• Title/Summary/Keyword: Image Use

Search Result 6,147, Processing Time 0.043 seconds

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient (비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가)

  • Choi, Jae Won;Kim, Cheol Chong;Park, Su Yeon;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Purpose: Quantitative comparative evaluation of the difference in eye lens absorbed dose when measured by MVCT and kV-CBCT, though such a dose was not included in the original IMRT treatment plan for the nasopharyngeal cancer patient. Materials and Methods: We used CT (Lightspeed Ultra 16, General Electric, USA) against an Anderson rando phantom (Alderson Research Laboratories Inc, USA) and established the plan for tomotherapy treatment (Tomotherapy, Inc, USA) and linear accelerator treatment (Pinnacle 8.0, Philips Medicle System) for the achieved CT images on the same condition with the nasopharyngeal cancer patient treatment plan. Then, align the ther-moluminescence dosimeter (TLD100 Harshaw, USA) with the eye lens, shot the lens with Tomotherapy MVCT under 3 conditions (Fine, Normal, and Coarse), and shot both lenses with kV-CBCT under 2 conditions (Low Dose Head and Standard Dose Head) 3 times each. Results: When we analyzed the eye lens absorbed dose according to MVCT and kV-CBCT images by using both Tomotherapy and Pinacle 8.0, we achieved the following result; According to Tomotherapy MVCT, RT 0.8257 cGy in the Coarse mode, LT 0.8137 cGy, RT 1.089 cGy and LT 1.188 cGy in the Normal mode, and RT 2.154 cGy and LT 2.082 cGy in the Fine mode. According to Pinacle 8.0 kV-CBCT, RT 0.2875 cGy and LT 0.1676 cGy in the Standard Dose mode and RT 0.1648 cGy and LT 0.1212 cGy in the Low-Dose mode. In short, the MVCT result was significantly different from that of kV-CBCT, up to 20 times. Conclusion: We think kV-CBCT is more effective for reducing the amount of radiation which a patient is receiving during intensity modulated radiation treatment for other purposes than treatment than MVCT, when we consider the absorbed dose only from the viewpoint of image-guided radiation therapy. Besides, we understood the amount of radiation is too sensitive to the shooting condition, even when we use the same equipment.

  • PDF

A Study on the Dépaysement of the Animation (애니메이션에 있어서 데페이즈망에 관한 연구)

Control Policy for the Land Remote Sensing Industry (미국(美國)의 지상원격탐사(地上遠隔探査) 통제제탁(統制制度))

  • Suh, Young-Duk
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.20 no.1
    • /
    • pp.87-107
    • /
    • 2005
  • Land Remote Sensing' is defined as the science (and to some extent, art) of acquiring information about the Earth's surface without actually being in contact with it. Narrowly speaking, this is done by sensing and recording reflected or emitted energy and processing, analyzing, and applying that information. Remote sensing technology was initially developed with certain purposes in mind ie. military and environmental observation. However, after 1970s, as these high-technologies were taught to private industries, remote sensing began to be more commercialized. Recently, we are witnessing a 0.61-meter high-resolution satellite image on a free market. While privatization of land remote sensing has enabled one to use this information for disaster prevention, map creation, resource exploration and more, it can also create serious threat to a sensed nation's national security, if such high resolution images fall into a hostile group ie. terrorists. The United States, a leading nation for land remote sensing technology, has been preparing and developing legislative control measures against the remote sensing industry, and has successfully created various policies to do so. Through the National Oceanic and Atmospheric Administration's authority under the Land Remote Sensing Policy Act, the US can restrict sensing and recording of resolution of 0.5 meter or better, and prohibit distributing/circulating any images for the first 24 hours. In 1994, Presidential Decision Directive 23 ordered a 'Shutter Control' policy that details heightened level of restriction from sensing to commercializing such sensitive data. The Directive 23 was even more strengthened in 2003 when the Congress passed US Commercial Remote Sensing Policy. These policies allow Secretary of Defense and Secretary of State to set up guidelines in authorizing land remote sensing, and to limit sensing and distributing satellite images in the name of the national security - US government can use the civilian remote sensing systems when needed for the national security purpose. The fact that the world's leading aerospace technology country acknowledged the magnitude of land remote sensing in the context of national security, and it has made and is making much effort to create necessary legislative measures to control the powerful technology gives much suggestions to our divided Korean peninsula. We, too, must continue working on the Korea National Space Development Act and laws to develop the necessary policies to ensure not only the development of space industry, but also to ensure the national security.

