The vision system is easy to use the exclusive use as a independent computer system but it is not much popularization by reason of expensive and difficult to adapt to the various fields, because it is easy to the existed computer system, the price is cheap and also it can use to the various measurement purpose which user wanted and programed. The measurement method of the vehicle axle casing nut welding part is that measure the value of the welding part to adapt the actual operation program from using the ratio between the actual length of the standard specimen and the length of image, to measure the ratio between the actual product and the camera image. A defect is found by the assembled visual inspection system. The inspection algorithm which estimates the quality of welded product is developed and also, the software program which processes the automatic test function of the inspection system. We make the foundation of the inspection automatic system and we will help to apply other welding machine.
블록 기반의 변환 부호화 방식은 영상 압축 표준에 널리 사용되고 있다. 이러한 방식에서 발생하는 여러 종류의 화질 열화 현상 중 블록의 경계에서 나타나는 블록화 현상은 화질을 떨어뜨리는 대표적인 요인이다. 블록화 현상에 의한 화질 열화는 기존의 PSNR 같은 화질 측정값과 부합하지 않아 새로운 평가 기법의 개발이 필요하다. 본 논문은 블록 기반 변환 부호화 방식으로 압축된 영상에서 블록화 현상이 발생한 정도를 측정하여 화질을 평가하는 새로운 기법을 제안한다. 본 논문에서 제안하는 기법은, 블록화 현상이 블록 경계에서 발생하면 경계면에서 양쪽 화소의 밝기값의 차이가 나며, 대개 그 길이가 블록의 경계 길이 만큼 이어지는 특징을 이용하여 블록화 현상을 찾아낸다. 본 논문에서 제안하는 방법은 원본 영상이 필요치 않고, 블록 경계에서 동작하며, 블록화 현상의 발생 정도를 수치화 한다. 다양한 압축 영상에 본 기법을 적용한 결과, 제안하는 블록화 현상 평가 수치는 인간의 시각 특성에 기반한 주관적 화질 평가와 부합하는 것을 확인하였다.
본 연구는 CR영상에서 선량이 화질에 미치는 영향을 평가하기위해 수행되었다. 본 연구의 궁극적인 목적은 임상 흉부진단에 필요한 영상화질을 얻을 수 있는 최적 선량을 찾는 것이다. 영상화질 평가를 위해서 다양한 선량에서의 MTF, NNPS, 그리고 NEQ를 측정하였으며, MTF 측정과 실험장치 구성은 International Electrotechnical Commission(IEC)에서 제시한 절차에 따라 수행하였다. 실험 결과를 통해 흉부진단의 경우 자동노출조절 (Automatic Exposure Control, AEC) 제어반에서 자동으로 설정해주는 선량의 절반 선량으로도 필요한 영상화질이 얻어짐을 알 수 있었다. 본 연구를 통해 AEC에서 제시하는 선량이 최적 선량이 아니며 화질평가를 통해서 얻어진 최적 선량을 사용하면 환자의 피폭을 상당량 줄일 수 있음을 보였다.
Purpose: The objective of this study was to evaluate and compare the accuracy and image quality of root surface area (RSA) measurements obtained with various cone-beam computed tomography (CBCT) protocols, relative to the gold standard of micro-computed tomography (CT), in an in vitro setting. Materials and Methods: Four dry human skulls were scanned using 8 different protocols, with voxel sizes of 0.15 mm, 0.3 mm, and 0.4 mm. Three-dimensional models of the selected teeth were constructed using CBCT and microCT protocols, and the RSA was automatically measured by the image-processing software. The absolute difference in the percentage of the RSA(%ΔRSA) was calculated and compared across the 8 CBCT protocols using repeatedmeasures analysis of variance. Finally, image quality scores of the RSA measurements were computed and reported in terms of percent distribution. Results: No significant differences were observed in the %ΔRSA across the 8 protocols (P>0.05). The deviation in %ΔRSA ranged from 1.51% to 4.30%, with an increase corresponding to voxel size. As the voxel size increased, the image quality deteriorated. This decline in quality was particularly noticeable at the apical level of the root, where the distribution of poorer scores was most concentrated. Conclusion: Relative to CBCT protocols with voxel sizes of 0.15mm and 0.3mm, the protocols with a voxel size of 0.4 mm demonstrated inferior image quality at the apical levels. In spite of this, no significant discrepancies were observed in RSA measurements across the different CBCT protocols.
