• 제목/요약/키워드: Impact machine

검색결과 659건 처리시간 0.024초

임팩트 볼을 활용한 바닥충격음 측정 및 평가 (Floor Impact Noise Measurement and Evaluation Method Using Impact Ball)

  • 전진용;정정호
    • 한국소음진동공학회논문집
    • /
    • 제15권10호
    • /
    • pp.1160-1168
    • /
    • 2005
  • Floor impact noise isolation performance of reinforced concrete floors was investigated through new measurement method using impact bail. Strong impact force in Bow frequency band below 63 Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight Impact noise but heavy-weight impact noise measurement and evaluation using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

Analysis of The Behavior of Kurtosis By Simplified Model of One Sided Affiliated Impact Vibration

  • Takeyasu, Kazuhiro;Higuchi, Yuki
    • Industrial Engineering and Management Systems
    • /
    • 제4권2호
    • /
    • pp.192-197
    • /
    • 2005
  • Among many amplitude parameters, Kurtosis (4-th normalized moment of probability density function) is recognized to be the sensitive good parameter for machine diagnosis. Kurtosis has a value of 3.0 under normal condition and the value generally goes up as the deterioration proceeds. In this paper, simplified calculation method of kurtosis is introduced for the analysis of impact vibration with one sided affiliated impact vibration which occurs towards the progress of time. That phenomenon is often watched in the failure of such as bearings’ outer race. One sided affiliated impact vibration is approximated by one sided triangle towards the progress of time and simplified calculation method is introduced. Varying the shape of one sided triangle, various models are examined and it is proved that new index is a sensitive good index for machine failure diagnosis. Utilizing this method, the behavior of kurtosis is forecasted and analyzed while watching machine condition and correct diagnosis is executed.

충격력 변화에 따른 공동주택의 중량 충격음 및 진동 특성 (The Characteristics of Heavy-weight Impact Sound and Vibration According to the Change of Impact Force in An Apartment Building)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.304-307
    • /
    • 2004
  • To reduce the structure-born sound by floor impact source in an apartment building, it is necessary to identify the relationship between floor impact sound and vibration. Various impact sources which were made by a bang machine and an impact ball were used for measurement of impact sound and vibration. The experimental results show that the linear relationship between floor impact sound and vibration was in existence despite of various floor impact sources.

  • PDF

TiC-SKH51 금속 복합재를 이용한 공작기계 주축 진동 억제에 관한 연구 (Suppression of Machine Tool Spindle Vibration by using TiC-SKH51 Metal Matrix Composite)

  • 배원준;김성태;김양진;이상관
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.262-267
    • /
    • 2020
  • 고속 가공과 저중량 설계에 대한 수요가 증가함에 따라, 공작기계 주축의 진동 발생 가능성이 증가하고 있다. 또한 초정밀 가공에서 주축의 진동은 공작물 표면 형상에 큰 영향을 끼치게 된다. 다양한 가공 공정의 가공 정밀도를 향상시키기 위해, 공작기계 주축 진동 문제를 해결하여야 한다. 이 논문에서, 공작기계 주축의 진동 억제를 위해 TiC-SKH51 금속 기지 복합재가 사용되었다. TiC-SKH51 복합재의 동적 특성을 확인하기 위해 충격 망치 시험을 수행하였다. FEA의 모드 분석 결과와 충격 망치 시험 결과를 비교하여 FEA의 신뢰성을 확인한 후, 공작기계 주축 모델의 해석이 실행되었다. FEA 결과로부터 진동 발생 억제를 위해 TiC-SKH51 복합재를 적용한 공작기계 주축이 사용될 수 있음을 확인하였다.

바닥충격음레벨 영향요인 분석 (An Analysis of the Influence Factors of Floor Impact Sound Levels)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.255-260
    • /
    • 2003
  • The regulation for floor impact sound level is expected to be amended to 50㏈(L$\_$i, Fmax, AW/) and below in heavy-weight impact sound and 58㏈(L'$\_$n, AW/) and below in light-weight impact sound in Korea. The purpose of this paper is to analyze the influence factors of floor impact sound levels in apartments. The influence factors were air pressure of bang machine, height of microphones, data acquisition rate, etc. The air pressure range of bang machine were from 2.2 Pa to 2.6 Fa. Five microphones were installed at a height of 0.5m, 0.7m, 0.9m, 1.2m, 1.5m or 1.7m from floor level. The floor impact sound level was varied about 1-3㏈(L$\_$i, Fmax, AW/) in heavy-weight impact sound according to the influence factors.

  • PDF

기계학습과 네트워크를 이용한 수학교육 연구의 영향력 판별 프로그램 개발 (Development of an impact Identification Program in Mathematical Education Research Using Machine Learning and Network)

  • 오세준;권오남
    • 한국수학교육학회지시리즈E:수학교육논문집
    • /
    • 제37권1호
    • /
    • pp.21-45
    • /
    • 2023
  • 본 연구는 수학교육에서 영향력 있는 논문을 판별하는 기계학습 프로그램 개발 연구이다. 이를 위하여 과학계량학의 관점에서 논문의 영향력을 조명하고, 수학교육 연구 네트워크를 구성하고, 네트워크 중심성 지수인 PageRank로 수학교육 연구의 영향력으로 정의하였다. 영향력 있는 수학교육 연구를 판별하기 위하여 기계학습 모델을 설계하였으며, 이를 이용하여 영향력 있는 논문이 게재된 비율이 높은 학술지를 조사한 결과 Journal for Research in Mathematics Education(25.66%), Educational Studies in Mathematics(22.12%), Zentralblatt für Didaktik der Mathematik(8.46%), Journal of Mathematics Teacher Education(5.8%), Journal of Mathematical Behavior(5.51%) 순으로 나타났다. 수학교육 전문가들이 직접 논문을 읽고 질적으로 평가한 선행연구 결과와 유사한 결과를 기계학습 프로그램으로 도출할 수 있었다. 많은 인원과 시간이 필요했던 수학교육 연구의 영향력 평가를 인공지능을 이용하여 효율적으로 실시할 수 있었다는 점에서 의의가 있다.

중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구 (Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources)

  • 유승엽;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.

공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교 (Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data)

  • 윤창연;연준오;김명준
    • 한국소음진동공학회논문집
    • /
    • 제24권8호
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

바닥충격음 측정 및 차음 평가의 방향 (Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance)

  • 정정호;정영;서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석 (An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis)

  • 문대호;박홍근;황재승;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.