• 제목/요약/키워드: Impact pulse

검색결과 181건 처리시간 0.025초

맥파 스트레스 지수를 활용한 도시철도 건설공사자의 안전보건관리 방안에 관한 연구 (A Study on the Safety and Health Management Plan of Subway Construction Workers using Macpa Stress Index)

  • 채정식;이유정;이종빈;장성록
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.102-107
    • /
    • 2022
  • South Korea will soon be a super-aged society, as more than 20.6% of its population will be 65 years and older by 2025. As of 2022, 17.5% of the total population in South Korea is 65 years and older, which exceeds the set threshold for an aged society, where more than 14% of the population is 65 years and older. The proportion of older subway construction workers has increased. Aging workers and their work stress negatively impact their workability. A previous study demonstrated that the stress index measured using the uBioMacpa measurement device (Macpa stress index) had a significant correlation with work stress in South Korea. The device tests vascular health and measures stress levels via Macpa signal analysis. In this study, the pulse waves of subway construction workers were measured using uBioMacpa to identify their stress levels. The stress levels were analyzed by age, years of service, job position, employment type, and work type. Herein, these statistics could not be easily represented by a normal distribution; therefore, the Kruskal-Wallis test, a nonparametric statistical method, was used for the analysis of data. The results showed that age, job position, employment type, and working type affected the Macpa stress index and the stress levels of workers increased with age. In terms of job position, technical engineers were more stressed than other workers because of their poor working environment. In terms of employment type, daily-wage workers were more stressed than other workers. In terms of working type, tunneling, waterproofing, and construction scored the highest Macpa stress indexes without any significant difference, whereas earthworks scored the lowest. Based on the analysis of Macpa stress index, safety and health management plans were proposed to reduce the stress levels of workers. Moreover, a manual for efficient stress management must be developed for subway construction workers.

결핵후 폐손상에서 한국어판 St. George's Respiratory Questionnaire를 이용한 건강 관련 삶의 질 평가 (Health-related Quality of Life Measurement with St. George's Respiratory Questionnaire in Post-tuberculous Destroyed Lung)

  • 이병훈;김영삼;이기덕;이재형;김상훈
    • Tuberculosis and Respiratory Diseases
    • /
    • 제65권3호
    • /
    • pp.183-190
    • /
    • 2008
  • 연구배경: 결핵후 폐손상 환자에서 나타나는 다양한 폐기능 장애는 이들의 건강관련 삶의 질에 심각한 영향을 주고 있을 것으로 추정되나 이에 대한 연구는 거의 없다. 결핵후 폐손상 환자에서의 임상적 특징을 알아보고, 나아가 만성 호흡기 질환에서 건강관련 삶의 질을 평가하는 도구로 널리 사용되고 있는 세인트조지 호흡기설문(St. George's Respiratory Questionnaire, SGRQ)의 한국어판이 결핵후 폐손상 환자에서도 유용하게 사용될 수 있을지를 평가하고자 하였다. 방 법: 폐결핵의 치료가 종결된 지 6개월 이상 경과하였으며 흉부 단순 촬영상 한 측 폐 1/2 이상의 손상이 관찰되는 결핵후 폐손상 환자에서 SGRQ를 시행하고 폐활량검사, 운동부하 심폐기능검사, HRCT의 결과와 비교하여 연관성을 살펴보고 SGRQ의 결핵후 폐손상의 평가에 있어 신뢰도와 타당도를 검정하였다. 결 과: 폐기능검사에서 혼합형 환기장애와 폐쇄성 환기장애는 각각 10명(45.0%), 9명(40.9%)에서 관찰되었다. 운동부하 심폐기능검사에서 평균 $VO_2max%$ predicted는 $39.0{\pm}10.9%$ 평균 $O_2$ pulse% predicted는 $61.3{\pm}13.6%$로 감소되어 있었다. 한국어판 SGRQ는 영향영역점수가 평균 $27.8{\pm}18.5$로 증상영역 평균 $53.9{\pm}20.9$ 활동영역 평균 $50.8{\pm}27.3$에 비하여 점수가 낮았다(p<0.05, p<0.01). Cronbach's alpha coefficient는 각각의 영역과 총 점수에서 모두 0.7 이상이었다. 총 점수는 $FEV_1%$ predicted(r=-0.46, p<0.05), 동맥혈산소포화도(r=-0.60, p<0.05), HRCT 비손상 기관지폐구역수(r=-0.52, p<0.05) 등과 관련이 있었다. 결 론: 결핵후 폐손상환자 대부분에서 폐쇄성 환기장애가 동반되었다. 한국어판 SGRQ는 결핵후 폐손상 환자의 삶의 질을 평가하는데 적절한 타당도와 신뢰도를 보여주었다.

