• Title/Summary/Keyword: Image method

Search Result 17,782, Processing Time 0.046 seconds

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Analysis of $^{99m}Tc-ECD$ Brain SPECT images in Boys and Girls ADHD using Statistical Parametric Mapping(SPM) (통계적 파라미터지도 작성법(SPM)을 이용한 남여별 ADHD환자의 뇌 SPECT 영상비교분석)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.31-41
    • /
    • 2004
  • Attention deficit hyperactivity disorder(ADHD)is one of the most common psychiatric disorders in childhood, especially school age children and persisting into adult. ADHD is affected 7.6% in our children, Korea. and persisting into $15{\sim}20%$ in adult. And it is characterized by hyperactivity, inattention and impulsivity. Brain imaging is one of way to diagnosis for ADHD. Brain imaging studies may be provide information two types - structural and functional imaging. Structural and functional images of the brain play an important role in management of neurologic and psyciatric disorders. Brain SPECT, with perfusion imaging radiopharmaceuticals is one of the appropriate test to diagnosis of neurologic and psychiatric diseases. Ther are a few studies about separated analysis between boys and girls ADHD SPECT brain images. Selection of Probability level(P-value) is very important to determind the abnormalities when analysis a data by SPM. SPM is a statistical method used for image analysis and determine statistical different between two groups-normal and ADHD. Commonly used P-value is P<0.05 in statistical analysis. The purpose of this study is to evaluation of blood flow clusters distribution, between boys and girls ADHD. The number of normal boys are 8(6-7y, average : $9.6{\pm}3.9y$) and 51(4-11y, average : $9.0{\pm}2.4$) ADHD patients, and normal girls are 4(6-12y, average : $9{\pm}2.4y$) and 13(2-13y, average $10{\pm}3.5y$) ADHD patiens. Blood flow tracer $^{99m}Tc-ethylcysteinate$ dimer(ECD) injected as rCBF agent and take blood flow images after 30 min. during sleeping by SPECT camera. The anatomical region of hyperperfusion of rCBF in boys ADHD group is posterior cingulate gyrus and hyperperfusion rate is 15.39-15.77% according to p-value. And girls ADHD group appears at posterior cerebellum, Lt. cerbral limbic lobe and Lt. Rt. cerebral temporal lobe. These areas hyperperfusion rate are 24.68-31.25%. Hypoperfusion areas in boys ADHD,s brain are Lt. cerebral insular gyrus, Lt. Rt. frontal lobe and mid-prefrontal lobe, these areas decresed blood flow as 15.21-15.64%. Girls ADHD decreased blood flow regions are Lt. cerebral insular gyrus, Lt. cerebral frontal and temporal lobe, Lt. Rt. lentiform nucleus and Lt. parietal lobe. And hypoperfusion rate is 30.57-30.85% in girls ADHD. The girls ADHD group's perfusion rate is more variable than boys. The studies about rCBF in ADHD, should be separate with boys and girls.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Early and Midterm Results of the Extracardiac Fontan Operation and the Change of Internal Diameter of the Conduit (심외도관 폰탄수술후 중단기 성적 및 심외도관의 내경의 변화)

  • 성시찬;김시호
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.177-181
    • /
    • 2002
  • Background: Follow-up studies have shown that although outcomes have improved substantially over time, results of the Fontan operation and its modifications remain suboptimal. In this study, we reviewed our experience with the extracardiac conduit Fontan operation, with a focus early and midterm change of internal diameter of PTFE conduit. Material and Method: Between April 1997 and July 2000 were reviewed. Twelve patients (M:6, F:6, mean age 42.04 $\pm$ 12.43months, mean body weight 13.80$\pm$ 1.94kg) underwent extracardiac conduit Fontan operation with expanded PTFE graft. Mean cardiopulmonary bypass time was 109.7$\pm$26.99minute and mean operation time was 455$\pm$89.51minute. Intraoperative fenestration was performed in 10 patients. The aortic cross clamping was not performed in all patients. Result: There was no early deaths and no postoperative dysrhythmia. Postoperative protein losing enteropathy and prolonged pleural effusion occurred in 1(8.3%) and 4 patients(33.3%). Conduit patency was evaluated by magnetic resonance imaging studies. A 9.84$\pm$3.84% mean reduction in conduit internal diameter and there was no statistical correlation between the change of internal diameter of conduit and the postoperative duration after partial correlation analysis(r=0.019, p=0.955). Conclusion: These results demonstrate that the extracardiac conduit Fontan operation provies good early and midterm results and may reduce the prevalence of late arrhythmia. And there is no correlation between the change of internal diameter of conduit and the postoperative duration after extracardiac conduit Fontan operation with the expanded PTFE graft conduit.

