• Title/Summary/Keyword: Imaging Method

Search Result 3,043, Processing Time 0.03 seconds

Analysis of 3D integral imaging systems under fixed resource constraints (제안된 리소스에서 3D 집적 영상 시스템의 분석 기법)

  • Shin, Donghak;Hong, Seok-Min;Lee, Byung-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1012-1014
    • /
    • 2012
  • Integral imaging is considered as a next-generation 3D display which can display 3d imaging in space using lens array. The performance of integral imaging systems depends on several factors including display panel, lens array, imaging devices and so on. In this paper, we develop a unifying framework to evaluate the resolution of integral imaging systems under fixed resource constraints. The proposed framework enables one to optimize the system performance. To show the feasibility of the proposed method, we carry out Monte Carlo simulations based on this framework and present the results.

  • PDF

Synthetic approaches toward [18F]Fluoromisonidazole as a hypoxia imaging maker

  • Kwon, Young-Do;Lim, Seok Tae;Jeong, Hwan-Jeong;Sohn, Myung-Hee;Kim, Hee-Kwon
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Hypoxia has been shown in many tumors because of a reduced oxygen condition. A useful approach to detect hypoxia is to use molecular imaging. Positron emission tomography (PET), one of the biomedical molecular imaging tools, is the most common non-invasive technique for providing information about physiological and biological events such as diseases. In order to use the PET technique for healthcare, promising molecular probes such as PET tracers required. [$^{18}F$]Fluoromisonidazole ([$^{18}F$]FMISO) is the most widely used in PET tracers for hypoxia. In this review, major developments of the synthetic method of [$^{18}F$]FMISO are discussed.

Integral Imaging Monitors with an Enlarged Viewing Angle

  • Dorado, Adria;Saavedra, Genaro;Sola-Pikabea, Jorge;Martinez-Corral, Manuel
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.2
    • /
    • pp.132-138
    • /
    • 2015
  • Enlarging the horizontal viewing angle is an important feature of integral imaging monitors. Thus far, the horizontal viewing angle has been enlarged in different ways, such as by changing the size of the elemental images or by tilting the lens array in the capture and reconstruction stages. However, these methods are limited by the microlenses used in the capture stage and by the fact that the images obtained cannot be easily projected into different displays. In this study, we upgrade our previously reported method, called SPOC 2.0. In particular, our new approach, which can be called SPOC 2.1, enlarges the viewing angle by increasing the density of the elemental images in the horizontal direction and by an appropriate application of our transformation and reshape algorithm. To illustrate our approach, we have calculated some high-viewing angle elemental images and displayed them on an integral imaging monitor.

Medical Ultrasonic Elasticity Imaging Techniques (의료용 초음파탄성영상법)

  • Jeong, Mok-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.573-584
    • /
    • 2012
  • Breast and prostate tumors or cancers tend to be stiffer than the surrounding normal tissue. However, the difference in echogenicity between cancerous and normal tissues is not clearly distinguishable in ultrasound B-mode imaging. Thus, imaging the stiffness contrast between the two different tissue types helps to diagnose lesions quantitatively, and such a method of imaging the elasticity of human tissue is termed ultrasound elasticity imaging. Recently, elasticity imaging has become an effective complementary diagnostic modality along with ultrasound B-mode imaging. This paper presents various elasticity imaging methods that have been reported up to now and describes their characteristics and principles of operation.

Development and Packaging of Multi-channel Imaging Module for Near-infrared Fluorescence Imaging System (근적외선 형광 영상 시스템용 다채널 영상 모듈 개발 및 패키징)

  • Kim, Taehoon;Seo, Kyung Hwan;Lee, Hak Keun;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.59-64
    • /
    • 2019
  • In this paper, we introduced a near-infrared multi-channel fluorescence imaging system and analyzed the effects of measurements variables such as exposure time, working distance and intensity of excitation light. Fluorescence signal is increased as exposure time becomes longer, excitation light intensity increases or working distance becomes smaller. Furthermore, the proper composition of optical filters and precise packaging of the imaging modules prevent the increase of background signal. Thus, we confirmed an increase in SBR. Based on the result of this research, we proposed a method to use a multi-channel fluorescence imaging system.

Three-Dimensional Automatic Target Recognition System Based on Optical Integral Imaging Reconstruction

  • Lee, Min-Chul;Inoue, Kotaro;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • In this paper, we present a three-dimensional (3-D) automatic target recognition system based on optical integral imaging reconstruction. In integral imaging, elemental images of the reference and target 3-D objects are obtained through a lenslet array or a camera array. Then, reconstructed 3-D images at various reconstruction depths can be optically generated on the output plane by back-projecting these elemental images onto a display panel. 3-D automatic target recognition can be implemented using computational integral imaging reconstruction and digital nonlinear correlation filters. However, these methods require non-trivial computation time for reconstruction and recognition. Instead, we implement 3-D automatic target recognition using optical cross-correlation between the reconstructed 3-D reference and target images at the same reconstruction depth. Our method depends on an all-optical structure to realize a real-time 3-D automatic target recognition system. In addition, we use a nonlinear correlation filter to improve recognition performance. To prove our proposed method, we carry out the optical experiments and report recognition results.

