• Title/Summary/Keyword: Implant fracture

Search Result 318, Processing Time 0.025 seconds

Dental alloplastic bone substitutes currently available in Korea

  • Ku, Jeong-Kui;Hong, Inseok;Lee, Bu-Kyu;Yun, Pil-Young;Lee, Jeong Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권2호
    • /
    • pp.51-67
    • /
    • 2019
  • As dental implant surgery and bone grafts were widely operated in Korean dentist, many bone substitutes are commercially available, currently. For commercially used in Korea, all bone substitutes are firstly evaluated by the Ministry of Health and Welfare (MOHW) for safety and efficacy of the product. After being priced, classified, and registration by the Health Insurance Review and Assessment Service (HIRA), the post-application management is obligatory for the manufacturer (or representative importer) to receive a certificate of Good Manufacturing Practice by Ministry of Food and Drug Safety. Currently, bone substitutes are broadly classified into C group (bone union and fracture fixation), T group (human tissue), L group (general and dental material) and non-insurance material group in MOHW notification No. 2018-248. Among them, bone substitutes classified as dental materials (L7) are divided as xenograft and alloplastic bone graft. The purpose of this paper is to analyze alloplastic bone substitutes of 37 products in MOHW notification No. 2018-248 and to evaluate the reference level based on the ISI Web of Knowledge, PubMed, EMBASE (1980-2019), Cochrane Database, and Google Scholar using the criteria of registered or trademarked product name.

외상 후 발생한 횡문근육종 (Rhabdomyosarcoma Following Traumatic Injury)

  • 권대규;박성준;윤영훈;이동주
    • 대한정형외과학회지
    • /
    • 제55권3호
    • /
    • pp.271-275
    • /
    • 2020
  • 외상은 횡문근육종을 포함한 일부 육종의 발생에 영향을 미친다고 알려져 있고 수술 후 반흔이나 화상 흉터, 골절 부위, 금속 내고정물 주위에서 수년 간의 잠복기를 거쳐 육종을 일으킨 사례들이 드물게 보고되고 있다. 저자들은 컨베이어 벨트에 의해 압궤상을 입은 전완부에 11년 뒤 발생한 횡문근육종의 사례를 경험하였다. 조직 손상으로 인한 염증 반응, 많은 방사선 촬영에 대한 노출, 금속 내고정물, 감각 및 운동 마비로 인한 무의식적이고 반복적인 손상이 육종의 발생에 영향을 미쳤으리라고 생각된다. 이러한 광범위한 조직 손상 후에는 육종 발생 가능성을 염두에 두고 육종 유발 요인에 대한 노출에 주의를 기울여야 하겠다.

Complications reported with the use of orthodontic miniscrews: A systematic review

  • Giudice, Antonino Lo;Rustico, Lorenzo;Longo, Miriam;Oteri, Giacomo;Papadopoulos, Moschos A.;Nucera, Riccardo
    • 대한치과교정학회지
    • /
    • 제51권3호
    • /
    • pp.199-216
    • /
    • 2021
  • Objective: The aim of this systematic review was to evaluate the complications and side effects associated with the clinical use of orthodontic miniscrews by systematically reviewing the best available evidence. Methods: A survey of articles published up to March 2020 investigating the complications associated with miniscrew insertion, in both the maxilla and mandible, was performed using 7 electronic databases. Clinical studies, case reports, and case series reporting complications associated with the use of orthodontic miniscrew implants were included. Two authors independently performed study selection, data extraction, and risk-of-bias assessment. Results: The database survey yielded 24 articles. The risk-of-bias assessment revealed low methodological quality for the included studies. The most frequent adverse event reported was root injury with an associated periradicular lesion, vitality loss, pink discoloration of the tooth, and transitory loss of pulp sensitivity. Chronic inflammation of the soft tissue surrounding the miniscrew with mucosal overgrowth was also reported. The other adverse events reported were lesion of the buccal mucosa at the insertion site, soft-tissue necrosis, and perforation of the floor of the nasal cavity and maxillary sinus. Adverse events were also reported after miniscrew removal and included secondary bleeding, miniscrew fracture, scars, and exostosis. Conclusions: These findings highlight the need for clinicians to preliminarily assess generic and specific insertion site complications and side effects.

하이드록시아파타이트/포스터라이트 복합분말의 분사코팅에 의한 3Y-TZP 기판의 표면개질과 생체활성 증진 (Surface Modification and Bioactivity Improvement of 3Y-TZP Substrate by Spray Coating of Hydroxyapatite/Fosterite Composite Powder)

