• 제목/요약/키워드: Impedance Parameter

검색결과 283건 처리시간 0.022초

음향 입사파를 고려한 수치적 임피던스 경계조건의 보정 (Modifications of Numerical Impedance Boundary Conditions Considering Incident Acoustic Pressure)

  • 김민우;박용환;김성태;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.344-348
    • /
    • 2007
  • The acoustic liner has been used for the suppression of noise. The impedance characteristics of the acoustic liner are increased by the incident pressure. For the estimation of the acoustic liner on the incident acoustic pressure effect, the modified impedance model is suggested on the basis of the GE impedance prediction model. The modified impedance model is originated from the 3 parameter impedance model, and extended to the incident pressure parameter. The modified model is applied on the simple duct analysis with variant source pressure. Through the computation, it is observed that the fore directivity patterns of the duct are varied by the incident SPL level.

  • PDF

Critical Length Estimation of Counterpoise Subjected to Lightning Stroke Currents

  • Lee, Bok-Hee;Yoo, Yang-Woo;Kim, Jong-Ho
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.106-113
    • /
    • 2011
  • The conventional grounding impedance of a counterpoise is calculated as a function of the length of the counterpoise by use of the distributed parameter circuit model with an application of the EMTP(Electromagnetic Transient Program). The adequacy of the distributed parameter circuit model is examined and verified by comparison of the simulated and the measured results. The conventional grounding impedance of the counterpoise is analyzed for the first short stroke and subsequent short stroke currents. As a result, the simulated results show that the minimum conventional grounding impedance gives at a specified length of the counterpoise. The shorter the time taken to reach the peak of injected currents, the shorter the length of the counterpoise having the minimum conventional grounding impedance. We also present the critical lengths of the counterpoise for short stroke currents as a function of soil resistivity. Based on these results, it is necessary to compute the length of the counterpoise in a specified soil resistivity which satisfies both the low conventional grounding impedance requirement whilst also providing a suitable ground resistance in order to obtain an economical design and installation of the counterpoise.

Simulations of Frequency-dependent Impedance of Ground Rods Considering Multi-layered Soil Structures

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.531-537
    • /
    • 2009
  • Lightning has a broad frequency spectrum from DC to a few MHz. Consequently, the high frequency performance of grounding systems for protection against lightning should be evaluated, with the distributed parameter circuit model in a uniform soil being used to simulate grounding impedances. This paper proposes a simulation method which applies the distributed parameter circuit model for the frequency-dependent impedance of vertically driven ground rods by considering multi-layered soil structures where ground rods are buried. The Matlab program was used to calculate the frequency-dependent ground impedances for two ground rods of different lengths. As a result, an increase of the length of ground rod is not always followed by a decrease of grounding impedance, at least at a high frequency. The results obtained using the newly proposed simulation method considering multi-layered soil structures are in good agreement with the measured results.

임피던스 성분을 이용한 매입형 영구자석 전동기의 고정자 절연파괴 고장의 초기 검출 기법 (Early Detection Technique in IPM-type Motor with Stator-Turn Fault using Impedance Parameter)

  • 정채림;김경태;허진
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.612-619
    • /
    • 2013
  • This paper proposes an early diagnosis technique for the stator-turn fault (STF) in an interior permanent magnet (IPM)-type brushless DC (BLDC) motor using the impedance parameter. We have analyzed the varying characteristics owing to the STF through various experiments and the finite element method (FEM). As a result, we have presented a simple method for fault detection. This technique can be applied without requiring a fast Fourier transform (FFT) and the calculation of the negative-sequence impedance. The fault detection system works on the basis of the comparison the measured impedance with the database impedance. The variations in the characteristics owing to the STF as well as the proposed technique have been verified through the simulation and experiment.

특성임피던스 분석을 사용한 커넥터 성능향상 (Improvement of Connector Performance Using Analysis of Characteristic Impedance)