도심 수목원에서의 경관감상과 산책이 인체의 생리적 안정에 미치는 영향 (Physiological Effects of Walking and Viewing on Human at a Urban Arboretums)

  • 박범진;가재남;이민선;김선아;박민우;최윤호;정다워;권치원;염동걸;박순주;이준우;김건우
    • 한국산림과학회지
    • /
    • 제103권4호
    • /
    • pp.664-669
    • /
    • 2014
  • 본 연구는 도시림에서의 경관감상과 산책이 인체의 생리적 안정에 미치는 영향을 규명하기 위해 수행되었다. 실험은 대전광역시에 위치한 한밭수목원에서 실시하였으며, 대조실험은 대전시청 앞에서 실시하였다. 20대 남자 대학생 24명(평균나이 $21.1{\pm}2.5$세)이 피험자로 참여하였고, 피험자를 세 그룹으로 나누어 수목원 내 소나무 숲, 수목원 내 연못, 도시 세 장소에 무작위 배치하였으며, 자리에 앉아 10분간 경관을 감상한 후 15분 동안 산책을 실시하였다. 측정지표로써 HRV, 혈압, 맥박수를 이용하여 생리적 변화를 측정하였다. 그 결과 도심 수목원 내에서 경관감상과 산책을 했을 때 도심과 비교하여 통계적으로 유의한 HF 성분의 증가와 수축기 혈압의 감소를 확인할 수 있었다. 본 연구를 통해 도심 수목원에서의 경관감상 또는 산책과 같은 활동이 도시민의 생리적 안정감을 향상시키는데 효과가 있음을 알 수 있었다.

하천의 횡적 연결성 유무에 따른 홍수터 식생 구조의 비교 (Comparison of the Floodplain Vegetation Structure According to Existence of Lateral Connectivity in Streams)

  • 추연수;진승남;조현석;조강현
    • 한국습지학회지
    • /
    • 제19권3호
    • /
    • pp.327-334
    • /
    • 2017
  • 하천의 수로-홍수터 생태계에서 주기적인 범람은 물, 영양염류, 하상재료 및 생물을 상호 교환시킴으로써 생물다양성과 생태계 서비스를 증진시킨다. 그러나 치수와 토지이용의 목적으로 건설된 제방에 의하여 하천의 횡적 연결성이 훼손되었다. 본 연구에서는 하천의 횡적 연결성 유무에 따른 홍수터 식생의 특성을 비교하기 위하여, 청미천, 섬강, 황구지천, 만경강, 고막원천 및 보성강에서 본류와 수리적으로 연결된 홍수터와 제방에 의해 단절된 홍수터에서 지형, 토양환경요인과 식생 구조와 분포를 조사하였다. 토양의 수분과 점토 함량은 횡적 연결성이 단절된 홍수터에서 연결된 홍수터보다 많았다. 환경요인 자료를 이용한 주요인분석 (PCA)의 결과에서 단절된 홍수터와 연결된 홍수터의 환경은 수분함량, 토성 및 식생 분포고도에 의하여 구분되었다. 식생 자료를 이용한 탈경향대응분석 (DCA)의 결과에 따르면 홍수터의 식생은 다양한 생활형의 수생식물이 우점하는 단절된 홍수터와 교란에 강한 습생식물이 우점하는 연결된 홍수터로 분리되었다. 결론적으로 제방에 의해 횡적 연결성이 단절된 홍수터에서는 정수성 습지 환경에서 수생식물이 우점하는 습지 식생이 분포하여 수로와 연결된 홍수터의 식생과 차이를 나타내었다.

음악을 사용한 지시적 심상이 입원 정신질환자의 기분상태 및 생리적 변화에 미치는 영향 (The Effects of Guided Imagery Activities Using Music on Mood States, and Physiological Responses of Psychiatric Inpatients)

