• Title/Summary/Keyword: Impedance Ratio

Search Result 573, Processing Time 0.027 seconds

A Study on Deicing Current Estimation Technique and Configuration Process for Deicing System in the Conventional Line (기존선 해빙시스템을 위한 해빙전류 예측기법 및 구성 절차에 관한 연구)

  • Kwon, Sam-Young;Park, Young;Jung, Ho-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.2 s.33
    • /
    • pp.237-243
    • /
    • 2006
  • Deicing system is to melt frost or ice freezed in catenary line when the temperature is lower than $0^{\circ}C$ in winter. The principle of deicing system is to melt frost or ice by Joule heat of catenary impedance. The performance of deicing is dependant of deicing current determined by the length of deicing section, deicing impedance and current division ratio of catenary line and messenger line. So, we present technique for estimating deicing current and process for determination of deicing section in the conventional line. Deicing impedance is estimated using Carson-Pollaczek equation, and current division ratio of catenary line and messenger line is estimated using voltage drop, and deicing current is estimated using power system data of deicing system. For the determination of the final deicing section, we verified estimated value comparing with experiment value of deicing impedance and current division ratio of catenary line and messenger line using low voltage experiment. Finally, we verified the validity of estimation technique and process using a simulated test data of real deicing system operation in the Chungju Substation, Chungbuk line.

Development of Frequency Dependent Type Apex-Locator Improvementation by Auto-calibration Using Impedance Difference (주파수 의존형 전자근관장측정기 개발 및 임피던스차를 이용한 자동보정에 의한 성능향상)

  • Nam, K.C.;Kim, S.C.;Kim, D.W.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.399-402
    • /
    • 1997
  • It is important to find a accurate root canal length or successful endodontic therapy. By X-ray method takes a long time and difficult in a curved canal. After developed electronic apex locator has allowed to measure the root canal length with easy, in a short time also in a curved canal. But most electronic apex locators have the disadvantage which is too short reading or sometimes the measurement itself becomes impossible if there are electrolytes in the canal. To overcome this drawback, impedance ratio method has been developed. In this study, we have developed frequency dependent electronic apex locator to minimize the interference of electrolytes. And based on that also some error in clinic use, we added the other method. Difference of two signals which are used in calculation of impedance ratio was can be represent the status of root canal fluid. As a result, using impedance ratio method and auto-calibration by voltage difference method can reduce the measurement error.

  • PDF

Design of a Broadband Quasi-Yagi Antenna with a 2:1 Impedance Bandwidth Ratio (2:1 임피던스 대역폭 비를 가지는 광대역 quasi-Yagi 안테나 설계)

  • Lee, Jong-Ig;Yeo, Jun-Ho;Park, Jin-Taek
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.760-765
    • /
    • 2012
  • In this paper, we studied a design method for a quasi-Yagi antenna (QYA) with broadband characteristics of an impedance bandwidth ratio greater than 2 : 1 and a gain > 4 dBi. The QYA is fed by a microstrip line fabricated on a coplanar strip line and it consists of 3 elements; a planar dipole, a nearby director close to the dipole, and a ground plane reflector. By placing a wide rectangular patch-type director near to the dipole driver, broadband characteristics are achieved. An optimized 3-element QYA for operation over 1.6-3.5 GHz (bandwidth ratio 2.2 : 1) is fabricated on an FR4 substrate with a size of 90 mm by 90 mm and tested experimentally. The results show an impedance bandwidth of 1.56-3.74 GHz (bandwidth ratio 2.4 : 1) for VSWR < 2, a peak gain of 4.2-6.3 dBi, and a front-to-back ratio (FBR) > 13.6 dB within the bandwidth.

Spread Spectrum Impedance Measurements for Rejecting Interference (간섭제거를 위한 대역확산 임피던스 측정)

  • Kang, Hyun-Kag;Jang, Yong-Gyu;Hwang, In-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.75-77
    • /
    • 2005
  • When measuring impedance of electronic component and so on, even the small size can reject the interference to shielding object. But, the interference through human body is grown when measuring bioimpedance without establishing shield specially. Consequently, when measuring bioimpedance in this paper, it proposed impedance measurement method to take advantage of spread spectrum technology, so that can reject the interference without establishing shield specially. Spread spectrum impedance measurement method to propose in this paper can reject the interference signal that occurring from medical instruments in the human body, the interference signal that is flowed in from surrounding environment when measuring impedance. It improved SJR(signal to jamming ratio) about 22dB than conventional method that actually realize and experiment spread spectrum impedance measurement method.

