• Title/Summary/Keyword: Imaging Optics

Search Result 399, Processing Time 0.025 seconds

Tolerance analysis of Multi-Configurative Microscopic System for Inspecting the Wire-Bonding Status of Semiconductor Chips (반도체 와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차분석)

  • Ryu, Jae-Myung;Kim, Jae-Bum;Kang, Geon-Mo;Jung, Jin-Ho;Baek, Seung-Sun;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.149-158
    • /
    • 2006
  • We have analyzed various tolerances of the multi-configurative microscopic system for inspecting the wire-bonding of a reed frame by using the Gaussian bracket method and the equivalent lens method. The tolerances for the curvature and the thickness, which are axial symmetric tolerances, are given by varying the back focal length within a fecal depth under diffraction-limited conditions. Moreover, by using the trial and error method, the axial non-symmetric tolerances for decenter and tilt are established by assigning the 5% variation of MTF(modulation transfer function) at the spatial frequency of 50 lp/mm and at the field angle of 0.7 field. As the tolerances with the most probable distribution are distributed within the range of the decay rate of less than 5% independent of the probability distribution of tolerances, we can achieve completely the desired design performances of the multi-configurative microscopic system by using the various ranges of these tolerances.

Molding and Evaluation of Ultra-Precision Chalcogenide-Glass Lens for Thermal Imaging Camera Using Thermal Deformation Compensation (열변형 보정을 통한 열화상카메라용 초정밀 칼코지나이드 유리렌즈 몰드성형 및 특성 평가)

  • Cha, Du Hwan;Kim, Jeong-Ho;Kim, Hye-Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.91-96
    • /
    • 2014
  • Aspheric lenses used in the thermal imaging are typically fabricated using expensive single-crystal materials (Ge and ZnS, etc.) by the costly single point diamond turning (SPDT) process. As a potential solution to reduce cost, compression molding method using chalcogenide glass has been attracted to fabricate IR optic. Thermal deformation of a molded lens should be compensated to fabricate chalcogenide aspheric lens with form accuracy of the submicron-order. The thermal deformation phenomenon of molded lens was analyzed ant then compensation using mold iteration process is followed to fabricate the high accuracy optic. Consequently, it is obvious that compensation of thermal deformation is critical and useful enough to be adopted to fabricate the lens by molding method.

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

Dynamic Modulation Transfer Function Analysis of Images Blurred by Sinusoidal Vibration

  • Du, Yanlu;Ding, Yalin;Xu, Yongsen;Sun, Chongshang
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.762-769
    • /
    • 2016
  • The dynamic modulation transfer function (MTF) for image degradation caused by sinusoidal vibration is formulated based on a Bessel function of the first kind. The presented method makes it possible to obtain an analytical MTF expression derived for arbitrary frequency sinusoidal vibration. The error obtained by the use of finite order sum approximations instead of infinite sums is investigated in detail. Dynamic MTF exhibits a stronger random behavior for low frequency vibration than high frequency vibration. The calculated MTFs agree well with the measured MTFs with the slant edge method in imaging experiments. With the proposed formula, allowable amplitudes of any frequency vibration are easily calculated. This is practical for the analysis and design of the line-of-sight stabilization system in the remote sensing camera.

Non-imaging Optical Design of a Measurement Probe for LCD Display Used in a Color Analyzer (LCD 디스플레이용 색채계 렌즈에 관한 비결상 광학설계)

  • Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.5
    • /
    • pp.239-244
    • /
    • 2011
  • We introduce Gaussian (or paraxial) optics that can be successfully applied to design, for use in a color analyzer, a non-imaging optical system on a measurement probe for LCD display. The color analyzer is used to decompose colored lights leaving from some measurement area on the LCD display to red, green, and blue. The color analyzer must include a condenser lens whose purpose is to gather colored lights to illuminate a small area on the sensor. In order to satisfy a reduction ratio between the measurement area and the sensing area with a non-imaging condition, a condenser lens is analytically treated by means of Gaussian optics so that good understanding of the non-imaging condenser lens is achieved as a good design is derived. As a result, the technique shows the necessity of analytical treatment in contrast to the design approach using only commercial software such as CODE-V, Light-Tools, and others. Of course, CODE V and Light-Tools are also utilized in this paper to confirm and complete the Gaussian optical design.

