• Title/Summary/Keyword: Imaging Systems

Search Result 1,167, Processing Time 0.033 seconds

Image Analysis for Detection of Defects of BGA by Using X-ray Imaging

  • Sumimoto, Tetsuhiro;Maruyama, Toshinori;Azuma, Yoshiru;Goto, Sachiko;Mondou, Munehiro;furukwa, Noboru;Okada, Saburo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.87.5-87
    • /
    • 2002
  • . A high peak power demand at substations will result under This paper deals with the detection of defects at BGA solder joints in PC boards by using X-ray Imaging. . To improve a cost performance and reliability of PC boards, an inspection of BGA is required in the surface mount process. . Contents 2 We attempt to detect the characteristic of the solder bridges based on an image analysis.

  • PDF

MR Technology Beyond 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.109-111
    • /
    • 2003
  • Compared to the present clinical field strengths, MR at 47 and above promises to improve anatomic imaging quality by factors, and to bring metabolic and functional imaging to the forefront of research and diagnostic modalities. While human bore sized magnets as high as 9.4T are now installed, realization of the potential benefit of these magnets will require more of the MR system than a simple field, frequency or power scaling from technologies used at lower fields. New constraints on the high field MR studies, both physical and physiological, will require new technical developments to be considered for the highest field systems.

  • PDF

MRI의 현황과 전망

  • 전희국
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.125-130
    • /
    • 1988
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of $0.1^{\circ}C$ under the spatial resolution of lmrad, the image matrix size of $256 {\times} 240, $ and tile imaging time of 4 seconds.

  • PDF

Impedance Imaging of Binary-Mixture Systems with Regularized Newton-Raphson Method

  • Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.183-187
    • /
    • 2001
  • Impedance imaging for binary mixture is a kind of nonlinear inverse problem, which is usually solved iteratively by the Newton-Raphson method. Then, the ill-posedness of Hessian matrix often requires the use of a regularization method to stabilize the solution. In this study, the Levenberg-Marquredt regularization method is introduced for the binary-mixture system with various resistivity contrasts (1:2∼1:1000). Several mixture distribution are tested and the results show that the Newton-Raphson iteration combined with the Levenberg-Marquardt regularization can reconstruct reasonably good images.

  • PDF

Study on Measurement Errors due to Attenuation in Plannar Image technique (평면 이미지 기법에서 감쇠로 인한 측정 오차에 대한 연구)

  • Jeon, J.Y.;Kim, D.J.;Koh, H.S.;Yoon, Y.B.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.24-30
    • /
    • 2002
  • In the analysis of the mass distribution and SMD(Sauter Mean Diameter), planar laser imaging technique is a convenient and useful one when compared to the mechanical pattemator or PDPA (Phase Doppler Particle Analyzer). But recorded signals at cameras and intensity of laser are distorted by attenuation. Using experimental datum and assumptions, we study measurement errors due to attenuation in plannar image technique.

  • PDF

Comparison and consideration of general hospital with small-medium hospital PACS system problem (종합병원과 중$\cdot$소병원 방사선과의 PACS system 비교와 발생하는 문제점에 대한 고찰)

  • Kim Hyun;Cho Jongmin;Hwang Sangsu
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.222-228
    • /
    • 2001
  • Ⅰ. Purpose : The development of new imaging techniques and the increasing proportion of medical imaging modalities that generate images in digital form has naturally lead to the development of digital image management systems. Many people would agree that

  • PDF

Development of an Imaging Radiometer System at W-band (W 대역 영상라디오미터 시스템 개발)

  • Jung, Min-Kyoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1133-1138
    • /
    • 2010
  • We have developed an imaging radiometer system at W-band. The system consists of lens, reflector, 30-ch receiver array, scanner, and signal processor. One receiver consists of a dielectric rod antenna, a balun, LNA(low noise amplifier) and a detector. The system configuration requirements are described. Finally, we represent radiometer images to obtain through clouds, smoke, dust, and other obstructions which render visible and IR systems ineffective.

