• Title/Summary/Keyword: Image detector data

Search Result 207, Processing Time 0.028 seconds

An Automatic Strabismus Screening Method with Corneal Light Reflex based on Image Processing

  • Huang, Xi-Lang;Kim, Chang Zoo;Choi, Seon Han
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.5
    • /
    • pp.642-650
    • /
    • 2021
  • Strabismus is one of the most common disease that might be associated with vision impairment. Especially in infants and children, it is critical to detect strabismus at an early age because uncorrected strabismus may go on to develop amblyopia. To this end, ophthalmologists usually perform the Hirschberg test, which observes corneal light reflex (CLR) to determine the presence and type of strabismus. However, this test is usually done manually in a hospital, which might be difficult for patients who live in a remote area with poor medical access. To address this issue, we propose an automatic strabismus screening method that calculates the CLR ratio to determine the presence of strabismus based on image processing. In particular, the method first employs a pre-trained face detection model and a 68 facial landmarks detector to extract the eye region image. The data points located in the limbus are then collected, and the least square method is applied to obtain the center coordinates of the iris. Finally, the coordinate of the reflective light point center within the iris is extracted and used to calculate the CLR ratio with the coordinate of iris edges. Experimental results with several images demonstrate that the proposed method can be a promising solution to provide strabismus screening for patients who cannot visit hospitals.

A STUDY ON THE GENERATION OF EO STANDARD IMAGE PRODUCTS: SPOT

  • JUNG HYUNG-SUP;KANG MYUNG-HO;LEE YONG-WOONG;LEE HO-NAM;WON JOONG-SUN
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.216-219
    • /
    • 2004
  • In this study, the concept and techniques to generate the level lA, lB and 2A image products have been reviewed. In particular, radiometric and geometric corrections and bands registration used to generate level lA, lB and 2A products have been focused in this study. Radiometric correction is performed to take into account radiometric gain and offset calculated by compensating the detector response non-uniformity. And, in order to compensate satellite altitude, attitude, skew effects, earth rotation and earth curvature, some geometric parameters for geometric corrections are computed and applied. Bands registration process using the matching function between a geometry, which is called 'reference geometry', and another one which is corresponds to the image to be registered is applied to images in case of multi-spectral imaging mode. In order to generate level-lA image products, a simple radiometric processing is applied to a level-0 image. Level-lB image has the same radiometry correction as a level-lA image, but is also issued from some geometric corrections in order to compensate skew effects, Earth rotation effects and spectral misregistration. Level-2A image is generated using some geo-referencing parameters computed by ephemeris data, orbit attitudes and sensor angles. Level lA image is tested by visual analysis. The difference between distances calculated level 1 B image and distances of real coordinate is tested. Level 2A image is tested Using checking points.

  • PDF

Fast Image Pre-processing Algorithms Using SSE Instructions (SSE 명령어를 이용한 영상의 고속 전처리 알고리즘)

  • Park, Eun-Soo;Cui, Xuenan;Kim, Jun-Chul;Im, Yu-Cheong;Kim, Hak-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.65-77
    • /
    • 2009
  • This paper proposes fast image processing algorithms using SSE (Streaming SIMD Extensions) instructions. The CPU's supporting SSE instructions have 128bit XMM registers; data included in these registers are processed at the same time with the SIMD (Single Instruction Multiple Data) mode. This paper develops new SIMD image processing algorithms for Mean filter, Sobel horizontal edge detector, and Morphological erosion operation which are most widely used in automated optical inspection systems and compares their processing times. In order to objectively evaluate the processing time, the developed algorithms are compared with OpenCV 1.0 operated in SISD (Single Instruction Single Data) mode, Intel's IPP 5.2 and MIL 8.0 which are fast image processing libraries supporting SIMD mode. The experimental result shows that the proposed algorithms on average are 8 times faster than the SISD mode image processing library and 1.4 times faster than the SIMD fast image processing libraries. The proposed algorithms demonstrate their applicability to practical image processing systems at high speed without commercial image processing libraries or additional hardwares.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

A New Frame Synchronization Scheme for Underwater Ultrasonic Image Burst Transmission System (초음파를 이용한 수중 영상 버스트 전송 시스템을 위한 새로운 프레임 동기 방안)

  • Kim, Seung-Geun;Choi, Young-Chol;Park, Jong-Won;Kim, Sea-Moon;Lim, Yong-Gon;Kim, Sang-Tae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.336-340
    • /
    • 2003
  • The frame synchronization should be acquired before performing other data-aided receiving algorithms, such as data-aided channel equalizing, beam-forming and phase, symbol timing, and frequency synchronizing, since all of them are using preamble or training sequence to estimate the amount of error from the received signal. In this paper, we present a new frame synchronization scheme for underwater ultrasonic image burst transmission system, which computes the correlation between received symbol sequence and one CAZAC sequence, composed of the latter half of the first CAZAC sequence of preamble and the first half of the second CAZAC sequence of preamble and then compares a threshold value. If the correlation value is bigger than the threshold value, the frame detector determines that the frame synchronization is achieved at that sample.

