• Title/Summary/Keyword: Imitation-Air$SF_6$

Search Result 10, Processing Time 0.039 seconds

Breakdown Characteristics Assess of Imitation-Air for Distribution Power Facilities (배전급 전력설비를 위한 제조공기의 절연성 평가)

  • Lee, Kwang-Sik;Do, Yeong-Hoei;Choi, Eun-Hyeok;Lee, Chang-Uk;Park, Kwong-Seoo;Kim, Lee-Kook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.114-119
    • /
    • 2008
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability are being required. We request urgently change a $SF_6$ for an environment friendly gas insulation material. In this paper the experiments of breakdown characteristics by pressure and gap change of Imitation-Air in model GIS(Gas Insulated Switchgear) were described. Also assess of breakdown characteristics about Imitation-Air and $SF_6$. It is considered in this paper that the results are fundamental data for electric insulation design of Distribution Power Facilities which will be studied and developed in the future. The pressure to be confronted to $SF_6$ gas 1[atm] for Distribution Power Facilities is Imitation-Air 3[atm]. And we could make an environment friendly gas insulation material with maintaining dielectric strength by Imitation-Air which generates a lower level of the global warming effect.

Breakdown characteristics of SF6 and Imitation Air in Temperature Decline

  • Lim, Chang-Ho;Choi, Eun-Hyeok;Kim, Do-Seok;Kim, Young-Su;Park, Won-Zoo;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.115-121
    • /
    • 2007
  • This paper describes experiments of the breakdown characteristics by temperature change of $SF_6$ gas and Imitation Air(I-Air) in model GIS(Gas Insulated Switchgear). From the results of the experiments, the breakdown characteristics classify the vapor stage of $SF_6$ according to Paschen's law, in which the stage of coexistence for gas & liquid of the voltage value increases. This results in large deviation and the breakdown of the voltage(VB) low stage as the interior of the chamber is filled with a mixture of $SF_6$ that is not liquefacted and remaining air that can not be ventilated. The ability of $SF_6$ liquid($LSF_6$) insulation is higher than high-pressurize $SF_6$ gas. The VB of the I-Air decreases as the temperature drops and the VB also drops. It is considered that the results of this paper are fundamental data for the electric insulation design of superconductor and cryogenic equipment that will be studied and developed in the future.

The Breakdown Characteristics of $SF_6$ and Imitation-Air ($SF_6$와 제조공기의 절연특성 비교 연구)

  • Choi, Eun-Hyuck;Park, He-Rie;Do, Yeong-Hoei;Choi, Young-Kil;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.335-338
    • /
    • 2008
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability are being required Also we request urgently change a $SF_6$ for an environment friendly gas insulation material. In this paper the experiments of breakdown characteristics by pressure and gap change of Imitation-Air in model GIS(Gas Insulated Switchgear) were described. Also assess of breakdown characteristics about Imitation-Air and $SF_6$. It is considered in this paper that the results are fundamental data for electric insulation design of Distribution Power Facilities which will be studied and developed in the future.

  • PDF

Breakdown Characteristics for Imitation Air and $SF_6$ with Pressure Variation under Uniform and Non-Uniform Field (평등/불평등 전계하에서 제조공기(I-Air)와 $SF_6$에 대한 압력별 절연파괴특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Jang, Seung-Ho;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.259-262
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79(%) : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using uniform(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage($V_B$) by each P different d.

  • PDF

A Comparision of the Breakdown Characteristics for $SF_6$ and I-Air based on Temperature variations (온도변화에 따른 $SF_6$와 I-Air의 절연파괴특성 비교)

  • Park, He-Rie;Kim, Do-Seok;Lee, Sang-Ho;Woo, Sung-Hun;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.235-237
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of l-Air(Imitation Air, $N_2:O_2=79:21$) and $SF_6$ gas based on temperature variations in experimental GIS model by applying negative DC voltage. The breakdown charcteristics were compared with gas pressures and each gas already entered in GIS model. The characteristics of l-Air and $SF_6$ were different in specific temperature range that $SF_6$ gas was being liquefied. The breakdown voltages of $SF_6$ were more higher than l-Air except for 4[atm] at $-10{\sim}0[^{\circ}C]$.

  • PDF

Breakdown Characteristics According to the Type & Gap of Rod-electrodes Using Imitation Air (제조공기를 이용한 봉전극의 형상 및 갭길이에 따른 절연파괴특성)

  • Lee, Jung-Keun;Lee, Su-Hyoung;Ahn, In-Seok;Jang, Jun-Oh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.19-23
    • /
    • 2014
  • In this paper the experiments of breakdown characteristics of rod-electrodes by pressure and gap change of imitation-air were described. The results are fundamental data for electric insulation design of distribution power facilities which will be studied and developed in the future. And we could make an environment friendly gas insulation material with mataining dielectric strength by imitation air which generates a lower lever of the global warming effect.

The Comparisons of the Surface Flashover Characteristics at $SF_6$ and the various insulation media. ($SF_6$와 이종절연재의 연면방전 특성 비교)

  • Lee, Jung-Hwan;Park, He-Rie;Park, Sung-Gyu;Choi, Young-Kil;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1400_1401
    • /
    • 2009
  • In this paper describes the comparisons of the surface flashover characteristics according to the change of the insulation media by experimental GIS(Gas Insulated Switchgear) chamber in accordance with change of pressure(P) and electrode distance(d). The using insulation medias are $SF_6$, Dry-Air, I-Air(Imitation Air, $N_2$ : $O_2$ = 79[%] : 21[%]), $N_2:O_2$ mixture gas and pure $N_2$. In this study, in order to compare the properties $SF_6$ and order insulation gas, we investigated the properties of the various insulation media with a knife to knife electrode under ac high voltage application. The gas pressure was changed from 1 to 5[atm]. as a result, it was found that dielectric strength is $SF_6$ > I-Air > Dry-Air and the best environmental preservation gas is Dry-Air.

  • PDF

Breakdown Characteristics of Imitation Air under Non-Uniform Fields (불평등 전계하의 제조공기(I-Air)에 대한 절연파괴 특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Yoon, Dae-Hee;Jang, Seung-Ho;Kim, Jung-Bae;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.385-388
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using non-uniform fields(Needle--Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

Breakdown Characteristics of Imitation Air under Uniform Fields and Non-Uniform (평등/불평등 전계 하에서의 제조공기(I-Air) 절연파괴특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Kim, Jung-Bae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1424-1425
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using niform fields(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

Dielectric Strength for Imitation Air with Pressure Variation under Uniform and Non-Uniform Fields (평등/불평등 전계하의 제조공기(I-Air)에 대한 압력별 절연파괴강도 특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Lee, Sang-Ho;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.263-266
    • /
    • 2007
  • In this paper approves (AC and DC) high voltage by experimental GIS(Gas Insulated Switchgear) chamber and (AC and DC) power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at (AC and DC) high voltage of Imitation I-Air, $N_2$ : $O_2$ = 79(%) : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's Dielectric Strength using uniform and non-uniform fields(sphere-sphere and Needle-Plane electrode) and studied relations dielectric strength($V_D$) by each P different d.

  • PDF