  • PDF

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

The concept of Sang(象) and its application in the Oriental Medicine (상(象)의 개념(槪念)과 한의학적(韓醫學的) 적용(適用))

  • Baek, Yu-Sang;Park, Chan-Guk
    • Journal of Korean Medical classics
    • /
    • v.12 no.2
    • /
    • pp.92-109
    • /
    • 1999
  • They say Y$\breve{o}$k'ak(易學) is the root of Oriental studies. This means philosophy, astronamy, geography, medicine, music, numbers are all based on Yin-Yang, and Five phases theory of Y$\breve{o}$k'ak. Nowadays studies are very much specialized but as we go back to old times, we cannot dearly set these studies apart. All the studies can be comprehensively understood with Y$\breve{o}$k'ak(易學). The original purpose of Y$\breve{o}$k'ak is to predict future with highly symbolized signs, Sang-Su(象數). However you cannot fully understand Y$\breve{o}$k'ak without knowing the principle of change in Sang-Su itself. We have to keep thinking about how we should further study Y$\breve{o}$k'ak, treat diseases with Sang-Su, and how Sang-Su can be used in medicine. As a previous step to this process, I will consider relationship of Y$\breve{o}$k'ak and medicine in this paper. This study will help us to set the goal and method in studying medicine. Conclusions of this paper are following: 1. The purpose of understanding a subject is to understand the principle of the subject. The principle of every subject can be turned into principle of changes in the universe. This principle is not affected by time nor space. It is only seen through the changes of subjects. 2. The reason we cannot easily understand the principle is that we have biased mind. How we should overcome this is through developing virtue, and by keep inspecting things over and over. 3. We see the outcome of changes inside but we should not neglect the principle. Therefore we see the principle through Sang. Sang is in between Principle(理) and Things(物), thereby has characteristics of both. Which means it is much like Principle but specific Things is related and it is much like Things but it is not easily understood. 4. There are various kinds of Sang. Mind-Sang(心象) is an image that comes before expressing it with symbols or words. When it is expressed in symbols or words, it is no longer considered as same Sang. Sang in symbol are Kwaesang(卦象), Hyosang(爻象) and Sang in words is Kyesa(卦辭). The characteristic of all these Sang is that it cannot be explained through the logics. 5. If we call Sanghak as the study with Sang, the method is same as that of understanding the principle. The fundamental purpose of Sanghak is to understand the principle of things and then apply this principle to the practical world so that the world can be a better place. So I would say Sanghak is the study of a saint and a ruler. 6. Since the object of medicine is human being who are the mixture of Principle and Ki, we can use Sang which is also related to both Principle and Ki. Actually terms we use in Oriental medicine are not easily understood without the knowledge of Sanghak. 7. When we diagnose a patient, we are looking for Sang that comes from the body inside. When we do the treatment, we cannot neglect the original change that's happening in our body. Therefore studying Sang is a necessary step to do the full diagnosis and treatment. 8. The method of studying medicine is first to get rid of biased mind, taking right Sang from various classics and then apply those Sang to actual situations.

  • PDF

A Study on Methods for the Visualization of Stage Space through Stage Lighting (무대조명을 통한 무용 예술의 무대공간 시각화 방안 연구)

  • Lee, Jang-Weon;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.16-28
    • /
    • 2009
  • Stage art basically builds upon the essence of "seeing," and at the same time, possesses relativity in showing and seeing. Stage lighting uses artificial light to solve the essence of "seeing", which is the foundation of stage art, and coming into the modern age, its role has been enhanced to an important medium for visual expression in stage art, due to the lighting tools that developed at a rapid pace along with the discovery of electricity, as well as the development of optics. Therefore, not only does lighting use a medium known as light in a field of stage art that gives mental and emotional inspiration to the audience, and aesthetically expresses time and space. In other words, stage lighting is a complex function of light engineering (technology and science) and aesthetic sense (feeling and art). This study aims to do research on methods for the visualization of stage space through lighting, mainly focused on dancing. I have studied the basics of stage lighting, its relations with other fields of stage art, and the functions and characteristics of lighting. Results show that lighting could be used to maximize the visualization of dancing and emphasizing the artistic growth of lighting and its ability to aesthetically express and I came to the following conclusions. First, lighting uses the forms and directions of light that various tools are able to produce in order to visualize the space on stage, and can maximally express the image that the work seeks. Second, it is possible to use lighting, through the movement of light, as a visual representation of the configuration of space in dancing works. Third, through the expression of visual and spatial aspects created by light, the work's dramatic catharsis can bring out mental and emotional feelings form the audience. Fourth, lighting can be seen not as a supporting role, but as an original visual design. To conclude, in order for lighting to be freed form the simple function of "lighting up the stage," which a majority of people think is common knowledge, and grow as one area in art, lighting designers must understand the intentions of the choreographer and the work with creativity and artistry they must consider light and color as an aesthetic language in order to heighten the effects of the work and allow it to partake as one element of work creation, so that lighting will be treated as a form of art.