Preference and Tourism Behaviors of the Tourists to the Travel-Destinations in the Eastern Area of Chonnam Province (전남 동부지역 관광지의 선호도와 관광행태에 관한 연구)

  • Chu, Myung-Hee;Lee, Joeng-Rock;Kim, Jae-Chul
    • Journal of the Korean association of regional geographers
    • /
    • v.2 no.1
    • /
    • pp.115-131
    • /
    • 1996
  • Tourism is multi-faceted phenomenon which involves movement to stay in destinations outside the normal place of residence. Thus, tourism is a composite phenomenon which incorporates the diversity of variables and relationships to be found in the tourist travel process. Tourism-behaviors are of major economic and social significance. With the growth of mass-tourism, the government departments of tourism is to provide many tourist facilities, to develop travel destination and tourism resources. At same time, the growth of mass-tourism has prompted perceptive travellers to raise many questions concerning the many travel destination and the tourism resources of encouraging further tourism demand. Most of tourism have a mental in their minds about various objects. This allowed him to choose tourism destination as a important rules. In tourism geography, behavioral approach to wildness, tourism resources and places has risen since 1960's. The tourist profile can be viewed under two major categories: the tourist social-economic and behavioral characteristic. Particulary, the motivations, attitude, need, values and preference of travel destinations are of crucial importance in contributing to their desion-making process. In this view, this paper is emprical study investigated travel patterns and behavioral characteristic of tourists and potential tourist in East Chonnam. The purpose of this paper is to show the spatial preference and tourism behavior of travel destinations. For this study, we are undertaken the questionary method employed by recreation geographers in order to collect research data for the East Chonnam-citizens functioned as a major tourist demand. The East Chonnam Province have many tourist-places including national park, provincial park, and local tourist-places. Thus, citizen of the East Chonnam evaluate many tourist-places very high, but evaluate the facilities of tourist place very low. The high ranks of preferences to travel destinations among tourist-places are Hyangilam, Geomoon island, Odongis land, Songkwang temple. The major travel destinations occurred the temporary travel trip are Odong island, Sunam temple, Songkwang temple. Heungkook temple, Hyangilam which are the type of mountainous in located inland. The relationship between the degree of preference and tourism behavior of travel trip for the travel destinations does not correlate each other. The result of analysis about the degree of seasonal preferences presented spatial differences according to characteristics of tourist-places. The typical travel destination are divided into seasons : Odong island. Mt. Backwoon, Goemoon island of spring, Goemoon island, Sungbul valley, Banggukpo beach of summer, Songkwang temple, Mt. Pal young of fall. The future of tourism will be rapidly grow with increase of personal mobility and leisure time, chang of tourism behavior. Thus, it is imperative that planning and development for tour-root, facilities of tourist-places should be implemented to increase tourism demand.

  • PDF

Estimation of Soil Loss Due to Cropland Increase in Hoeryeung, Northeast Korea (북한 회령지역의 농경지 변화에 따른 토양침식 추정)

  • Lee, Min-Boo;Kim, Nam-Shin;Kang, Chul-Sung;Shin, Keun-Ha;Choe, Han-Sung;Han, Uk
    • Journal of the Korean association of regional geographers
    • /
    • v.9 no.3
    • /
    • pp.373-384
    • /
    • 2003
  • This study analyses the soil loss due to cropland increase in the Hoeryeung area of northeast Korea, using Landsat images of 1987 TM and 2001 ETM, together with DTED, soil and geological maps, and rainfall data of 20 years. Items of land cover and land use were categorized as cropland, settlement, forest, river zone, and sand deposit by supervised classification with spectral bands 1, 2 and 3. RUSLE model is used for estimation of soil loss, and AML language for calculation of soil loss volumes. Fourier transformation method is used for unification of the geographical grids between Landsat images and DTED. GTD was selected from 1:50,000 topographic map. Main sources of soil losses over 100 ton/year may be the river zone and settlement in the both times of 1987 and 2001, but the image of the 2001 shows that sources areas have developed up to the higher mountain slopes. In the cropland average, increases of hight and gradient are 24m and $0.8^{\circ}$ from 1987 to 2001. In the case of new developed cropland, average increases are 75m and $2.5^{\circ}$, and highest soil loss has occurred at the elevation between 300 and 500m. The soil loss 57 ton of 1987 year increased 85 ton of 2001 year. Soil loss is highest in $30{\sim}50^{\circ}$ slope zones in both years, but in 2001 year, soil loss increased under $30^{\circ}$ zones. The size of area over 200 ton/year, indicating higher risk of landslides, have increased from $28.6km^2$ of 1987 year to $48.8km^2$ of 2001 year.

