• Title/Summary/Keyword: Implant exposure

Search Result 179, Processing Time 0.026 seconds

Preservation of Exposed Breast Implant for Immediate Breast Reconstruction (보형물을 이용한 즉시 유방재건술에서 노출된 보형물의 보존)

  • Lee, Taik-Jong;Oh, Tae-Suk
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.26-30
    • /
    • 2010
  • Purpose: Common complications of immediate breast reconstruction with implant are capsular contracture, malposition of implant, hematoma and seroma. Especially, the most severe complication is implant exposure caused by inflammation or necrosis of skin flap margin of mastectomy site. This article reports the experience of cases of salvage in such an exposure of implant. Methods: From July, 2002 to Feb., 2009, sixty-five patients who underwent immediate breast reconstruction with implant were retrospectively analyzed. Exposure of implant was happened in 5 of 65 patients and they were treated at out patient district. Two of five patients were reconstructed with saline implnt and all of them underwent the enveloping of the implant with AlloDerm$^{(R)}$ and Serratus muscle flap. Remaning three patients were reconstructed with silicone implant and all of them underwent the enveloping of the implant with AlloDerm$^{(R)}$. Results: In the group of patients who underwent reconstruction with saline implant, implant exposure was found in one patient due to partial necrosis of the margin of skin flap and debridement and primary repair were done. In the other one patient, dressing with antibiotic ointment were done. And debridement and primary repair were proceeded. In the group of patients who underwent reconstruction with silicone implant, implant exposure was found in one patient. After removal of the implant, tissue expansion was done and a new silicone implant was inserted. Implant exposure were found in the other two patients, antibiotics ointment application and primarily repaired. Conclusion: It was the common knowledge that the exposed implant should be removed. But salvage of the exposed implants may be possible with proper treatment. Four of five patients (80%) with exposed breast implant were salvaged with conservative management.

Prevalence of dental implant positioning errors: A cross-sectional study

  • Gabriel, Rizzo;Mayara Colpo, Prado;Lilian, Rigo
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.343-350
    • /
    • 2022
  • Purpose: This study evaluated the prevalence of dental implant positioning errors and the most frequently affected oral regions. Materials and Methods: A sample was obtained of CBCT images of 590 dental implants from 230 individuals who underwent diagnosis at a radiology center using cone-beam computed tomography from 2017 to 2020. The following variables were considered: thread exposure, violation of the minimum distance between 2 adjacent implants and between the implant and tooth, and implant contact with anatomical structures. Descriptive data analysis and the Pearson chi-square test(P<0.05) were performed to compare findings according to mouth regions. Results: Most (74.4%) of the 590 implants were poorly positioned, with the posterior region of the maxilla being the region most frequently affected by errors. Among the variables analyzed, the most prevalent was thread exposure (54.7%), followed by implant contact with anatomical structures, violation of the recommended distance between 2 implants and violation of the recommended distance between the implant and teeth. Thread exposure was significantly associated with the anterior region of the mandible (P<0.05). The anterior region of the maxilla was associated with violation of the recommended tooth-implant distance (P<0.05) and the recommended distance between 2 adjacent implants(P<0.05). Implant contact with anatomical structures was significantly more likely to occur in the posterior region of the maxilla (P<0.05). Conclusion: Many implants were poorly positioned in the posterior region of the maxilla. Thread exposure was particularly frequent and was significantly associated with the anterior region of the mandible.

Retrospective Study of Success Rate of the $XiVE^{(R)}$ Implant;Early evaluation of clinical performance (($XiVE^{(R)}$ 임프란트의 성공률에 관한 후향적 연구;임상성적에 관한 조기평가)

  • Park, Jin-Woo
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.65-76
    • /
    • 2005
  • This retrospective study evaluates the clinical performance of the recently introduced $XiVE^{(R)}$ implant(Dentsply-Friadent) with a new macro-design to improve primary stability. A total of 208 $XiVE^{(R)}$ implants (101 in the maxilla and 107 in the mandible) were placed in 71 patients. The average age of the patients was 49 years. Of the 208 implants, 190 (91.3%) were posterior implants and 82 (39.4%) were placed in compromised sites (grafted sites). Clinical and radiographic evaluation were made at second stage surgery for exposure and after functional loading. 192 implants in 64 patients were evaluated at exposure and 146 implants in 50 patients were loaded (average 170 days-loading) and evaluated after functional loading. Of 192 implants available for evaluation before loading, 3 implants failed (early failure) ; 1 before exposure, 1 at exposure and 1 during prosthetic procedure. 2 implants were in the maxilla and 1 was in the mandible. The success rate before loading was 98.4%. After functional loading, no implant failure was occurred in 146 implants evaluated during this period (100% interval success rate). This preliminary data with a new implant showed excellent success rate although the majority of implants evaluated in this study were placed in the posterior region of the jaw and compromised sites.