  • 윤유현;이종국
    • 한국재료학회지
    • /
    • 제33권8호
    • /
    • pp.337-343
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals) ceramics have excellent mechanical properties including high fracture toughness, good abrasion resistance as well as chemical and biological stability. As a result, they are widely used in mechanical and medical components such as bearings, grinding balls, and hip implants. In addition, they provide excellent light transmittance, biocompatibility, and can match tooth color when used as a dental implant. Recently, given the materials' resemblance to human teeth, these ceramics have emerged as an alternative to titanium implants. Since the introduction of CAD/CAM in the manufacture of ceramic implants, they've been increasingly used for prosthetic restoration where aesthetics and strength are required. In this study, to improve the surface roughness of zirconia implants, we modified the 3Y-TZP surface with a biocomposite of hydroxyapatite and forsterite using room temperature spray coating methods, and investigated the mixed effect of the two powders on the evolution of surface microstructure, i.e., coating thickness and roughness, and biological interaction during the in vitro test in SBF solution. We compared improvement in bioactivity by observing dissolution and re-precipitation on the specimen surface. From the results of in vitro testing in SBF solution, we confirmed improvement in the bioactivity of the 3Y-TZP substrate after surface modification with a biocomposite of hydroxyapatite and forsterite. Surface dissolution of the coating layer and the precipitation of new hydroxyapatite particles was observed on the modified surface, indicating the improvement in bioactivity of the zirconia substrate.

견관절 인공관절 재치환술의 원인과 치료 (Etiology and Treatment of Revision Shoulder Arthroplasty)

  • 김영규;정규학
    • 대한정형외과학회지
    • /
    • 제54권2호
    • /
    • pp.100-109
    • /
    • 2019
  • 견관절 인공관절 성형술의 빈도가 빠른 속도로 증가함에 따라 일차적 인공관절 성형술과 관련된 다양한 형태의 합병증이 발생하고, 이로 인해 재치환술 역시 증가하고 있는 추세이다. 견관절 인공관절 재치환술은 여러 원인에 의해 발생되는 것으로 알려져 있는데 일차적 인공관절 성형술 후 나타난 회전근 개 파열, 관절와 상완 관절의 불안정성, 관절와 또는 상완골 치완물의 해리, 인공 치환물의 실패, 치환물 주위 골절, 감염 등이 있다. 재치환술은 술기적으로 어려운 과제이다. 실패한 견관절 인공관절 성형술은 해결할 수 있는 외과적 선택이 많지 않다. 특히 관절와 골 결손 또는 봉합 불가능한 회전근 개 파열이 있는 경우에는 더욱 어렵다. 또한 재치환술의 결과는 일차적 성형술의 결과에 비해 항상 좋지 않다. 결국 외과의는 수술을 결정하기 전에 일차적 인공관절 성형술이 실패한 원인을 잘 파악하여야 한다. 따라서 본 논문에서는 실패한 일차적 인공관절 성형술 후 재치환술의 적응증에 대해 살펴보고 실패의 원인에 따른 재치환술의 술기에 대해 논의하고자 한다.

Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly

  • Mathias van den Broek;Kris Govaers
    • Hip & pelvis
    • /
    • 제35권1호
    • /
    • pp.54-61
    • /
    • 2023
  • Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.

Prosthetic resurfacing of engaging posterior capitellar defects in recurrent posterolateral rotatory instability of the elbow

  • Dani Rotman;Jorge Rojas Lievano;Shawn W. O'Driscoll
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.287-295
    • /
    • 2023
  • Background: Posterolateral rotatory instability (PLRI) is a common mechanism of recurrent elbow instability. While the essential lesion is a deficiency in the lateral ulnar collateral ligament (LUCL), there are often associated concomitant bony lesions, such as an Osborne-Cotterill lesions (posterior capitellar fractures) and marginal radial head fractures, that compromise stability. Currently, there is no standard treatment for posterior capitellar deficiency associated with recurrent PLRI. Methods: We conducted a retrospective review of five patients with recurrent PLRI of the elbow associated with a posterior capitellar impaction fracture engaging with the radial head during normal range of motion. The patients were treated surgically with LUCL reconstruction or repair and off-label reconstruction of the capitellar joint surface using a small metal prosthesis designed for metatarsal head resurfacing (HemiCAP toe classic). Results: Five patients (three adolescent males, two adult females) were treated between 2007 and 2018. At a median follow-up of 5 years, all patients had complete relief of their symptomatic instability. No patients had pain at rest, but two patients had mild pain (visual analog scale 1-3) during physical activity. Three patients rated their elbow as normal, one as almost normal, and one as greatly improved. On short-term radiographic follow-up there were no signs of implant loosening. None of the patients needed reoperation. Conclusions: Recurrent PLRI of the elbow associated with an engaging posterior capitellar lesion can be treated successfully by LUCL reconstruction and repair and filling of the capitellar defect with a metal prosthesis. This treatment option has excellent clinical results in the short-medium term. Level of evidence: IV.

