definite guideline has ever been provided for ideal emergence profile of implant prosthesis in literature. Problems resulted from inherent differences between implants and natural teeth must be acknowledged and shared between dentists and dental technicians so that they can come up with desirable clinical results with implant prostheses.

Axial displacement in single-tooth implant restoration: Case report (임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고)

  • Jeong, Seung-Hoe;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.126-133
    • /
    • 2021
  • Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

Retrospective study on survival, success rate and complication of implant-supported fixed prosthesis according to the materials in the posterior area (구치부 임플란트 지지 고정성 보철물의 재료에 따른 생존율, 성공률 및 합병증에 대한 후향적 연구)

  • Chae, Hyun-Seok;Wang, Yuan-Kun;Lee, Jung-Jin;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.342-349
    • /
    • 2019
  • Purpose: The purpose of this study was to retrospectively investigate the survival and success rate of implant-supported fixed prosthesis according to the materials in the posterior area. Other purposes were to observe the complications and evaluate the factors affecting failure. Materials and methods: Patients who had been restored implant prosthesis in the posterior area by the same prosthodontist in the department of prosthodontics, dental hospital, Chonbuk National University, in the period from January 2011 to June 2018 were selected for the study. The patient's sex, age, material, location, type of prosthesis and complications were examined using medical records. The KaplanMeier method was used to analyze the survival and success rate. The Log-rank test was conducted to compare the differences between the groups. Cox proportional hazards model was used to assess the association between potential risk factors and success rate. Results: A total of 364 implants were observed in 245 patients, with an average follow-up of 17.1 months. A total of 5 implant prostheses failed and were removed, and the 3 and 5 year cumulative survival rate of all implant prostheses were 97.5 and 91.0, respectively. The 3 and 5 year cumulative success rate of all implant prostheses were 61.1% and 32.9%, respectively. Material, sex, age, location and type of prosthesis did not affect success rate (P>.05). Complications occurred in the order of proximal contact loss (53 cases), retention loss (17 cases), peri-implant mucositis (12 cases), infraocclusion (4 cases) and so on. Conclusion: Considering a high cumulative survival rate of implant-supported fixed prostheses, regardless of the materials, implant restored in posterior area can be considered as a reliable treatment to tooth replacement. However, regular inspections and, if necessary, repairs and adjustments are very important because of the frequent occurrence of complications.

Rehabilitation using short implants in the mandibular fully edentulous patient with severe alveolar bone loss: a case report (치조골 흡수가 심한 하악 완전 무치악 환자에서 짧은 임플란트를 이용한 고정성 보철 수복 증례)

  • Hwang, Hee-Sun;Lee, Ki-Young;Kim, Yu-Lee
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.692-702
    • /
    • 2016
  • A short dental implant is considered as possible solution in difficult clinical situations for the placement of a regular length implant. Using a short implant avoiding more invasive surgical procedures simplifies the treatment plan and shortenes the duration of treatment. In this case, 71-year-old female came up with discomfort from her old mandibular denture. As she had fully edentulous mandible and got a negative feedback from removable denture, implant-supported fixed prosthesis was planned. Six short implants were placed on her mandible with severe alveolar bone loss. After 1 year follow up period, implants were well retained with any other abnormal findings. The patient was satisfied with her prostheses and satisfactory outcomes were attained in terms of both esthetic and functional clinical results.

  • PDF

PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION (하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석)

  • Cho Hye-Won;Kim Nan-Young;Kim Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

Esthetic considerations for anterior implant-supported prostheses: focus on surgical and prosthetic treatment (전치부 임플란트의 연조직 심미성을 달성하기 위한 외과적, 보철적 고려사항)

  • Park, Yeon-Hee;Ahn, Seung-Geun;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.186-198
    • /
    • 2021
  • As the increased certainty of osseointegration, new parameters are now being used to assess implant success. Accordingly, patients' and clinicians' high demands and expectation for esthetics have expanded and implant-supported restorations show better esthetic outcomes. The pre-implant treatment planning process, the implant surgical steps and the post-surgery prosthetic process can affect all esthetic outcomes. Prevention of esthetic implant failures can be achieved by appropriate treatment at each stage, considering the 3 factors of alveolar bone, soft tissue, and implants. It is necessary to achieve the esthetic implant prostheses followings: minimal invasive surgery, bone augmentation, ideal 3-dimensional implant position, peri-implant soft tissue management, and provisional restorations to optimize peri-implant soft tissue architecture.

A prospective multicenter clinical study on the efficiency of detachable ball- and spring-retained implant prosthesis

  • Min-Jung Kim;Won-Tak Cho;Su-Hyun Hwang;Ji-Hyeon Bae;Eun-Bin Bae;June-Sung Shim;Jong-Eun Kim;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.202-213
    • /
    • 2023
  • PURPOSE. This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). MATERIALS AND METHODS. A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. RESULTS. During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. CONCLUSION. Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.