  • 조현주;문지영
    • 재활복지
    • /
    • 제20권1호
    • /
    • pp.113-130
    • /
    • 2016
  • 본 연구는 입원 중인 정신질환자를 대상으로 음악을 사용한 지시적 심상이 기분상태와 생리적 변화에 미치는 영향을 알아보고자 시행되었다. 실험 기간은 2015년 7월 8일부터 17일까지이고 장소는 서울시 소재의 일 정신과 병원 폐쇄병동에서 시행되었다. 총 54명의 대상자 중 실험집단 27명은 음악을 사용한 지시적 심상 음원을 11분간 감상하였고, 대조집단 27명에게는 11분간 책을 제공하고 보통의 상태로 지내게 하였다. 음악을 사용한 지시적 심상이 변화시키는 심리적 영향과 생리적 영향을 알아보기 위해 실험의 사전 사후에 기분상태척도(K-POMS-B) 및 수축기 이완기 혈압, 맥박 수, 말초 피부온도를 측정하였다. 수집된 자료를 SPSS 23.0의 독립 t검증과 대응 t검증으로 분석한 결과, 실험집단의 기분상태의 사전-사후 총점과 하위 6개 유형 중 '긴장, 불안, 우울, 분노, 활력, 피로'의 5개 영역에서 유의한 결과를 보였다. 또한, 실험집단과 대조집단 간의 변화를 분석한 결과, 기분상태 총점과 하위 6개 영역 가운데 '긴장, 우울, 활기, 피로'의 4개 영역에서 유의한 결과가 나타났다. 한편, 생리적 반응에서는 실험집단의 사전과 사후 총점에서 말초 피부온도에서 유의하게 상승된 결과를 보였으며, 실험집단과 대조집단 간의 변화에서도 말초 피부온도에서 유의한 결과가 나타났다. 이상의 연구 결과를 통해 음악을 사용한 지시적 심상이 단회기로 시행되었을 때 입원 정신질환자의 기분상태를 긍정적으로 변화시키고, 생리적으로는 긴장이완의 효과가 있다는 것을 알 수 있었다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

과체중과 비만 청소년에서 대사증후군과 비만이 심혈관에 미치는 영향 (Metabolic syndrome in the overweight and obese adolescents and the impact of obesity on the cardiovascular system)

  • 홍영미;송영환;김혜순;박혜숙;민정혜;정조원;김남수;노정일
    • Clinical and Experimental Pediatrics
    • /
    • 제52권10호
    • /
    • pp.1109-1118
    • /
    • 2009
  • 목 적 : 대사증후군이란 기저 요인으로 비만과 인슐린 저항성이 있는 상태에서 고지혈증, 고혈압, 혈당상승 등 위험인자들이 유발되고, 여기서 동맥경화가 발생하게 되어 심혈관질환으로 진행하게 되는 상태를 말한다. 본 연구 목적은 비만 청소년에서 대사증후군의 빈도를 구하고, 비만이 심기능에 미치는 영향을 알아 보고자 본 연구를 실시하였다. 방 법 : 서울 시내에 소재하는 1개의 중학교 684명(남자 402명, 여자 282명)의 청소년을 대상으로 혈압, 허리둘레, 생체전기저항법에 의한 체성분분석을 실시하였고, 1998년도 소아과학회에서 측정한 체질량지수를 기준으로 85 백분위수 이상인 과체중과 비만 청소년에서 공복시 혈액 검사(혈당, 중성지방, LDL-콜레스테롤, HDL-콜레스테롤, AST, ALT, hs-CRP)를 측정하였다. 심초음파를 이용하여 심장관련 지표들을 측정하였고, VP-1000 기계를 사용하여 맥파 속도와 발목 상완 지수를 측정하였다. 결 과 : 대사증후군의 빈도는 과체중군과 비만 청소년에서 19.4%, 비만 청소년에서는 50.8%였다. 과체중과 비만 청소년에서 수축기 혈압, 이완기 혈압, 신장, 체중, 체질량지수, 비만지수, 체지방량, 체지방률, 허리둘레는 대사증후군이 있는 경우 대사증후군이 없는 경우보다 유의하게 높았다. 과체중과 비만청소년 중에서 대사증후군이 있는 경우 중성지방, AST, ALT, hs-CRP 등이 유의하게 높았고, HDL-콜레스테롤은 유의하게 낮았다. 대사증후군을 가진 경우 심장 초음파에 의해 측정된 이완기 시간, 수축기 시간이 유의하게 짧았고, E파 감속 시간은 유의하게 길었다. 심박동수와 좌측 상완 발목 맥파 속도는 대사증후군을 가진 경우 대사증후군이 없는 경우에 비해 유의하게 증가하였다. 결 론 : 비만 청소년에서 비만, 고혈압, 고지혈증을 비롯한 대사증후군의 구성 요소들이 관찰되였고, 대사증후군의 빈도가 높으므로 적극적인 비만 예방 및 치료가 중요하다.