Effect of the early exposure of cover screws on the survival rate of implants (덮개 나사 조기 노출이 임플란트의 생존율에 미치는 영향)

  • Kim, Yong-Gun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.879-889
    • /
    • 2006
  • The early exposure of cover screws is a common complication of 2-stage implant technique. The exposure of cover screws between stage I and IT surgery may cause inflammation in the soft tissues surrounding the implants, and lead to peri-implantitis or marginal bone loss. The purpose of this study was to evaluate the effect of the early exposure of cover screws on implants placed using 2-stage technique. Two hundred and nineteen implants in 77 patients were examined for cumulative survival rate, radiographic marginal bone level change, cause and frequency of the early exposure. The results were as follows: 1. Twenty-five implants showed early exposure of cover screws with a frequency of 11.4%. 2. Cumulative survival rate of the implants with early cover screw exposure was 88.0%, and that of the implants without cover screw exposure was 96,9%. 3. At the time of stage IT surgery and 1 year after loading, the marginal bone loss was greater around the implants with early exposure of cover screws than around the implants without cover screw exposure(p <0.05), 4, There was no statistically significant difference in the frequency of the early exposure according to the implant diameter, gender, and smoking(p >0,05).

Soft-tissue management for primary closure in immediate implant placement (즉시 식립 임플란트의 일차폐쇄를 위한 연조직 처치)

  • Kim, Kang-Woo;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.253-262
    • /
    • 2008
  • Background: Incomplete flap coverage or early exposure over implants and/or barrier membranes have a negative effect on bone regeneration. In cases of using regenerative techniques, complete soft tissue coverage of the implant area is necessary to promote adequate conditions for guided bone regeneration. Primary socket closure may be difficult, when periosteal releasing incision is only used, due to the opening left by extracted tooth. Therefore, Soft tissue grafting techniques are used to achieve primary soft tissue closure. Materials and Methods: Soft tissue grafting techniques, with or without barrier membranes, were performed for primary closure in four cases of immediate placements. Three different methods were used (CTG, VIP-CT, Palatal advanced flap). Clinical results of the grafting were evaluated. Result: One case showed early exposure of cover-screw and, no other complications were noted. In the others, Primary closure was achieved by soft tissue grafting techniques. One of the cases, Graft showed partial necrosis, but there were no exposure over implants and/or barrier membranes. Conclusion: The use of grafting techniques, in immediate implant placement, can predictably obtain primary closure of extraction sockets, thereby providing predictable bone formation and improved implant results.

IN VITRO COMPARATIVE STUDY BETWEEN ISQ AND $PERIOTEST^{(R)}$ VALUES ON THE IMPLANT STABILITY MEASUREMENTS ACCORDING TO THE INCREASED EFFECTIVE IMPLANT LENGTH

  • Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.625-632
    • /
    • 2001
  • Statement of Problem. Objective and quantitative measurement of implant stability is very important from implant installation to long-lasting maintenance period thereafter. Purpose of study. This study was to evaluate and compare two ISQ and PTVs on the implant stability measurements according to the increased effective implant length. Materials and methods. Twenty self-tapping fixtures were installed in the bovine scapula and in 10 of those for group I, ISQ and PTVs were obtained in the vertical/horizontal directions according to the increased effective implant length using $Osstell^{TM}$ and $Periotest^{(R)}$. After stability measurement, removal torques were measured between the after installation and after thread exposure group. Results. ISQ and PTVs showed decreased and increased values according to the increased abutment length. Apart from PTVs, ISQ values were shown higher in horizontal direction to the long axis of bone in both the after installation and the after thread exposure groups. Removal torque values were shown higher in after installation group. Conclusion. From the results of this study, implant stability measurement using resonance frequency analysis was more sensitive and discriminative than PTVs measurement.