Chlorophyll-a concentration maps of Yongdam reservoir in September and October, 2001 were produced using Landsat ETM imagery and the in-situ water quality measurement data. In-situ water samples were collected on 16th September and 18th October during the satellite overpass. The correlations between the DN values of the imagery and the values of chlorophyll-a concentration were analyzed. The visible bands(band 1, 2, 3) and the near infrared band(band 4) data of September image showed the correlation coefficient values higher than 0.9. The October image showed correlation coefficient values of about 0.7 due to the low variations of chlorophyll-a concentration. Regression models between the DN values of the Landsat ETM image and the chlorophyll-a concentration have been developed for each image. The developed regression models were then applied to each image, and finally the chlorophyll-a distribution maps of Yongdam reservoir were produced. The produced maps showed the spatial distribution of the chlorophyll-a in Yongdam reservoir in a synoptic way so that the tropic state could be easily monitored and analysed in the spatial domain.
본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.
Over the last few years computer based image processing has become more prominent in forensic science. The image quality from many CCTV systems is too poor for facial recognition. but there are other human characteristics which allow us to recognize individuals from a distance. one of these parameters is a human's height. In this paper, we propose useful height measurement method by auto Position, size adjustment which uses image superimposition and edge detection regardless of lens distortion and not uses conventional photogrammetry calibration methods.
The contrast ratio is one of the most important performance parameters for display devices. The general method of measuring the contrast ratio is to determine the ratio of the full-screen white pattern to the full-screen black pattern, according to the Video Electronics Standards Association standard. Real TV images seldom have these images, however, and the conventional method does not reflect the true performance of the display in actual use. In this paper, a new contrast ratio measurement method that uses image patterns is proposed, to demonstrate that active matrix organic light-emitting diode TVs have a higher contrast than LED (LCD) TVs.
Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.
골밀도의 질 관리는 검사를 시행하는 방사선사들의 책임과 의무이다. 하지만 질 관리의 이해 부족과 방법의 무지로 인한 잘못된 결과는 환자에게 치명적인 오류를 범할 수 있다. 따라서 이 논문은 올바른 질 관리의 이해와 방법을 기술하여 검사자 및 환자, 의뢰의사에게 골밀도 검사의 신뢰성을 확보하는 것을 목적으로 한다. 이중 에너지 엑스선 골밀도 기기(dual energy X-ray absorptiometry, DXA)는 골밀도 측정은 정확도와 정밀도가 우수하여야 작은 골량의 변화에도 진정한 생물학적 변화를 알 수 있다. 따라서 정확도와 정밀도를 높이기 위한 수단으로 장비 및 검사자의 올바른 질 관리가 지속적으로 이루어져야 한다. 올바른 장비관리방법은 매일 아침 장비 보정 질 관리 후 제조사에서 권고하는 팬텀을 이용하여 10~25회 측정하여 평균값을 구하고 이를 기준으로 허용 범위(${\pm}1.5%$)를 지정한다. 팬텀의 측정은 검사가 있는 날에 매일 측정하거나 일주일에 3회 이상 측정하여 실제 골밀도의 값의 변화 유무를 확인하여야 한다. 또한 측정된 팬텀의 골밀도수치를 기록 한 Shewart control chart를 Rule에 따라 평가한다. 이러한 관리는 장비의 설치 및 이동 시에 반드시 행해져야 한다. 검사자 관리방법은 정밀도 측정으로 평가하는데 정밀도는 재검사하였을 때에 실제 생물학적 변화 없이 수치상의 결과 값을 똑같이 재현될 수 있는지 알아보는 것이다. 측정 방법은 골밀도 검사를 진행하면서 환자를 두번씩 30번 측정하는 방법과 세번씩 15번 측정하는 방법이 있다. 측정에서 중요한 것은 한 번 검사 후 두번째나 세번째 검사에서도 반드시 검사 테이블에서 내려왔다 다시 올라가서 검사를 해야 한다. 측정된 골밀도수치로 정밀오차를 산출하고 95% 신뢰수준으로 정밀오차에 2.77을 곱하여 최소한의 생물학적 골밀도 변화를 산출한다. 산출된 값을 최소한의 의미있는 변화라고 표현하며 이 값을 넘어섰을 경우가 진정한 생물학적 변화구간이라고 할 수 있다. 검사자의 정도관리는 처음 검사를 시작하는 경우와 장비의 이동 및 교체 시에 반드시 행해져야하며 지속적으로 이루어져야 한다. 골밀도 검사를 시행하는 방사선사의 올바른 질 관리의 수행은 장비의 수명 연장과 정확한 결과의 산출로 이어져 검사의 신뢰성 확보와 환자 및 방사선사에게 부적절한 검사로 인한 방사능 노출의 최소화에 도움을 줄 것이다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.