  • 양정규;김문정
    • 대한전자공학회논문지TC
    • /
    • 제48권9호
    • /
    • pp.47-53
    • /
    • 2011
  • 본 논문에서는 커넥터의 특성임피던스 추출, 분석 방법 및 설계 변경 방법을 제안하고 임피던스를 정합하여 신호 전달 특성을 개선한다. 3차원 FEM(Finite Element Method) 전자기장(Electro-Magnetic Field) 시뮬레이터를 이용하여 커넥터의 S-파라미터를 계산하고 반사손실 및 삽입손실을 추출한다. 커넥터의 신호 전달 특성은 반사손실이 0.9 GHz 이후부터 -20 dB 이상의 값으로 높게 나타났다. 신호 전달 특성이 낮은 원인을 파악하기 위해서 회로 해석 시뮬레이터를 이용하여 커넥터의 등가 회로 모델을 추출하고 특성임피던스를 계산하였다. 커넥터의 특성임피던스는 $90.3{\Omega}$으로 임피던스 부정합이 발생하여 신호 전달 특성이 저하되었다. 따라서 신호 전달 특성을 개선할 목적으로 임피던스를 정합하기 위해서 커넥터의 커패시턴스를 증가시켰다. 이러한 설계 방안으로 커넥터 신호선의 유효 면적을 확장하고, 커넥터의 몸체 소재로 고유전체를 사용하였다. 설계 변경된 커넥터의 특성임피던스는 $58.6{\Omega}$으로 임피던스 정합에 보다 근접하여 커넥터의 반사손실이 대략 10 dB 향상되었다. 신호선의 유효 면적 증가에 의한 반사손실 개선과 고유전체의 적용으로 전자기파의 신호선 주변 집중에 의해서 삽입손실 또한 개선되었다.

Frequency-dependent grounding impedance of the counterpoise based on the dispersed currents

  • Choi, Jong-Hyuk;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.589-595
    • /
    • 2012
  • When surges and electromagnetic pulses from lightning or power conversion devices are considered, it is desirable to evaluate grounding system performance as grounding impedance. In the case of large-sized grounding electrodes or long counterpoises, the grounding impedance is increased with increasing the frequency of injected current. The grounding impedance is increased by the inductance of grounding electrodes. This paper presents the measured results of frequency-dependent grounding impedance and impedance phase as a function of the length of counterpoises. In order to analyze the frequency-dependent grounding impedance of the counterpoises, the frequency-dependent current dissipation rates were measured and simulated by the distributed parameter circuit model reflecting the frequency-dependent relative resistivity and permittivity of soil. As a result, the ground current dissipation rate is proportional to the soil resistivity near the counterpoises in a low frequency. On the other hand, the ground current dissipation near the injection point is increased as the frequency of injected current increases. Since the high frequency ground current cannot reach the far end of long counterpoise, the grounding impedance of long counterpoise approaches that of the short one in the high frequency. The results obtained from this work could be applied in design of grounding systems.

음향 임피던스를 해저면 입력인자로 이용하는 수중음장 계산 (Computation of Underwater Acoustic Field Using Acoustic Impedance as an Input Parameter for the Ocean Bottom)

  • 이성욱;오택환;나정열;이필호;윤종락
    • 한국음향학회지
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2006
  • 천해에서의 수중음장 계산에서 음향 임피던스를 해저면 입력인자로서 도입하는 방안의 가능성을 고찰하였다. 먼저 탄성 해저면에서의 음파반사 특성을 고찰한 결과, 임계 접지각 이하에서 음향 임피던스는 접지각이 거의 $0^{\circ}$에 가까울 때의 임피던스 $Z_0$ 1개 값으로 근사가 가능함을 나타내었다. 이러한 특성과 'effective depth' 개념을 접목시켜 전달손실을 계산한 결과, 수중음장 계산에서 임피던스를 해저면 음향 특성을 나타내는 입력인자로 사용하는 것이 가능성이 있음을 확인하였다.

병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석 (An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel)

  • 이복희;조성철;성창훈
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

탄소접지극 접지임피던스의 주파수의존성과 과도응답특성의 해석 (Analysis of Transient Response Behavior and Frequency-Dependent Ground Impedances of the Carbon Ground Electrodes)

  • 이복희;이강수;김유하;엄상현
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • This paper presents transient response behavior and frequency-dependent ground impedance of a single carbon ground electrode. The ground impedance of the carbon ground electrode was measured as a function of frequency of injected currents and simulated by using the distributed parameter circuit model with due regard to the frequency-dependent soil parameters, and the transient response behavior of the carbon ground electrode against impulse currents were investigated. As a consequence, the frequency-dependent ground impedance of the carbon ground electrode showed the capacitive behavior, that is, the ground impedance decreases with increasing the frequency of injected currents and lowers at the fast front time of impulse current. It was found that the carbon ground electrode is effective in grounding system for lightning protection. The ground impedance simulated with due regard to the frequency-dependent soil parameters was in good agreement with the measured data. The adequacy of the simulation technique and the distributed parameter circuit model for the carbon ground electrode was verified. It is expected that the simulation methodology, which analyzes the frequency-dependent ground impedance of the carbon ground electrode proposed in this work, can be used in the design of a grounding system for protection against lightning.