• Title/Summary/Keyword: Impact Sound Source

Search Result 96, Processing Time 0.021 seconds

Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings (수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측)

  • 김명준;김흥식;김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.

Performance of floor coverings by impact sound (실 충격원에 대한 바닥마감재 성능 분석)

  • Chung, Jinyun;Im, Jungbin;Lee, Sungchan;Kim, Kyoungwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure - (건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 -)

  • Yeon, Junoh;Kim, Kyoungwoo;Choi, Hyunjuong;Yang, Kwanseop;Kim, Kyungho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House (강재프레임 모듈러주택의 바닥충격음 성능평가)

  • Chun, Young-Soo;Bang, Jong-Dae;Kim, Gap-Deug;Yoo, Song-Lee
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.81-89
    • /
    • 2014
  • This paper presents various attempts to secure the floor impact sound insulation performance on the dry floor system of steel framed modular house that lately attracted domestic attention. Test results show that in the condition of using dry floor system of D31(D32), the light-weight impact noise performance records the top level in the floor impact sound insulation performance grading system. the heavy-weight floor impact noise performance meets the minimum sound level limit in the floor impact sound insulation performance grading system that enacted regulation on housing construction standards.

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

A Study on the Characteristic and Reproducibility of Floor Impact Sound Source (바닥충격음원의 특성과 재현성에 관한 연구)

  • Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.3 no.4
    • /
    • pp.23-31
    • /
    • 2003
  • From 1998, the number of household who live in apartment house outnumber that of household live in detached dwelling by 0.3% in Korea. As walls and floors are shared with neighbourhood in apartment houses, percent complaints to the impact noise from the upper floor was so high that it represents an important factor in apartment indoor noise. And the rate is closely correlate with children's running, playing and jumping. In this study, comparisons of standard impact source, such as Tapping Machine and Bang Machine, with real life impact sources were made in order to investigate acoustical characteristics between them. Also reproducibility tests for impact sound sources were carried out.

An Experimental Study on the Floor Impact Sound Measurement for the Apartment with Balcony Remodeled (발코니 확장 공동주택의 바닥충격음 측정에 관한 연구)

  • Park, Hyeon-Ku;Song, Guk-Gon;Park, Chan-Woong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.437-438
    • /
    • 2008
  • Analysis was carried out on the floor impact sound level between existing plan and enlarged plan with balcony remodeled. Because there is no standardized method to measure the floor impact sound for the apartment with balcony remodeled, two sets of sound source and receiver position were applied depending on whether it is enlarged or not. As a result, it is discovered that different positioning of sound source or receiver in the apartment with balcony remodeled could lead to different result.

  • PDF

An Analysis of the Influence Factors of Floor Impact Sound Levels (바닥충격음레벨 영향요인 분석)

  • 김경우;최현중;양관섭;이승언
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.255-260
    • /
    • 2003
  • The regulation for floor impact sound level is expected to be amended to 50㏈(L$\_$i, Fmax, AW/) and below in heavy-weight impact sound and 58㏈(L'$\_$n, AW/) and below in light-weight impact sound in Korea. The purpose of this paper is to analyze the influence factors of floor impact sound levels in apartments. The influence factors were air pressure of bang machine, height of microphones, data acquisition rate, etc. The air pressure range of bang machine were from 2.2 Pa to 2.6 Fa. Five microphones were installed at a height of 0.5m, 0.7m, 0.9m, 1.2m, 1.5m or 1.7m from floor level. The floor impact sound level was varied about 1-3㏈(L$\_$i, Fmax, AW/) in heavy-weight impact sound according to the influence factors.

  • PDF

Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure (벽식구조 표준시험동에서 중량충격음장에 관한 연구)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

The Characteristics of Heavy-weight Impact Sound and Vibration According to the Change of Impact Force in An Apartment Building (충격력 변화에 따른 공동주택의 중량 충격음 및 진동 특성)

  • 서상호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.304-307
    • /
    • 2004
  • To reduce the structure-born sound by floor impact source in an apartment building, it is necessary to identify the relationship between floor impact sound and vibration. Various impact sources which were made by a bang machine and an impact ball were used for measurement of impact sound and vibration. The experimental results show that the linear relationship between floor impact sound and vibration was in existence despite of various floor impact sources.

  • PDF