"A Study on Hebrews Clothing in the Old Testament" - Especially on Hair Styles, Headgears, Footwear and Personal Ornaments - (구약성서(舊約聖書)에 나타난 히브리인의 복식(服飾) - 두식(頭飾), 신발 및 장신구(裝身具) 중심(中心)으로 -)

  • Park, Chan-Boo
    • Journal of the Korean Society of Costume
    • /
    • v.10
    • /
    • pp.63-80
    • /
    • 1986
  • The Old Testament cotains mention of the history of creation and clothing in ancient Hebrew. This study dealt with Hebrew dress customs especially aimed at the manners of their hair styles, headgears, footwear and personal ornaments. References are Korean Revised Version, English King James Version and Revised Standard Version. There is little mention of hair styles and headgears in the Old Testament. Some sort of turban was worn by priests, and soldiers protected themselves with helmets, but most Israelitish men went bareheaded except on special occasions and often wear simple headbands. It was more common for women to use headwear of some type-turbans, scarves, and veils concealing the face. The veil was the distinctive female wearing apparel. All females, with the exception of maidservants and women in a low condition of life, wore a veil. It was the custom for women to wear a veil entirely covering their head in the public. Through most of the Old Testament periods long and thick hair was admired on men and women alike. The Hebrews were proud to have thick and abundant long hair, and they gave much attention to the care of their hair. The caring of hair was deeply related to their rituals. Nazirites never took a razor to their hair during his vow-days, but instead let it grow long, as an offering to God. Men would not cut their beards, but allow them to grow long. The Israelites' standard footwear was a pair of simple leather sandals. This was one of the items of clothing not highly prized. In a colloquial saying of the time, a pair of shoes signified something of small value, and to be barefoot except in times of mourning or on holy place, was a sign either of extreme poverty or humiliation, as in the case of war prisoners. Because precious stones were not mined in the Palestine-Syria region, Hebrews imported them from foreign country. They were consumer-to a large degree limited by their very modest standard of living-but not producers. Hebrews liked the precious stones and were motivated to acquire and wear jewels. Besides their use for adornment and as gifts, the precious or semiprecious stones were regarded by Jews of property. The Hebrews were not innovators in the field of decorative arts. The prohibition of the Law against making any "graven image" precluded the development of painting, sculpture, and other forms of representational art. Jewish men did not indulge in extravagances of dress, and there was little ornamentation among them. Men wore a signet ring on their right hand or sometimes suspended by a cord or chain around the neck. The necklaces, when worn by a male, also bore any symbol of his authority. Bracelets were extremely popular with both men and women, men usually preferring to wear them on their upper arms. The girdle was a very useful part of a man's clothing. It was used as a waist belt, or used to fasten a man's sword to his body, or served as a pouch in which to keep money and other things. Men often carried a cane or staff, which would be ornamented at the top. Among the women there was more apt to be ornamentation than among the men. Hebrew women liked to deck themselves with jewels, and ornamentation of the bride were specially luxurious and numerous. They wore rings on their fingers or On toes, ankle rings, earrings, nosering, necklace, bracelets. Their shapes were of cresent, waterdrops, scarab, insect, animal or plant. Sometimes those were used as amulets. They were made of ceramics, gold, silver, bronze, iron, and various precious stones which were mostly imported from Egypt and Sinai peninsular. Hebrews were given many religious regulations by Moses Law on their hair, headgears, sandals and ornamentation. Their clothing were deeply related with their customs especially with their religions and rituals. Hebrew religion was of monotheism and of revealed religion. Their religious leaders, the prophets who was inspired by God might need such many religious regulations to lead the idol oriented people to God through them.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy (호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가)

  • Cho, Yoon-Jin;Jeon, Mi-Jin;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Sook;Im, Jung-Ho;Lee, Ik-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: It is essential to minimize the respiratory-induced motion of involved organs in the Tomotherapy for tumor located in the chest and abdominal region. However, the application of breathing control system to Tomotherapy is limited. This study was aimed to investigate the possible application of the ABCHES system and its efficacy as a means of breathing control in the tomotherapy treatment. Materials and Methods: Five subjects who were treated with a Hi-Art Tomotherapy system for lung, liver, gallbladder and pancreatic tumors. All patients undertook trained on two breathing methodes using an ABCHES, free breathing methode and shallow breathing methode. When the patients could carry out the breathing control, 4D-CT scan was a total of 10 4D tomographic images were acquired. A radiologist resident manually drew the tumor region, including surrounding nomal organs, on each of CT images at the inhalation phase, the exhalation phase and the 40% phase (mid-inhalation) and average CT image. Those CT images were then exported to the Tomotherapy planning station. Data exported from the Tomotherapy planning station was analyzed to quantify characteristics of dose-volume histograms and motion of tumors. Organ motions under free breathing and shallow breathing were examined six directions, respectively. Radiation exposure to the surrounding organs were also measured and compared. Results: Organ motion is in the six directions with more than a 5 mm displacement. A total of 12 Organ motions occurred during free breathing while organ motions decreased to 2 times during shallow breathing under the use of Abches. Based on the quantitative analysis of the dose-volume histograms shallow breathing showed lower resulting values, compared to free breathing, in every measure. That is, treatment volume, the dose of radiation to the tumor and two surrounding normal organs (mean doses), the volume of healthy tissue exposed to radiation were lower at the shallow breathing state. Conclusion: This study proposes that the use of ABCHES is effective for the Tomotherapy treatment as it makes shortness of breathing easy for patients. Respiratory-induced tumor motion is minimized, and radiation exposure to surrounding normal tissues is also reduced as a result.

  • PDF