• 제목/요약/키워드: Implant Design

검색결과 475건 처리시간 0.024초

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례 (Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report)

  • 이승훈;김성균;허성주;곽재영;박지만
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.367-378
    • /
    • 2023
  • 최근 CAD-CAM (computer-aided design-computer-aided manufacturing) 기술 및 3D 프린팅 기술의 발전과 함께 다양한 디지털 기법들의 도입으로 top-down 방식의 최종 보철 수복의 정확성과 효율성이 증대되고 있다. 본 증례는 전후 엇갈린 교합을 가진 환자에서 총 9개의 상하악 구치부 임플란트 식립을 통해 안정적인 교합 지지를 얻으면서 잔존 치조골의 고도 흡수 경향을 보인 상악 전치부 무치악 부위는 케네디 4급 임플란트 보조 국소의치로 수복함으로써 연조직의 심미성을 회복하였다. 전산화단층촬영 가이드 수술로 계획된 위치에 임플란트를 식립하고, 이중 스캔 기법으로 임시 수복 단계에서 안정화된 교합을 최종 보철물에 반영하며, 코핑과 프레임워크를 금속 3D 프린팅으로 제작하여 효율적이며 예측 가능한 top-down 방식의 전악 구강 수복을 달성하였기에 이를 보고하고자 한다.

CAD-CAM Konus type 부착장치를 이용한 하악 임플란트 피개의치 보철수복 증례 (Mandibular implant-supported overdenture using CAD-CAM Konus type attachment: A case report)

  • 박종희;김인주;김경아;송광엽;서재민
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.259-266
    • /
    • 2016
  • 하악 완전 무치악 환자의 보철수복에 있어 임플란트 식립 후 피개의치 제작은 첫 번째 치료 옵션으로 고려된다. 코너스 타입 부착장치를 이용한 피개의치는 견고한 지지를 제공하고 cross arch stabilization을 이루도록 하여 교합압을 균일하게 분산시키며, 의치에 의한 이차 고정으로 장기간의 안정성을 제공한다. 최근 소개된 팔라듐-은(Pd-Ag) 합금(Innovium)은 팔라듐, 은, 금 등의 귀금속 함량이 72% 이상인 CAD-CAM 시스템 전용 귀금속 합금으로 코너스 타입 부착장치를 제작하는데 적합한 물성을 가지고 있다. 본 증례에서는 완전 무치악 환자에서 상악에는 통상적인 총의치, 하악에는 임플란트를 4개 식립한 후에 코너스 타입 부착장치 피개의치 수복을 하였다. CAD-CAM 시스템을 이용하여 팔라듐-은 합금(Innovium)으로 제작된 코너스 타입 부착장치를 장착하였으며 이를 통해 의치의 유지와 안정을 향상시켰으며 만족할 만한 결과를 얻었기에 보고하고자 한다.

개선된 드릴 디자인을 적용한 간소화된 드릴링 과정에 관한 연구 (A study on simplified procedure of enhanced designed implant drill)

  • 윤지훈;전계록;윤미정;허중보;정창모
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.368-376
    • /
    • 2015
  • Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.

잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique (Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique)

  • 홍영택;곽재영;김성균;허성주
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.63-70
    • /
    • 2021
  • CAD-CAM 기술의 사용은 다양한 부분에서 치료의 결과를 향상시킨다. 본 증례는 법랑질형 성부전증 환자를 디지털 기술을 이용해 치료한 전악구강회복 증례이다. 임상적 검사 결과 occlusal stop의 부재로 저작기능의 저하와 치아 상실, 왜소치로 인한 치간사이 공간, 불충분한 수직피개 등의 문제점이 파악되었다. 하악의 치아 상실 부위를 수복키 위해 CAD-CAM 수술 스텐트를 이용한 임플란트 식립이 진행되었고 추가적으로 부족한 골량을 보강하기 위해 골유도재생술이 동반되었다. 상하악 자연치는 모두 전장관수복을 통해 새로운 교합평면 설정 및 안정적인 수직교합관계를 형성하였다. ARCUS digma 장비를 통한 잠정수복물 평가 후 디지털 기술을 이용하여 잠정수복물 상태의 수복물을 더블스캔을 통한 복제를 하여 최종수복물을 제작, 환자에게 수복하여 전악수복을 완성하였다. 이를 통해 치료의 효율성과 예지성 있는 결과, 환자의 적응기간 감소와 기능적, 심미적으로 높은 만족도 등을 이루어냈다.

Influence of lateralized versus medialized reverse shoulder arthroplasty design on external and internal rotation: a systematic review and meta-analysis

