개선된 충격해머의 동역학적 모델 (Improved dynamic model of the impact hammer)

  • Lim, Byoung-Duk;Park, Jung-Hyun;Heo, Joon-Hyeok
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.372.1-372
    • /
    • 2002
  • Although impact hammer is widely used as a convenient excitation tool in structural modal testing, little is known about the dynamic charateristics of its impulse mechanism. Transmission of the impulsive force to the structure depends on the dynamic properties of the impact hammer as well as the stiffness of the tip. An improved dynamic model of the impact hammer is proposed in this study with numerical simulations based on this model. (omitted)

  • PDF

설문조사를 통한 소음 민감도에 따른 층간소음에 의한 성가심과 생활방해 연구 (A study on the annoyance and disturbance of floor impact noise according to noise sensitivity based on questionnaire survey)

  • 정정호;이성찬
    • 한국음향학회지
    • /
    • 제37권6호
    • /
    • pp.428-436
    • /
    • 2018
  • 소음에 대한 반응은 응답자의 소음 민감도에 따라 차이가 발생될 수 있다. 본 연구에서는 소음 민감도와 함께 층간소음에 대한 거슬림, 생활방해, 이웃에 대한 의견 등을 조사하였다. 설문조사 응답자를 소음 민감도 그룹별로 구분하고 소음 민감도 그룹별 층간소음의 거슬림, 생활방해 등에 대하여 비교하였다. 이를 통해 소음 민감도 설문조사 방법을 제시하였다. 설문조사는 서울, 경기 지역 공동주택 거주경험자 233명을 대상으로 층간소음에 의한 거슬림, 생활방해와 소음 민감도, 이웃에 대한 의견과 층간소음 발생 시 항의 방법에 대하여 조사하였다. 설문조사 결과 민감도 그룹을 3개로 나눈 경우 소음 민감도가 높은 그룹의 층간소음 거슬림과 생활방해 반응이 나머지 그룹과 유의한 차이가 있는 것으로 나타났다. 이웃에 대한 느낌 조사 결과 연령대가 증가함에 따라 이웃에 대한 긍정적 반응이 증가되는 것으로 조사되었다. 또한 이웃에 대해 긍정적 느낌을 갖는 그룹의 층간소음 거슬림, 생활방해 인식도 낮은 것으로 나타났다.

에틸렌-초산비닐 공중합체의 공중합 조성이 복합체의 충격음 흡수성능에 미치는 영향 (Influence of Chemical composition of Ethylene-Vinyl Acetate Copolymers on Impact Noise Damping of Composites)

  • 이현종
    • 임산에너지
    • /
    • 제18권2호
    • /
    • pp.55-61
    • /
    • 1999
  • 본 실험에서는 화학조성이 다른 일련의 에틸렌/초산비닐 공중합체의 점탄성(또는 화학조성)이 목재/고분자/목재 샌드위치 복합체의 진동·충격음 흡수성능에 미치는 영향을 검토하였다. 그 결과는 다음과 같다. 복합체의 진동·충격음 흡수성능은 고분자의 분자 운동상태에 민감하다. 즉, 복합체의 진동·충격음 흡수성능 고분자가 시험온도에 있어서 유리전이 상태일 때(대략 초산 비닐 55∼75%) 가장 크며, 고분자가 고무상태(초산비닐 47∼20%) 또는 유리상태(초산비닐 100∼87%)일 때는 작다. 또한 유리전이상태의 고분자 적층재는 약 6∼12dB의 충격음 저감효과가 있었다.

  • PDF

완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구 (An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation)

  • 안재원;전명훈;이범식;이도헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

시간별 교통량 변화에 따른 환경오염지도(대기 및 소음) 구축방안에 관한 연구 (Hourly Environmental Pollution (Air Pollution and Noise) Mapping Method by the Traffic Volume Change)

  • 조동명;권우택;나영
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.485-494
    • /
    • 2007
  • Air pollution and traffic noise from roads distributed near residential area has been a major social problem. In this study, an environmental pollution map for a residential area of Shihung-city was made by an expectation model based on hourly traffic volume change. Using the result from the model, a plan to reduce population in the residential area was established. The result of the modelling is summarized as follows: 1. At peak traffic hours (18 o'clock), 301-500 degree in hazardous and $d_{25}$ degree (25% of the residents are suffering extremely from the noise) in noise pollution were predicted in Jeongwang Main Road in Shihung city. 2. The calculated critical pollutant standard index, PSI showed the air pollution level, especially PM-10 high enough to require re-entrainment. 3. It was expected air pollution would extensively extend over the area distribution of each degree. However, noise pollution problem was limited to the area near roads.

EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발 (The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form)

  • 박철용;김상훈;장동운;장철호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구 (A study on the performance test and acoustic design of interference type noise reduction device for railway noise)

  • 조준호;고효인
    • 환경영향평가
    • /
    • 제20권6호
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

바닥충격음 완충재의 동적특성과 소음저감 성능 비교 (Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad)

  • 양수영;이동훈;홍병국;송화영;이주원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

실 충격원에 대한 바닥마감재 성능 분석 (Performance of floor coverings by impact sound)

  • 정진연;임정빈;이성찬;김경우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

철도소음 영향평가를 위한 예측기술 동향 (A Tendency of Prediction Technique for the Assessment of Railway Noise)

  • 조준호;박영민;선효성;홍웅기
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.99-105
    • /
    • 2007
  • Since 1990s, the railway noise has been researched and developed in our nation. First of all, what's causing the noise and how to eliminate the cause of the noise must be found out. Secondly, cutting off the propagation path of the noise from the noise source to the receiving points. In this study the characteristics of prediction formula for the assessment of railway noise used in some nations including Korea were investigated. In order to develop the prediction formula of the railway noise, the noise radiated from railway vehicle, rails and sleepers, characteristics of noise barrier, velocity of train, ground effects, roughness should be analyzed and predicted. Especially, on the basis of acoustics, the characteristics of source are applied to acoustic power and directivity information.