  • PDF

A New Bias Scheduling Method for Improving Both Classification Performance and Precision on the Classification and Regression Problems (분류 및 회귀문제에서의 분류 성능과 정확도를 동시에 향상시키기 위한 새로운 바이어스 스케줄링 방법)

  • Kim Eun-Mi;Park Seong-Mi;Kim Kwang-Hee;Lee Bae-Ho
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.11
    • /
    • pp.1021-1028
    • /
    • 2005
  • The general solution for classification and regression problems can be found by matching and modifying matrices with the information in real world and then these matrices are teaming in neural networks. This paper treats primary space as a real world, and dual space that Primary space matches matrices using kernel. In practical study, there are two kinds of problems, complete system which can get an answer using inverse matrix and ill-posed system or singular system which cannot get an answer directly from inverse of the given matrix. Further more the problems are often given by the latter condition; therefore, it is necessary to find regularization parameter to change ill-posed or singular problems into complete system. This paper compares each performance under both classification and regression problems among GCV, L-Curve, which are well known for getting regularization parameter, and kernel methods. Both GCV and L-Curve have excellent performance to get regularization parameters, and the performances are similar although they show little bit different results from the different condition of problems. However, these methods are two-step solution because both have to calculate the regularization parameters to solve given problems, and then those problems can be applied to other solving methods. Compared with UV and L-Curve, kernel methods are one-step solution which is simultaneously teaming a regularization parameter within the teaming process of pattern weights. This paper also suggests dynamic momentum which is leaning under the limited proportional condition between learning epoch and the performance of given problems to increase performance and precision for regularization. Finally, this paper shows the results that suggested solution can get better or equivalent results compared with GCV and L-Curve through the experiments using Iris data which are used to consider standard data in classification, Gaussian data which are typical data for singular system, and Shaw data which is an one-dimension image restoration problems.

The Role of Open Lung Biopsy in Diagnosis and Treatment of Diffuse Interstitial Lung Disease in High-resolution Computed Tomography Era (고해상도 전산화단층촬영 시대에 있어서 미만성 간질성 폐질환의 진단 및 치료에서의 개흉폐생검의 역할)

  • Kim, Gye Su;Lee, Jae Chul;Lee, Seung Joon;Yoo, Chul-Gyu;Kim, Young Whan;Han, Sung Koo;Min, Kyung Up;Im, Jung-Gi;Kim, You Young;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.746-754
    • /
    • 1996
  • Objective: Diffuse interstitial lung disease (DILD) is a group of diverse diseases that share conUTIon clinical, radiologic, and pulomonary function features. Open lung biopsy (OLB) has been regarded as gold standard in differential diagnosis of DILD. However open lung biopsy is a invasive diagnostic tool not free of its own risk or complications. These days, high-resolution computed tomography (HRCf) has become an important diagnostic tool in DILD through its precise image analysis. In many instances, HRCT could provide specific diagnosis or, at least, provide infonnation on the disease activity of DILD. The authors re-evaluate the role of open lung biopsy in this "HRCT era" by investigating the additional diagnostic gain and impacts on the treannent plan in patients who have undergone high-resolution CT. Method : Diagnoses obtained by high-resolution CT and open lung biopsy were compared and changes of treatment plans were evaluated retrospectively in 30 patients who had undergone open lung biopsy for the purpose of diagnosis of diffuse interstitial lung disease from March 1988 to June 1994. Results : High-resolution cr suggeted specific diagnoses in 22 out of 28 patients (78.6%) and the diagnoses were confinned (0 be correct by open lung biopy in 20 of those 22 cases (91%). Open lung biopsy could not give specific diagnosis in 5 out of 30 cases (16.7%). In 5 out of 6 cases (83.3%) in whom high reolution cr was not able to suggest specific diagnosis, open lung biopsy gave specific diagnoses. Treatment plan was altered by the result of open lWlg biopsy in only 2 cases. Conclusion: The aoove fmdings suggest that in "HRCT era", when HRCT could suggest specific diagnosis, the need for open lung biopsy should be re-evaluated.

  • PDF