Review of Neurosurgical Fluorescence Imaging Systems for Clinical Application

  • Kim, Hong Rae;Lee, Hyun Min;Yoo, Heon;Lee, Seung Hoon;Kim, Kwang Gi
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.305-313
    • /
    • 2016
  • A number of fluorescence imaging techniques for use in the surgical removal of glioma have been developed over the course of the long history of neurosurgery. Various biomarkers, biochemical agents, and detection systems for glioma have also been developed. This review focuses on 5-aminolevulinic acid (5-ALA), which is used to detect glioma. Numerous forms of fluorescence-guided surgery use 5-ALA, which is helpful to the surgeon. The surgical microscope system is the observational method generally used with 5-ALA, while the loupe, endoscope, and exoscope are simpler alternatives. A system is needed for minimal resection and other issues that arise during neurosurgery. Such an enhanced system should be able to detect low-grade tumors and provide information on microinvasive diseases, resulting in an improved survival rate and better surgical skills. Development of systems that fulfill certain needs would help protect the brain function of the patient and broaden the use of such systems in neurosurgery.

Fabrication of Multicomponent Protein Microarrays with Microfluidic Devices of Poly(dimethylsiloxane)

  • Jeon, Se-Hoon;Kim, Ui-Seong;Jeon, Won-Jin;Shin, Chee-Burm;Hong, Su-Rin;Choi, In-Hee;Lee, Su-Seung;Yi, Jong-Heop
    • Macromolecular Research
    • /
    • v.17 no.3
    • /
    • pp.192-196
    • /
    • 2009
  • Recently, the multi-screening of target materials has been made possible by the development of the surface plasmon resonance (SPR) imaging method. To adapt this method to biochemical analysis, the multi-patterning technology of protein microarrays is required. Among the different methods of fabricating protein microarrays, the microfluidic platform was selected due to its various advantages over other techniques. Microfluidic devices were designed and fabricated with polydimethylsiloxane (PDMS) by the replica molding method. These devices were designed to operate using only capillary force, without the need for additional flow control equipment. With these devices, multiple protein-patterned sensor surfaces were made, to support the two-dimensional detection of various protein-protein interactions with SPR. The fabrication technique of protein microarrays can be applied not only to SPR imaging, but also to other biochemical analyses.

Brain-wave Analysis using fMRI, TRS and EEG for Human Emotion Recognition (fMRI와 TRS와 EEG 를 이용한 뇌파분석을 통한 사람의 감정 인식)

  • Kim, Ho-Duck;Sim, Kwee-Bo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.7-10
    • /
    • 2007
  • 많은 과학자들은 인간의 사고를 functional Magnetic Resonance Imaging (fMRI), Time Resolved Spectroscopy(TRS), Electroencephalography(EEG)등을 이용해서 두뇌 활동 영역을 연구하고 있다. 주로 의학 분야와 심리학의 영역에서 두뇌의 활동을 연구하여 간질이나 발작을 알아내고 거짓말 탐지 분야에서도 사용된다. 본 논문에서는 사람의 두뇌활동을 측정하여 인간의 감정을 인식하는 연구에 중점을 두었다. 특히 fMRI와 TRS 그리고 EEG를 이용해서 사람의 두뇌활동을 측정하는 연구를 하였다. 많은 연구자들이 한 가지 측정 장치만을 사용하여서 측정하거나 fMRI와 EEG를 동시에 측정하는 연구를 진행하고 있다. 현재에는 단순히 두뇌의 활동을 측정하거나 측정시 발생하는 잡음들을 제거하는 연구들에 중점을 두고 진행되고 있다. 본 연구에서는 fMRI와 TRS를 동시에 측정하여 얻은 두뇌 활동 데이터를 가지고 감정에 따른 활동영역의 EEG신호를 측정하였다. EEG 신호분석에 있어서 기존의 뇌파만을 가지고 특정을 찾아내는 것을 넘어서 각각의 채널에서 기록되는 뇌파의 파형을 주파수에 따라서 분류하고 정확한 측정을 위해 낮은 주파수를 제거하고 연구자가 필요한 부분의 뇌파를 분석하였다.

  • PDF