• Title/Summary/Keyword: Image-guided

Search Result 374, Processing Time 0.032 seconds

The evaluation of image-guided catheter drainage in pleural effusion and empyema (흉수 및 농흉에서의 영상유도하 도관배액술의 유용성 평가)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.403-409
    • /
    • 1996
  • Background : Pleural fluid collections may pose a difficult therapeutic problem. Complete drainage of complicated effusions or empyemas and reexpansion of atelectatic lung are important in obtaining a satisfactory clinical outcome. The usual approach to the diagnosis and treatment of patients with pleural effusion and empyema has been with needle thoracentesis and chest tube drainage. With chest tube drainage, technical difficulties and failures may occur as a result of improper tube drainage, particularly when there is a loculation or multiple and inaccesible collections. Fluoroscopic or sonographic guidance facilitates the proper tube insertion and drainage. Method : Twenty eight patients were required for tube drainage due to pleural fluid collections between January 1994 to February 1996. The author compared the results of drainage under applying each different method between blind chest tube insertion and image guided catheter insertion. Results : The conventional blind chest tube group comprised 14 patients; 6 empyema, 6 tuberculous effusion, and 2 parapneumonic effusion. The image guided catheter group of smaller french were composed of 14 patients; 2 empyema, 6 tuberculous effusion, 5 parapneumonic effusion, and 1 effusion of undetermined origin. Radiologic improvement with successful drainage was noticed in 79% with the blind chest tube group, whereas in 93% with the image guided catheter group. The complication with the latter method was unremarkable. Conclusion : Image guided catheter drainage was safe and highly successful in treating patients, not only with complicated effusion also with loculated empyema. Image guided catheter drainage offers an alternative in patients in whom closed drainage is required as the initial treatment.

  • PDF

Stereo Matching Algorithm Based on Fast Guided Image Filtering for 3-Dimensional Video Service (3차원 비디오 서비스를 위한 고속 유도 영상 필터링 기반 스테레오 매칭 알고리즘)

  • Hong, Gwang-Soo;Kim, Byung-Gyu
    • Journal of Digital Contents Society
    • /
    • v.17 no.6
    • /
    • pp.523-529
    • /
    • 2016
  • Stereo matching algorithm is an essential part in computer vision and photography. Accuracy and computational complexity are challenges of stereo matching algorithm. Much research has been devoted to stereo matching based on cost volume filtering of matching costs. Local stereo matching based guided image filtering (GIF) has a computational complexity of O(N), but is still not enough to provide real-time 3-dimensional (3-D) video services. The proposed algorithm concentrates reduction of computational complexity using the concept of fast guided image filter, which increase the speed up to $O(N/\small{s}^2)$ with a sub-sampling ratio $\small{s}$. Experimental results indicated that the proposed algorithm achieves effective local stereo matching as well as a fast execution time for 3-D video service.

Hit Rate Prediction Algorithm for Laser Guided Bombs Using Image Processing (영상처리 기술을 활용한 레이저 유도폭탄 명중률 예측 알고리즘)

  • Ahn, Younghwan;Lee, Sanghoon
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.3
    • /
    • pp.247-256
    • /
    • 2015
  • Since the Gulf War, air power has played a key role. However, the effect of high-tech weapons, such as laser-guided bombs and electronic optical equipment, drops significantly if they do not match the weather conditions. So, aircraft that are assigned to carry laser-guided bombs must replace these munitions during bad weather conditions. But, there are no objective criteria for when weapons should be replaced. Therefore, in this paper, we propose an algorithm to predict the hit rate of laser-guided bombs using cloud image processing. In order to verify the accuracy of the algorithm, we applied the weather conditions that may affect laser-guided bombs to simulated flight equipment and executed simulated weapon release, then collected and analyzed data. Cloud images appropriate to the weather conditions were developed, and applied to the algorithm. We confirmed that the algorithm can accurately predict the hit rate of laser-guided bombs in most weather conditions.

Noise Removal in Magnetic Resonance Images based on Non-Local Means and Guided Image Filtering (비 지역적 평균과 유도 영상 필터링에 기반한 자기 공명 영상의 잡음 제거)

  • Mahmood, Muhammad Tariq;Choi, Young Kyu
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.11
    • /
    • pp.573-578
    • /
    • 2014
  • In this letter, we propose a noise reduction method for use in magnetic resonance images that is based on non-local mean and guided image filters. Our method consists of two phases. In the first phase, the guidance image is obtained from a noisy image by using an adaptive non-local mean filter. The spread of the kernel is adaptively by controlled by implementing the concept of edgeness. In the second phase, the noisy images and the guidance images are provided to the guided image filter as input in order to produce a noise-free image. The improved performance of the proposed method is investigated by conducting experiments on standard datasets that contain magnetic resonance images. The results show that the proposed scheme is superior over the existing approaches.