In vivo Monitoring of the Incorporation of Chemicals into Cucumber end Rice Leaves by Chlorophyll Fluorescence Imaging

  • Kim, Jin-Hong;Jung, Ji-Eun;Lee, Choon-Hwan
    • Journal of Plant Biotechnology
    • /
    • v.4 no.4
    • /
    • pp.171-178
    • /
    • 2002
  • Chlorophyll (Chl) fluorescence imaging was used to investigate the effectiveness of in vivo incorporation methods for two chemicals, 3-(3',4'-dichlorophenyl)-1,1-dimethylurea (DCMU) and methyl viologen (MV) in rice, a monocot, and cucumber, a dicot, leaves. four different methods (vacuum infiltration, floating, transpiration-aided incorporation through petiole and spraying) were compared, and $F_i$ and $F_v$/$F_m$ were chosen for the imaging of the DCMU- and MV-treated leaves, respectively. The effects of the chemicals in plants were generally heterogeneous over the whole leaf area. Moreover, the effectiveness of the treatment of a chemical in plant leaves was dependent on chemical species, plant species, concentration of the chemical, the treatment method, the duration of the treatment, the existence of light and detergent, etc. In conclusion, we suggest that to achieve the proposed effects of chemicals in plants for an actual experiment, these factors must be considered before the chemical treatment, and the best method for the treatment of the chemicals tested was floating and vacuum infiltration in the dicot and the monocot leaves, respectively, as drawn from Chl fluorescence imaging analysis.

SPATIO-SPECTRAL MAXIMUM ENTROPY METHOD: II. SOLAR MICROWAVE IMAGING SPECTROSCOPY

  • Bong, Su-Chan;Lee, Jeong-Woo;Gary Dale E.;Yun Hong-Sik;Chae Jong-Chul
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.4
    • /
    • pp.445-462
    • /
    • 2005
  • In a companion paper, we have presented so-called Spatio-Spectral Maximum Entropy Method (SSMEM) particularly designed for Fourier-Transform imaging over a wide spectral range. The SSMEM allows simultaneous acquisition of both spectral and spatial information and we consider it most suitable for imaging spectroscopy of solar microwave emission. In this paper, we run the SSMEM for a realistic model of solar microwave radiation and a model array resembling the Owens Valley Solar Array in order to identify and resolve possible issues in the application of the SSMEM to solar microwave imaging spectroscopy. We mainly concern ourselves with issues as to how the frequency dependent noise in the data and frequency-dependent variations of source size and background flux will affect the result of imaging spectroscopy under the SSMEM. We also test the capability of the SSMEM against other conventional techniques, CLEAN and MEM.

Research status for long term half-life PET radioisotopes in KIRAMS

  • Kim, Jung Young;Park, Hyun;Chun, Kwon Soo;An, Gwang Il
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • It is essential use of long term half life radioisotopes for positron emission tomography (PET) imaging study of biopharmaceuticals because most of biopharmaceuticals have long biological half-life. Some representative isotopes are $^{124}I$, $^{64}Cu$, $^{89}Zr$ and so on. These PET radioisotopes and their radiopharmaceuticals have recently received growing interest because of long half life and good imaging properties. Furthermore, $^{64}Cu$ and $^{89}Zr$ can be used in a number of radiopharmaceuticals due to its ease of conjugation to peptides and antibodies using the proper chelator. In recent years, since $^{124}I$ was first developed in 2005, we have been studied to develop an efficient method and procedure for producing these radioisotopes, and we have made considerable progress in production of long term half life radioisotopes. This review introduces the general production system, purification procedure, and several advances on targeting method for $^{124}I$ and $^{64}Cu$ in KIRAMS.

Orthoscopic real image reconstruction in integral imaging by modifying coordinate of elemental image (집적영상에서 요소영상의 좌표변환을 이용한 정치실영상 구현)

  • Jang, Jae-young;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1646-1652
    • /
    • 2015
  • In this paper, we propose a depth conversion method for orthoscopic real image reconstruction in integral imaging. Pseudoscopic image has been regarded a problem in conventional integral imaging. the depth of reconstructed image is depending on a coordinate of an elemental image. The conversion from pseudoscopic to orthoscopic may be possible by analysing the geometrical relation between pickup and reconstruction system of elemental image. The feasibility of the proposed method has been confirmed through preliminary experiments as well as ray optical analysis.