  • PDF

Prediction of Reservoir Properties Using Extended Elastic Impedance Inversion (확장 탄성 임피던스 역산을 이용한 저류층 물성 예측)

  • Kim, Hyeonju;Lee, Gwang H.;Moon, Seonghoon
    • Economic and Environmental Geology
    • /
    • v.48 no.2
    • /
    • pp.115-130
    • /
    • 2015
  • Extended elastic impedance (EEI) is an extension of elastic impedance (EI) which is a generalization of acoustic impedance (AI) for nonzero angles of incidence and can be tuned to be proportional to reservoir properties. In this study, we evaluated EEI inversion by estimating the P-($V_p$) and S-wave velocities ($V_s$), P-wave to S-wave velocity ratio ($V_p/V_s$), and Poisson's ratio of the Second Wall Creek Sand of the Teapot Dome field, Wyoming, USA. We also applied the EEI inversion technique to estimate porosity, gamma-ray values, and density of the Second Wall Creek Sand. Data used in the study include 3-D pre-stack seismic data from the southern part of the field and four wells, selected from a large well database. The $V_s$ logs at the wells were constructed from the $V_p$ logs using the empirical relationships. The percent prediction errors for the four velocity properties are less than about 5% except for Poisson's ratio at one well, supporting that the EEI inversion can be used in the prediction of rock properties. However, the results from the EEI inversion analysis of porosity, gamma-ray values, and density at the wells were unsatisfactory and thus these properties, which are not directly computed from velocities, may not be suitable for EEI inversion.

Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change (커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현)

  • Jeong, Do-Un;Bae, Jin-Woo;Shon, Jung-Man;Yae, Su-Yung;Choi, Byeong-Cheol;Nam, Ki-Gon;Kim, Cheol-Han;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

Study on Size-Reduced λ/4 Impedance Transformer using T-Equivalent Circuit (T형 등가회로를 이용하여 크기를 감소시킨 λ/4 임피던스 변환기의 연구)

  • Tae-Soon Yun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.595-600
    • /
    • 2023
  • In this paper, a modified equations of the T-equivalent circuit of the transmission line with the arbitrary electrical length is suggested. The suggested equations can be calculated without limitation of the equal branch-line. So, a modified T-equivalent circuit can be made with the arbitrary position of the open-stub. Also, the modified T-equivalent circuit can be applied in the arbitrary electrical length and impedance of the transmission line. For example, the λ/4 impedance transformer is converted with 4 divided T-equivalent circuit. The converted λ/4 impedance transformer has the size reduction ratio of 39.4%.

Calculation of Self-radiation Impedance for a Rectangular Transducer (장방형 트랜스듀서의 자기방사 임피던스 계산)

  • 이기욱;김무준;하강열;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.85-89
    • /
    • 2000
  • In this paper, by extending the previously developed self- and mutual-radiation impedance calculation method for a regular-square vibrating surface by using numerical series, we proposed a method to obtain the self-radiation impedance of a rectangular transducer with an arbitrary integer ratio of the length to width. The proposed method exhibits high accuracy and a short computation time. After investigating the accuracy and computation time as the number of elements changes, we have calculated the self-radiation impedance of several rectangular transducers, and compared the results with those in the literature.

  • PDF

Development of Power System Impedance Analyzer on the Electric Railway (전기철도 급전계통 임피던스 분석장치 개발)

  • Lee, Chang-Mu;Chang, Sang-Hoon;Han, Moon-Seob;Oh, Kwang-Hae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.387-389
    • /
    • 1998
  • For the continuous and exact measurement of load impedance of AC power system on the electric railway, this paper presents a method to show the load area to resistance(R)-reactance(X) plane of impedance plane. The load area is presented in terms of impedance which is in the ratio of voltage and current continuously measured and impedance plane indicates the protection area of fault locator. The proposed method is verified its reasonability by computer simulation, and using this method we will develop the power system impedance analyser which is available actual application.

  • PDF

A Study on the Impact of the Impedance Change of 345[kV] Power Transformers on Overall System Performance (345[kV] 전력용 변압기 %임피던스 변화에 따른 계통영향 분석)

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Song, Ji-Young;Kim, Tae-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.140-149
    • /
    • 2011
  • This paper deals with the impact analysis of the impedance change of 345/154[kV] power transformers on the KEPCO system's overall performance. Through the steady-state and dynamic analysis of power system, the maximum available impedance of power transformers were determined. Checking violation of short-circuit current ratings and transformer overload, parallel operation of power transformers, calculation of voltage variation ratio according to the impedance changes of power transformers are included in the steady-state analysis. In addition, transient and voltage stability analysis are also performed in the study. Available magnitudes to be able to change the impedance of the transformers in KEPCO system are finally determined in the paper.