  • Kevin A. Hao;Robert J. Cueto;Christel Gharby;David Freeman;Joseph J. King;Thomas W. Wright;Diana Almader-Douglas;Bradley S. Schoch;Jean-David Werthel
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.59-71
    • /
    • 2024
  • Background: Restoration of external (ER) and internal rotation (IR) after Grammont-style reverse shoulder arthroplasty (RSA) is often unreliable. The purpose of this systematic review was to evaluate the influence of RSA medio-lateral offset and subscapularis repair on axial rotation after RSA. Methods: We conducted a systematic review of studies evaluating axial rotation (ER, IR, or both) after RSA with a defined implant design. Medio-lateral implant classification was adopted from Werthel et al. Meta-analysis was conducted using a random-effects model. Results: Thirty-two studies reporting 2,233 RSAs were included (mean patient age, 72.5 years; follow-up, 43 months; 64% female). The subscapularis was repaired in 91% (n=2,032) of shoulders and did not differ based on global implant lateralization (91% for both, P=0.602). On meta-analysis, globally lateralized implants achieved greater postoperative ER (40° [36°-44°] vs. 27° [22°-32°], P<0.001) and postoperative improvement in ER (20° [15°-26°] vs. 10° [5°-15°], P<0.001). Lateralized implants with subscapularis repair or medialized implants without subscapularis repair had significantly greater postoperative ER and postoperative improvement in ER compared to globally medialized implants with subscapularis repair (P<0.001 for both). Mean postoperative IR was reported in 56% (n=18) of studies and achieved the minimum necessary IR in 51% of lateralized (n=325, 5 cohorts) versus 36% (n=177, 5 cohorts) of medialized implants. Conclusions: Lateralized RSA produces superior axial rotation compared to medialized RSA. Lateralized RSA with subscapularis repair and medialized RSA without subscapularis repair provide greater axial rotation compared to medialized RSA with subscapularis repair. Level of evidence: 2A.

EFFECT OF THE SURFACE MODIFICATIONS AND THE USE OF WASHER ON THE REVERSE TORQUE OF THE IMPLANT PROSTHETIC GOLD RETAINING SCREW

  • Lee, Jae-Hyuck;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.246-261
    • /
    • 2002
  • The screw loosening is one of the complications that happen frequently in dental implant prostheses. The purpose of this study was to evaluate the changes of reverse/loosening (opening) torque of the screw according to the surface modifications by sandblasting and 24K gold electroplating as well as to determine the possibility of the clinical use of a washer in dental implant. The reverse torque of 4 experimental conditions(control, sandblasted, use of washers, electroplasted) was measured by digital torque gauge (Model MGT50Z, Mark-10 Corp., 458 West John Street Hicksville, NY 11801 USA). Electronic torque controller (Nobel Biocare DEA 020) was used in fastening the gold screws into abutment replicas. Mixed Linear Model Analysis method was used for statistical analysis. To examine the changes of screw thread surface, microphotographs were taken by Olympus PME-3 metallurgic microscope (Olympus Optical Co. Ltd., Tokyo, Japan). Within the limitations of this study, the following results were drawn: 1. The surface modifications of the gold screws and the use of a washer have significantly affected the reverse torque value compared to the control group (P<0.01). 2. Sandblasting and electroplating treatments demonstrated significantly higher reverse torque value than that of control group. 3. The use of a washer may be one of the useful clinical methods that prevent the screw loosening. However, further studies are necessary for the material selection and design of the washer.

단일구조 수복용 지르코니아와 Dental CAD/CAM System을 이용한 전악 임플란트 고정성 보철 수복 증례 (Full mouth rehabilitation of a patient using monolithic zirconia and dental CAD/CAM system: a case report)

  • 이상훈;윤형인;여인성;한중석;김성훈
    • 구강회복응용과학지
    • /
    • 제34권3호
    • /
    • pp.196-207
    • /
    • 2018
  • 임플란트의 장기적인 안정을 위해서는 이상적인 위치와 각도로 임플란트를 식립하는 것이 중요하며, 이를 위해서는 정확한 계획에 따른 정확한 수술과 보철이 중요하다. 본 증례에서는 치조골 흡수가 심하게 진행된 환자에서 CT data 및 진단왁스업을 스캔한 data를 이용하여 CT guided surgery를 시행하고, 단일구조 수복용 지르코니아와 CAD/CAM technique을 이용하여 전악 임플란트 고정성 보철로 수복하여 기능 및 심미적으로 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

트렌치 게이트 IGBT 에서의 공정 및 설계 파라미터에 따른 항복 전압 특성에 관한 연구 (A Study on the Breakdown Voltage Characteristics with Process and Design Parameters in Trench Gate IGBT)

  • 신호현;이한신;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.403-409
    • /
    • 2007
  • In this paper, effects of the trench angle($\theta$) on the breakdown voltage according to the process parameters of p-base region and doping concentrations of n-drift region in a Trench Gate IGBT (TIGBT) device were analyzed by computer simulation. Processes parameters used by variables are diffusion temperature, implant dose of p-base region and doping concentration of n-drift region, and aspects of breakdown voltage change with change of each parameter were examined. As diffusion temperature of the p-base region increases, depth of the p-base region increases and effect of the diffusion temperature on the breakdown voltage is very low in the case of small trench angle($45\;^{\circ}$) but that is increases 134.8 % in the case of high trench angle($90\;^{\circ}$). Moreover, as implant dose of the p-base region increases, doping concentration of the p-base region increases and effect of the implant dose on the breakdown voltage is very low in the case of small trench angle($45\;^{\circ}$) but that is increases 232.1 % in the case of high trench angle($90\;^{\circ}$). These phenomenons is why electric field concentrated in the trench is distributed to the p-base region as the diffusion temperature and implant dose of the p-base increase. However, effect of the doping concentration variation in the n-drift region on the breakdown voltage varies just 9.3 % as trench angle increases from $45\;^{\circ}$ to $90\;^{\circ}$. This is why magnitude of electric field concentrated in the trench changes, but direction of that doesn't change. In this paper, respective reasons were analyzed through the electric field concentration analysis by computer simulation.