여론조사보도에 대한 제3자효과 검증: 온라인 여론조사를 주목하며 (Measuring the Third-Person Effects of Public Opinion Polls: Focusing On Online Polls)

  • 김성태;라스 윌나트;데이비드 위버
    • 한국언론정보학보
    • /
    • 제32권
    • /
    • pp.49-73
    • /
    • 2006
  • 이 연구는 사람들이 전통적인 여론조사와 온라인 여론조사를 통해 얻어진 결과를 어떻게 다르게 인식하는가를 제3자효과론 (Third Person Effects)을 중심으로 살펴보았다. 미디어의 영향이 본인보다 다른 사람에게 더 클 것이라는 제 3자효과론은 그 동안 미디어효과 연구분야에서 폭넓게 적용되어 왔다. 하지만 최근 인터넷을 이용한 온라인 여론조사의 광범위한 사용으로 과연 이러한 여론조사에서, 특히 우리가 기존에 사용해왔던 전화를 통한 무작위 표본조사와 대표성이 약한 온라인 여론조사의 차이를 고려할 때, 실질적으로 미디어 이용자 입장에서는 얼마나 그 차이를 인식하는지는 매우 중요한 연구과제라 할 수 있다. 뿐만아니라, 서로 다른 두 가지 유형의 여론조사의 결과가 수용자에게 미치는 영향 측면에서 서로 다른 크기의 제 3자 효과가 나타나는지에 대한 관심도 커질 수밖에 없다. 이를 위해서 서베이와 실험연구 두 방법을 병용하여 이 문제에 대한 좀더 심층적인 분석을 시도하였다.

  • PDF

지자기폭풍 기간 동안의 태양풍 동압력 펄스에 관한 통계적 분석 (A STATISTICAL ANALYSIS OF SOLAR WIND DYNAMIC PRESSURE PULSES DURING GEOMAGNETIC STORMS)

  • 백지혜;이대영;김경찬;최정림;문용재;조경석;박영득
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권4호
    • /
    • pp.419-430
    • /
    • 2005
  • 이 연구에서는 지자기 폭풍의 주상 기간 동안 발생하는 태양풍 동압력 펄스에 대한 통계적 분석을 하였다. 이를 위해 먼저 1997년부터 2001년까지 5년간의 기간으로부터 지자기 폭풍 지수인 Dst 값이 -50nT 이하인 지자기 폭풍을 모두 111개 얻었다. 이러한 지자기 폭풍의 주상기간 동안에 발생한 태양풍 동압력 펄스를 정확히 조사하기 위해 태양풍 자료 뿐만 아니라 지구 저위도 여러 관측소에서 관측된 지자기 수평 성분 H값을 이용하였다. 즉 동압력 펄스가 자기권에 충돌하면 저위도 H 값이 전 지구적인 증가를 보여야 한다는 사실을 이용하였다. 이러한 과정을 통해 얻은 통계적 결과는 다음과 같다. 첫째, 자기 폭풍 중에 발생하는 H의 증가는 평균적으로 그 크기가 자기 폭풍의 강도와 비례하는 경향을 보인다. 이는 강한 자기폭풍일 수록 강한 태양풍 펄스를 동반한다는 것이다. 둘째로 자기폭풍 중에 발생하는 동압력 펄스의 발생 빈도 역시 자기 폭풍의 강도와 비례한다. 셋째, 동압력 펄스 발생 빈도가 0.4회/hr 이상인, 즉 2.5시간에 1회 이상의 동압력 펄스를 동반하는, 지자기 폭풍은 여기서 다루어진 전체 지자기 폭풍 중 약 $30\%$를 차지한다. 2.5시간은 서브스톰의 평균 지속 시간으로 볼 수 있으며, 따라서 자기 폭풍중에 서브스톰이 연속적으로 발생하는 것 만큼 자주 동압력 펄스가 나타나는 자기폭풍이 전체의 $30\%$라는 것이다. 한편 이러한 동압력 펄스의 기원을 이해하기 위해 먼저 지자기 폭풍 유도체에 대해 조사하였다. 그 결과 여기서 다루어진 지자기 폭풍의 약 $65\%$가 CME(Coronal Mass Ejection)에 의해 발생되었고 CIR(Corotating Interaction Regions)과 Type II bursts에 의해 발생한 것이 각각 6.3, $7.2\%$인 것으로 나타났다. 그런데 CME에 의해 발생된 지자기폭풍 중에서 $70\%$ 이상이 그 주상 기간이 CME와 충격파 사이의 공간인 sheath 영역 혹은 CME 앞부분에 해당되는 것으로 나타났다. 따라서 이들 지자기폭풍 주상기간에 빈번히 발생하는 동압력 펄스는 CME와 충격파 사이의 sheath 영역, 그리고 CME 앞부분 영역에서의 빈번한 태양풍 밀도 증가에 기인하는 것으로 보인다.