  • PDF

Merging Features and Optical-NIR Color Gradient of Early-type Galaxies

  • Kim, Du-Ho;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • It has been suggested that merging plays an important role in the formation and the evolution of early-type galaxies. Optical-NIR color gradients of early-type galaxies in high density environments are found to be less steep than those in low density environment, hinting frequent merger activities in early-type galaxies in high density environment. In order to confirm if the flat color gradient is the result of dry merger, we decided to look deeply to find merging features and get their relation with color gradient. We selected samples which show extreme values of optical-NIR color gradients based on the data of previous study, and observed them at Maidanak observatory 1.5m telescope with long exposure. After masking out overlaid sources, our analysis reveals that these galaxies do not have extreme color gradient values. High degree sky flat technique was used during observation to aid discovery of faint, extended features. However, flatness of detector (SNUCAM) was good enough, so we could not see any marked improvement in image quality compared to those using normal sky flats. Additionally we noticed a feature that looks like merging tidal tail in the CFHT archival image, but this does not show up on the image we obtained. This demonstrates that flatness and correct sky estimation is very important when we look for faint merging features. In future we plan to enlarge the number of the sample.

  • PDF

Simple Fuzzy Rule Based Edge Detection

  • Verma, O.P.;Jain, Veni;Gumber, Rajni
    • Journal of Information Processing Systems
    • /
    • v.9 no.4
    • /
    • pp.575-591
    • /
    • 2013
  • Most of the edge detection methods available in literature are gradient based, which further apply thresholding, to find the final edge map in an image. In this paper, we propose a novel method that is based on fuzzy logic for edge detection in gray images without using the gradient and thresholding. Fuzzy logic is a mathematical logic that attempts to solve problems by assigning values to an imprecise spectrum of data in order to arrive at the most accurate conclusion possible. Here, the fuzzy logic is used to conclude whether a pixel is an edge pixel or not. The proposed technique begins by fuzzifying the gray values of a pixel into two fuzzy variables, namely the black and the white. Fuzzy rules are defined to find the edge pixels in the fuzzified image. The resultant edge map may contain some extraneous edges, which are further removed from the edge map by separately examining the intermediate intensity range pixels. Finally, the edge map is improved by finding some left out edge pixels by defining a new membership function for the pixels that have their entire 8-neighbourhood pixels classified as white. We have compared our proposed method with some of the existing standard edge detector operators that are available in the literature on image processing. The quantitative analysis of the proposed method is given in terms of entropy value.

A Study on Measurement of Repetitive Work using Digital Image Processing (영상처리를 이용한 반복적 작업의 측정에 관한 연구)

  • Lee, Jeong-Cheol;Sim, Eok-Su;Kim, Nam-Joo;Park, Chan-Kwon;Park, Jin-Woo
    • IE interfaces
    • /
    • v.14 no.1
    • /
    • pp.95-105
    • /
    • 2001
  • Previous work measurement methods need much time and effort of time study analysts because they have to measure required time through direct observations. In this study, we propose a method which efficiently measures standard times without involvement of human analysts using digital image processing techniques. This method consists of two main steps: motion representation step and cycle segmentation step. In motion representation step, we first detect the motion of any object distinct from its background by differencing two consecutive images separated by a constant time interval. The images thus obtained then pass through an edge detector filter. Finally, the mean values of coordinates of significant pixels of the edge image are obtained. Through these processes, the motions of the observed worker are represented by two time series data of worker location in horizontal and vertical axes. In the second step, called the cycle segmentation step, we extract the frames which have maximum or minimum coordinates in one cycle and store them in a stack, and calculate each cycle time using these frames. In this step we also consider methods on how to detect work delays due to unexpected events such as operator's escapement from the work area, or interruptions. To condude, the experimental results show that the proposed method is very cost-effective and useful for measuring time standards for various work environment.

  • PDF

Segmentation of the Glottis and Quantitative Measurement of the Vocal Cord Mucosal Morphology in the Laryngoscopic Image (후두 내시경 영상에서의 성문 분할 및 성대 점막 형태의 정량적 평가)

  • Lee, Seon Min;Oh, Seok;Kim, Young Jae;Woo, Joo Hyun;Kim, Kwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.5
    • /
    • pp.661-669
    • /
    • 2022
  • The purpose of this study is to compare and analyze Deep Learning (DL) and Digital Image Processing (DIP) techniques using the results of the glottis segmentation of the two methods followed by the quantification of the asymmetric degree of the vocal cord mucosa. The data consists of 40 normal and abnormal images. The DL model is based on Deeplab V3 architecture, and the Canny edge detector algorithm and morphological operations are used for the DIP technique. According to the segmentation results, the average accuracy of the DL model and the DIP was 97.5% and 94.7% respectively. The quantification results showed high correlation coefficients for both the DL experiment (r=0.8512, p<0.0001) and the DIP experiment (r=0.7784, p<0.0001). In the conclusion, the DL model showed relatively higher segmentation accuracy than the DIP. In this paper, we propose the clinical applicability of this technique applying the segmentation and asymmetric quantification algorithm to the glottal area in the laryngoscopic images.

92 GHz Radiometer System for Remote Sensing Applications

  • Kim, Yong-Hoon;Kim, Sung-Hyun;Kang, Gum-Sil;Kim, Han-Sik;Yang, Ki-Seok
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.462-467
    • /
    • 1999
  • In this paper, very high performance millimeter-wave radiometer of 92 GHz is presented. Radiometer system design, brightness temperature measurement and calibration methods are described. The architecture of radiometer including data acquisition, storage and digital signal processing using a notebook computer are explained and some experimental data in the laboratory are introduced. The system noise figure and total gain of implemented radiometer are 12 dB and 56 dB, respectively. The system stability is evaluated from the experiment. The difference of the detector output voltage for two targets, whose brightness temperature are 80 K and 300K, is 4 mV. The mechanical scanning method is considered to get a brightness temperature Image of the earth surface scene.

  • PDF