Three-dimensional computer navigation in the reconstruction of complex unilateral orbital fractures: evaluation and review of applications

  • Parampreet Singh Saini;Rajesh Kumar;Manu Saini;Tarush Gupta;Sunil Gaba;Ramesh Kumar Sharma
    • 대한두개안면성형외과학회지
    • /
    • 제25권4호
    • /
    • pp.161-170
    • /
    • 2024
  • Background: The eyes are the central aesthetic unit of the face. Maxillofacial trauma can alter facial proportions and affect visual function with varying degrees of severity. Conventional approaches to reconstruction have numerous limitations, making the process challenging. The primary objective of this study was to evaluate the application of three-dimensional (3D) navigation in complex unilateral orbital reconstruction. Methods: A prospective cohort study was conducted over 19 months (January 2020 to July 2021), with consecutive enrollment of 12 patients who met the inclusion criteria. Each patient was followed for a minimum period of 6 months. The principal investigator carried out a comparative analysis of several factors, including fracture morphology, orbital volume, globe projection, diplopia, facial morphic changes, lid retraction, and infraorbital nerve hypoesthesia. Results: Nine patients had impure orbital fractures, while the remainder had pure fractures. The median orbital volume on the normal side (30.12 cm3; interquartile range [IQR], 28.45-30.64) was comparable to that of the reconstructed orbit (29.67 cm3; IQR, 27.92-31.52). Diplopia improved significantly (T(10)= 2.667, p= 0.02), although there was no statistically significant improvement in globe projection. Gross symmetry of facial landmarks was achieved, with comparable facial width-to-height ratio and palpebral fissure lengths. Two patients reported infraorbital hypoesthesia at presentation, which persisted at the 6-month follow-up. Additionally, five patients developed lower lid retraction (1-2 mm), and one experienced implant impingement at the infraorbital border. Conclusion: Our study provides level II evidence supporting the use of 3D navigation to improve surgical outcomes in complex orbital reconstruction.

대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구 (A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure-)

  • 전춘배;서재성;안면환;안종철;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제7권1호
    • /
    • pp.81-93
    • /
    • 1990
  • 1983년 5월부터 1989년 9월까지 본 영남의료원 정형외과에 대퇴골 간부골절시 사용한 금속 내 고정물의 금속 부전으로 입원한 경우 중 부전된 금속의 표면관찰이 가능한 8례에 대한 임상적 고찰 및 부전된 금속 파손 표면의 관찰을 통해 확인한 파손 원인을 요약하면 다음과 같다. 1. 금속 부전이 발생 내고정물의 종류는 압박금속판 5례, Jewett nail 1례, Rowe plate screw 1례, interlocking nail 1례였다. 2. 금속 부전의 임상적 추정에 의한 원인으로는 반대편 피질골 결손 5례, 부적절한 위치선정 1례 및 부적절한 금속선택 1례였다. 3. 금속 내고정후 금속 부전이 되기까지의 기간을 보면, 4개월이 1례, 6개월에서 12개월 사이가 6례, 3년이 1례였다. 4. 부전된 내고정물의 파손면 관찰을 통해 확인한 금속부전의 원인을 보면, 첫째, impact failure 1례 둘째, fatigue failure 6례 machining mark가 있어 이것이 stress riser로서 역할을 한 것으로 보이는 경우가 4례였으며, 이의 형태는 low consistent cyclic fatigue failure와 irregular cyclic fatigue failure의 형태를 관찰할 수 있었다. 셋째, Stress corrosion crack 1례를 관찰할 수 있었다. 5. 316L Stainless Steel은 내부식성이 좋은 금속이지만 fretting에 의해 특유의 부동태 피막이 손상되면 pitting corrosion을 일으키며 경우에 따라서는 파손의 기점으로 작용되어 failure의 주요 원인이 되기도 한다. 6. screw hole의 가공시 기계에 의한 손상 및 기구(implant) 제조 과정중 손상이 plate의 failure를 유발하는 중요한 원인이 될 수도 있다. 기계에 의한 손상은 응력을 집중시키므로 plate가 파손되기 쉽게 한다. 이상의 결과 임상적 추정에 의한 원인 이외에도 부전된 금속파손면 관찰을 통해 중요한 다른 원인을 찾을 수 있었으므로, 금속부전의 예방을 위해 앞으로 이 방향으로의 계속적인 연구가 필요할 것으로 사료된다.

  • PDF

CAD/CAM을 이용한 다운 증후군 환자의 구강 재건 (APPLICATION OF CAD/CAM FOR ORAL REHABILITATION IN A PATIENT WITH DOWN SYNDROME)

  • 정현진;심준성;최병재;이제호
    • 대한장애인치과학회지
    • /
    • 제13권2호
    • /
    • pp.95-98
    • /
    • 2017
  • 본 증례는 다운 증후군이 있는 환자의 구강 재건 시 CAD/CAM 시스템 사용의 이점을 모색해보았다. 다운 증후군 환자들의 경우, 보철물 파절의 위험성이 크며 불가피하게 보철물을 재제작할 경우, CAD/CAM 시스템의 기존 데이터를 이용하여 최소한의 기공 과정만 진행하여 보철물을 빠른 시일 내에 재제작할 수 있다. 결과적으로 이는 심미적 및 기능적 개선을 통해 삶의 질을 높일 수 있는 보철물 제작 시 환자의 불편감과 치과의사의 노력을 최소화하는 방법이다.