• Title/Summary/Keyword: Image technique

Search Result 5,858, Processing Time 0.043 seconds

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems (방출단층촬영 시스템을 위한 GPU 기반 반복적 기댓값 최대화 재구성 알고리즘 연구)

  • Ha, Woo-Seok;Kim, Soo-Mee;Park, Min-Jae;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.459-467
    • /
    • 2009
  • Purpose: The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Materials and Methods: Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. Results: The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 see, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 see, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. Conclusion: The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

A Study on Glass Mirror Trade and its Characteristics of Craft after Joseon Dynasty (조선 후기 유리거울의 수입과 공예품의 특징)

  • Park, Jinkyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.206-225
    • /
    • 2019
  • This paper examines the trade and development aspects of glass mirrors through the literature records of the Joseon Dynasty, and studies the characteristics of existing glass mirror crafts by referring to the terms and types shown in the literature. The glass mirror in the records had called western mirrors(西洋鏡, 洋鏡), glass mirrors(玻璃鏡, 玻瓈鏡), stone mirrors(石鏡), etc. Glass mirrors were imported mainly through trade with Russia and the Qing Dynasty since the 17th century and were banned from importation in the late Joseon Dynasty. These mirrors were something new that caused a great stirring in Joseon society in the 18th century, and in the 19th century, it grew larger as a commodity needed for everyday life, especially with trade with Japan. At that time, glass mirrors were used for various purposes, such as installing large glass at a store, which were not the standard mirror usage of confirming one's appearance. These mirrors surprised Koreans in Joseon who experienced them at Yanjing Liulichang(燕京 琉璃廠) in the 18th and 19th centuries. As a result, the demand for glass mirrors rapidly increased and quickly surpassed that of bronze mirrors. Consequentially, new crafts using glass mirrors instead of bronze mirrors in Joseon began to be produced and used after the 18th century. In particular, integrated flat boards of glass mirrors were developed as crafts used indoors. It was convenient to use the hair comb box, a long-time presence in Joseon society, with the bronze mirror. This kind of mirror remained apparent in various genre paintings, including the Taepyeong Seongsido(太平城市圖, 'A Thriving City in a Peaceful Era') collected the National Museum of Korea which reflect its populism of the times. Also, the Mirror Stand(鏡臺) used in the Qing Period was produced in Joseon, but there was a difference in the way of making the drawers and box shapes between two nations. On the other hand, the Face Mirror(面鏡) was made to look at the face. Various crafts made with the aesthetic sense of Joseon, such as the ox horn inlaying craft technique, were produced with auspicious designs. In the 19th century, glass mirrors were imported from European countries, such as France, Denmark, the Netherlands, and the United Kingdom, however after the end of the 19th century Japanese crafts were popular. Glass mirrors, which were popular in the Meiji and Taisho eras of Japan, were imported and also the Mirror Screen(鏡屛) using large glass mirrors were used. In particular, the mirror screen had developed wood furniture since the previous time, which were used for banquets and large spaces, such as the drawing room, and were imported from China and Japan. In addition, the western architectural effect of attaching a mirror to the wall was also attempted to adjust the brightness of the space and introduce another image and scenery in the mirror. This was done at Deoksugung Palace's Seokjojeon.

A STUDY OF INSERTION DEPTH OF GUTTA PERCHA CONES AFTER SHAPING BY NI-TI ROTARY FILES IN SIMULATED CANALS (레진모형 근관에서 Ni-Ti 파일로 근관성형 후 거타퍼챠콘의 근관내 삽입깊이에 대한 연구)

  • Cho, Hyun-Gu;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.550-558
    • /
    • 2007
  • The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25(n=10), .06 taper #25(n=10), ProTaper F2(n=10), HEROShaper .04 taper #25(n=10) and .06 taper #25(n=10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted(p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted(p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.