Image-guided radiation therapy in lymphoma management

  • Eng, Tony;Ha, Chul S.
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.161-171
    • /
    • 2015
  • Image-guided radiation therapy (IGRT) is a process of incorporating imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), Positron emission tomography (PET), and ultrasound (US) during radiation therapy (RT) to improve treatment accuracy. It allows real-time or near real-time visualization of anatomical information to ensure that the target is in its position as planned. In addition, changes in tumor volume and location due to organ motion during treatment can be also compensated. IGRT has been gaining popularity and acceptance rapidly in RT over the past 10 years, and many published data have been reported on prostate, bladder, head and neck, and gastrointestinal cancers. However, the role of IGRT in lymphoma management is not well defined as there are only very limited published data currently available. The scope of this paper is to review the current use of IGRT in the management of lymphoma. The technical and clinical aspects of IGRT, lymphoma imaging studies, the current role of IGRT in lymphoma management and future directions will be discussed.

Dosimetric Verification for Primary Focal Hypermetabolism of Nasopharyngeal Carcinoma Patients Treated with Dynamic Intensity-modulated Radiation Therapy

  • Xin, Yong;Wang, Jia-Yang;Li, Liang;Tang, Tian-You;Liu, Gui-Hong;Wang, Jian-She;Xu, Yu-Mei;Chen, Yong;Zhang, Long-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.985-989
    • /
    • 2012
  • Objective: To make sure the feasibility with $^{18F}FDG$ PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Methods: Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and $^{18F}FDG$ PET/CT). The dose distributions of the various regional were realized by SMART. Results: The absolute mean errors of interest area were $2.39%{\pm}0.66$ using 0.6cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Conclusions: Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

A Comprehensive and Practical Image Enhancement Method

  • Wu, Fanglong;Liu, Cuiyin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.10
    • /
    • pp.5112-5129
    • /
    • 2019
  • Image enhancement is a challenging problem in the field of image processing, especially low-light color images enhancement. This paper proposed a robust and comprehensive enhancement method based several points. First, the idea of bright channel is introduced to estimate the illumination map which is used to attain the enhancing result with Retinex model, and the color constancy is keep as well. Second, in order eliminate the illumination offsets wrongly estimated, morphological closing operation is used to modify the initial estimating illumination. Furthermore, in order to avoid fabricating edges, enlarged noises and over-smoothed visual features appearing in enhancing result, a multi-scale closing operation is used. At last, in order to avoiding the haloes and artifacts presented in enhancing result caused by gradient information lost in previous step, guided filtering is introduced to deal with previous result with guided image is initial bright channel. The proposed method can get good illumination map, and attain very effective enhancing results, including dark area is enhanced with more visual features, color natural and constancy, avoiding artifacts and over-enhanced, and eliminating Incorrect light offsets.

Interpretation of Image-Guided Biopsy Results and Assessment (영상유도하 조직검사의 해석과 판정)

  • Su Min Ha;Jung Min Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.361-371
    • /
    • 2023
  • The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.

Implementation of Virtual Instrumentation based Realtime Vision Guided Autopilot System and Onboard Flight Test using Rotory UAV (가상계측기반 실시간 영상유도 자동비행 시스템 구현 및 무인 로터기를 이용한 비행시험)

  • Lee, Byoung-Jin;Yun, Suk-Chang;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.9
    • /
    • pp.878-886
    • /
    • 2012
  • This paper investigates the implementation and flight test of realtime vision guided autopilot system based on virtual instrumentation platform. A graphical design process via virtual instrumentation platform is fully used for the image processing, communication between systems, vehicle dynamics control, and vision coupled guidance algorithms. A significatnt ojective of the algorithm is to achieve an environment robust autopilot despite wind and an irregular image acquisition condition. For a robust vision guided path tracking and hovering performance, the flight path guidance logic is combined in a multi conditional basis with the position estimation algorithm coupled with the vehicle attitude dynamics. An onboard flight test equipped with the developed realtime vision guided autopilot system is done using the rotary UAV system with full attitude control capability. Outdoor flight test demonstrated that the designed vision guided autopilot system succeeded in UAV's hovering on top of ground target within about several meters under geenral windy environment.

An Adaptive Guided Filter for Performance Improvement of Aviation Image Fusion (항공 영상 융합의 성능 향상을 위한 적응 가이디드 필터)

  • Kim, Sun Young;Kang, Chang Ho;Park, Chan Gook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.407-415
    • /
    • 2016
  • In this paper, an aviation image fusion method is proposed for creating an informative fused image through gray scale images within noise. The proposed method is based on an adaptive guided filter which adjusts regulation parameter of the filter based on peak signal noise ratio (PSNR) in order to behave as an edge-preserving filtering property. Simulation results demonstrate that the proposed method preserves the edge information of the input image and reduces the noise effect while maintaining designed PSNR.