  • PDF

ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS (치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구)

  • Jung Young-Chul;Han Chong-Hyun;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

Analysis on cause of failure of guided bone regeneration during implant placement : A retrospective study (임플란트 시술 시 GBR의 실패 원인분석에 관한 후향적 연구)

  • Ko, Sun-Young;Oh, Jun-Ho;Lee, Seung-Jae;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.535-542
    • /
    • 2008
  • Purpose: The aim of this retrospective study is to evaluate survival rate of implant and bone formation, to analyze failure contribution factor. Material and Methods: A total of 52 consecutive patients(35 male, 17 female, mean age 49 years) with 104 osseous defects were treated during the period from October 2004 to June 2007 with a simultaneous or staged GBR approach using non-resorbable or resorbable membranes combined with autogenous bone grafts or xenograft(Bio-Oss, Bio-cera, BBP). Result: A total of 32(30,8%) of 104 GBR-treated sites failed the bone formation and a total of 5(5.6%) of 89 implants were removed. Early exposure of the membrane has significantly affected bone formation(p<0.05). Non-resorbable membrane showed more exposure of the membrane and low success rate of bone formation than resorbable membrane(p<0.05). There were no difference between success rate of bone formation and using autogenous bone or graft materials. There were no statistically significant difference between success rate of bone formation and smoking or using PRP. Mandible showed more success rate of bone formation than maxilla(p<0.05). Conclusion: Early exposure of the membrane, membrane type and maxilla/mandible type have influence on success rate of bone formation during GBR.

Clinical and histopathological study on the effect of Nonresorbable membrane with Demineralized freeze dried bone graft for Guided Bone Regeneration in Implant Dehiscence Defects (매식체 주위 열개형 골결손부에서 차단막과 골 이식술의 사용이 골 형성에 미치는 영향에 대한 임상 및 조직병리학적 연구)

  • Kwon, Chil-Sung;Hong, Ki-Seok;Lim, Sung-Bin;Chung, Chin-Hyung;Lee, Chong-Heon
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.687-702
    • /
    • 2005
  • The purpose of this study is to examine the effect of non-resorbable membrane such as e-PTFE which was used with DFDB in bone regeneration on dehiscence defect in peri-implant area. Amomg the patients, who have recieved an implant surgery at the department of Periodontics in Dan Kook University Dental Hospital, 12 patients showed implant exposure due to the dehiscence defect and 15 implants of these 22 patients were the target of the treatment. Periodontists randomly applied $Gore-Tex^{(R)}$ to the patients and treated them with antibiotics for five days both preoperatively and postoperatively. Reentry period was 26 weeks on average in maxilla and 14 weeks on average in mandible. The results were as follows : 1. Dehiscence bone defect frequently appeared in premolar in mandible and anterior teeth in maxilla respectively. 2. Among 15 cases, 1 membrane exposure was observed and in this case, regenerated area was decreased. 3. In non-resorbable membrane, bone surface area $9.25{\pm}4.84$ preoperatively and significantly increased to $11.48{\pm}7.52$ postoperatively(0.05). 4. The increase of bone surface area in non-resorbable membrane was $2.23{\pm}3.38$. 5. As a result of histopathological finding, DFDB surrounded by new bone formation and lamellate bone, resorption of DFDB and bone mineralization was found. Also, fibrosis of connective tissue beneath the membrane was found. This study shows that the surgical method using DFDB and non-resorbable membrane on dehiscence defect in peri-implant area is effective in bone regeneration.

A COMPARATIVE ANALYSIS WITH RESONANCE FREQUENCY ACCORDING TO VARIOUS SIMULATED BONE DEFECTS (다양한 가상 골 결함에 따른 공진 주파수의 비교 분석)

  • Kim Sang-Mi;Park Chan-Jin;Yi Yang-Jin;Chang Beom-Seok;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.487-497
    • /
    • 2005
  • Purpose: Resonance frequency analysis (RFA) , a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitro study evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined self-tapping implant future were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc $Sch\`{e}ffe'$ test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-$360^{\circ}$ group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion : Although the simulated defect type was different from each other, the ISQ value was similar among groups.