A Study on Proposal of Landscape Management Improvement on the Quantitative Analysis of National Parks (국립공원(國立公園) 자연경관(自然景觀)의 계량적(計量的) 분석(分析)을 통(通)한 경관관리(景觀管理) 개선방안(改善方案)에 관(關)한 연구)

  • Kim, Sei Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.1
    • /
    • pp.32-41
    • /
    • 1991
  • This study is focusted to the national park of Korean typical mountain Chi-ri, its visual resources of forests, and practiced inspectind course by way of hypothesis and tests, to show visual resource management objectively, and that of quantitative basic data. spatial image structure measured by Semantic Differential(S.D.) Scale was shown through factor analysis algorithm for the analyzing psychological amount and examined the flowing out of decisive factor and the objective importance related mutual factors by appling the measurement of visual quality. Also, it has been investigated the differences between the degrees of expectation which is used before and of satisfaction which is used, by appling instrumental expectation theory. And showed patterns of investigation area through factor analyzing algorithm. As a national Park, visual factors that have natural landscape harmonized forest, sky, surface of the water, curious stones and rocks, temples should be escalate their values affirmatively so as to be the scenery of pointed direction and enjoyable, and it is needs the techniques visual resource management and its controlling technique to make artificial structures more intentional planning and systemical setting. Manmade distinctive quality in the spatials that affect complementally or harmonizingly, should be received considering relations between the distifution and joining which in line with various visual presenting massive factors. More than that, it is needed united basic standard to the beauty of arrangements which contain visual continuity considered balance between nature and human work, simplicity of structural types, assimilation, emphasis, unification of different factors and pro rata.

  • PDF

Characterization of a new commercial strain 'Goni' by intra-specific hyphal anastomosis in Pleurotus ostreatus (계통간 교잡에 의한 백색느타리 품종 '고니'의 육성 및 그 특성)

  • Yoo, Young Bok;Lee, Sang Cheol;Kim, Eun Jung;Kong, Won Sik;Jang, Kab Yeul;Shin, Pyung Gyun
    • Journal of Mushroom
    • /
    • v.7 no.3
    • /
    • pp.130-134
    • /
    • 2009
  • To develop new white variety of Oyster mushroom, all white varieties which have been collected and kept in the lab were revived and screened their cultural characteristics. 84 intra-specific Oyster mushroom hybrids between the white-colored mutants Suhan and Wonhyeong were developed using hyphal anastomosis technique in 2007. The Po2007-63 ($2842-7{\times}0205-7$) was shown the best cultural characteristics, selected to be a new variety and named as 'Goni'. The new commercial strain, 'Goni' has white pilei and grows well under spring and autumn conditions in Korea. The fruiting bodies of 'Goni' are of an excellent quality in that not only the stipe is thick and long but also the pileus is small and hard. The optimum temperatures for mycelial growth and fruiting body development were $25-30^{\circ}C$ and $10-16^{\circ}C$, respectively. Time period required for the initiation of the first fruiting body is about 3 to 5 days depending on the temperatures. The shape of fruiting body is thin funnel shape. Fruiting body production per bottle was about $91{\pm}13$ g which is almost 97% quantity compared to that of other variety 'Miso'. Relatively low temperature incubation ($11^{\circ}C$) resulted in the development of better quality of 'Goni' mushrooms. When two different media including potato dextrose medium and mushroom complete medium were compared, the growth of mushroom were much faster in mushroom complete medium at $20-25^{\circ}C$, but not at $25^{\circ}C$. Similar results were observed with other variety 'Miso'. Analysis of the genetic characteristics of the new commercial strain 'Goni' showed a major DNA profile as that of the parental Suhan when primer URP 1 was used, but different to 'Miso' that was used as a control. When screens were performed with primer URP 2, DNA patterns were similar both to that of the parents and 'Miso'. This new variety of the white Oyster mushroom has a clean and fresh image that corresponds well to "health food". We therefore expect that this new strain will satisfy the consumers demand for variety and excellent mushrooms.

  • PDF

Biological stability of Zirconia/Alumina composite ceramic Implant abutment (지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구)

  • Bae, Kyu-Hyun;Han, Jung-Suk.;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.