Application of Terahertz Spectroscopy and Imaging in the Diagnosis of Prostate Cancer

  • Zhang, Ping;Zhong, Shuncong;Zhang, Junxi;Ding, Jian;Liu, Zhenxiang;Huang, Yi;Zhou, Ning;Nsengiyumva, Walter;Zhang, Tianfu
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.31-43
    • /
    • 2020
  • The feasibility of the application of terahertz electromagnetic waves in the diagnosis of prostate cancer was examined. Four samples of incomplete cancerous prostatic paraffin-embedded tissues were examined using terahertz spectral imaging (TPI) system and the results obtained by comparing the absorption coefficient and refractive index of prostate tumor, normal prostate tissue and smooth muscle from one of the paraffin tissue masses examined were reported. Three hundred and sixty cases of absorption coefficients from one of the paraffin tissues examined were used as raw data to classify these three tissues using the Principal Component Analysis (PCA) and Least Squares Support Vector Machine (LS-SVM). An excellent classification with an accuracy of 92.22% in the prediction set was achieved. Using the distribution information of THz reflection signal intensity from sample surface and absorption coefficient of the sample, an attempt was made to use the TPI system to identify the boundaries of the different tissues involved (prostate tumors, normal and smooth muscles). The location of three identified regions in the terahertz images (frequency domain slice absorption coefficient imaging, 1.2 THz) were compared with those obtained from the histopathologic examination. The tissue tumor region had a distinctively visible color and could well be distinguished from other tissue regions in terahertz images. Results indicate that a THz spectroscopy imaging system can be efficiently used in conjunction with the proposed advanced computer-based mathematical analysis method to identify tumor regions in the paraffin tissue mass of prostate cancer.

Measurement of the Modulation Transfer Function of Infrared Imaging System by Modified Slant Edge Method

  • Li, Hang;Yan, Changxiang;Shao, Jianbing
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.381-388
    • /
    • 2016
  • The performance of a staring infrared imaging system can be characterized based on estimating the modulation transfer function (MTF). The slant edge method is a widely used MTF estimation method, which can effectively solve the aliasing problem caused by the discrete undersampling of the infrared focal plane array. However, the traditional slant edge method has some limitations such as the low precision of the edge angle extraction and using the approximate function to fit the edge spread function (ESF), which affects the accuracy of the MTF estimation. In this paper, we propose a modified slant edge method, including an edge angle extraction method that can improve the precision of the edge angle extraction and an ESF fitting algorithm which is based on the transfer function model of the imaging system, to enhance the accuracy of the MTF estimation. This modified slant edge method presents higher estimation accuracy and better immunity to noise and edge angle than other traditional methods, which is demonstrated by the simulation and application experiments operated in our study.

Optimum parameters of 3D integral imaging system (3차원 집적 영상 시스템의 최적 파라미터)

  • Cho, Myungjin;Lee, Byonggook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1019-1022
    • /
    • 2012
  • Integral imaging is a promising technology for 3D imaging and display. Many parameters affect the performance of 3D integral imaging systems. Enhanced system performance is acquired by optimization of these system parameters with respect to defined performance metrics. In this paper, we present an approach to optimize the performance of 3D integral imaging system in terms of performance metrics under fixed resource constraints. In this analysis, system parameters such as lens numerical aperture, pitch between image sensors, the number of image sensors, the pixel size, and the number of pixels are determined to optimize performance metrics. Wave optics is utilized to describe the imaging process.

  • PDF

Laser Illuminated Multi-viewer 3D Displays

  • Sexton, Ian;Bates, Richard;Lee, Wing;Surman, Phil;Hopf, Klaus;Neumann, Frank;Corbett, Alex;Buckley, Edward
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1423-1426
    • /
    • 2008
  • This paper describes current work regarding two EC funded projects, MUTED and HELIUM3D whose objective is to produce an autostereoscopic display system which is well suited to domestic television applications. Both of these projects have common roots in a previous EC funded project (ATTEST) and both employ laser illumination and viewer head tracking.

  • PDF