• Title/Summary/Keyword: Image Separation

Search Result 388, Processing Time 0.024 seconds

Effect of Mold Temperature on the Separation and the Orientation during Compression Molding of Fiber-Reinforced Polymeric Composites (섬유강화 고분자 복합재료의 압축성형에 있어서 분리 ${\cdot}$ 배향에 미치는 금형온도의 영향)

  • Lee, Dong-Gi;Han, Gil-Young;Kim, E-Gon
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.123-132
    • /
    • 1995
  • During compression molding of fiber-reinforced polymeric composites, microstructural changes such as the fiber-matrix separation and the fiber orientation are occurred by the flow of composite materials. Since the nonhomogeneity and anisotropy of composites are caused by the separation and orientation of fibers. On the other hand, the separation and the orientation of fibers are inseparably related to each other. In this paper the degree of nonhomogeneity which is a measure of the separation is obtained using one-dimensional rectangular shaped part compression molding. And the orientation function is measured by the image processing using soft X-rayed photograph and image scanner. We study effects of the mold temperature on the degree of nonhomogeneity and the orientation function.

  • PDF

Time-Resolved Two-Phase PIV Measurements of Freely Rising Bubble Flows with an Image Separation Method (단일 카메라의 영상분리를 이용한 자유 상승 기포의 고속 이상 유동 PIV 계측)

  • Sung Jaeyong;Park Sang Min;Yoo Jung Yul
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • A time-resolved two-phase PIV system using a single camera has been developed, which introduces a method of image separation into respective phase images, and is applied to freely rising single bubble. Gas bubble, tracer particle and background have different gray intensity ranges on the same image frame when reflection and dispersion in the phase interface are intrinsically eliminated by optical filters and fluorescent particles. Further, the signals of the two phases do not interfere with each other. Gas phase velocities are obtained from the separated bubble image by applying the two-frame PTV. On the other hand, liquid phase velocities are obtained from the tracer particle image by applying the cross-correlation algorithm. As a result, the bubble rises rectilinearly just after it is released from an injector and then has a zigzag motion in the far field. From the trajectory of the bubble, it is found that the period of the zigzag motion is closely related to the vortex shedding although the wavelength of it varies along its movement.

  • PDF

A Study on Correlation Between Separation and Orientation of Fibres During Compression Molding of Long Fibre-Reinforced Polymeric Composites (장섬유강화 고분자복합판의 압축성형에 있어서 섬유의 분리와 배향의 상관관계에 관한 연구)

  • 이동기;유정훈;김이곤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.62-68
    • /
    • 1993
  • During compression molding of fibre-reinforced thermoplastics, the two main problems such as the fibre-matrix separation and the fibre orientation are produced by the flow state. As the molded product tends to be nonhomogeneous and anisotropic due to the separation and the orientation, it is necessary to clarify these in relation to the molding process variables and the fibre structure (fibre entanglement). If the entanglement of fibre structure is strong, the separation increases and the orientation is not easily aligned. Namely, these are inseparably related to each other. The correlation between the separation and the orientation have to be clarified for designing the fibre structure. In this paper, the degree of nonhomogeneity which is a measure of the separation is obtained using one-dimensional rectangular shaped part compression molding. And the orientation function is defined and measured by the image processing using soft X-rayed photograph and image scanner. Correlation between the degree of nonhomogeneity and the orientation function is discussed.

Image Separation Average Value Matching Method Development for Accuracy Improvement of Appearance Inspection (외관 검사의 정확도 향상을 위한 영상 분할 평균값 매칭 기법 개발)

  • Park, Se-Hyuk;Kang, Su-Min;Huh, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.445-446
    • /
    • 2007
  • The goal of this paper is accuracy improvement of appearance inspection by using image separation average value matching method. The appearance inspection of various electronic products and parts has been executed by the eyesight of human. But inspection by eyesight can't bring about uniform inspection result. Because the appearance inspection result by eyesight of human is changed by condition of physical and spirit of the checker. So machine vision inspection system is currently used to many appearance inspection fields instead of the checker. However the inspection result of machine vision is changed by the illumination of workplace. Therefore we have used a average value matching in this paper for improvement of vision inspection accuracy and could increase inspection accuracy of vision system. In other words, we made an effort for elevation of vision inspection accuracy by making the identical image separation average value of reference image and input image. Also this system has been developed only using PC, CCD Camera and Visual C++ for universal workplace.

  • PDF

Area Separation Histogram Specification Method for Accuracy Improvement of Vision Inspection (Vision 검사의 정확도 향상을 위한 영역 분할 히스토그램 지정 기법)

  • Park, Se-Hyuk;Huh, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.431-433
    • /
    • 2006
  • The goal of this paper is improvement of vision inspection accuracy by using histogram specification operation. The histogram is composed of horizontal axis of image intensity value and vertical axis of pixel number in image. In appearance vision inspection, the histogram of reference image and input image are different because of minutely lighting distinction. The minutely lighting distinction is main reason of vision inspection error in many cases. Therefore we made an effort for elevation of vision inspection accuracy by making the identical histogram of reference image and input image. As a result of this area separation histogram specification algorithm, we could increase the exactness of vision inspection and prevent system error from physical and spirit condition of human. Also this system has been developed only using PC, CCD Camera and Visual C++ for universal workplace.

  • PDF

A New Mobile Watermarking Scheme Based on Display-capture

  • Bae, Jong-Wook;Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.6
    • /
    • pp.815-823
    • /
    • 2009
  • Most of existing watermarking schemes insert and extract a watermark, focusing on the visual conservation of an original image. However, existing watermarking schemes could be difficult for a watermark detection in case of various distortion caused by display-capture devices. Therefore, we propose a new display-capture based mobile watermarking scheme. The proposed watermarking scheme is a new concept for embedding a watermark, which uses the generated image instead of a given original image. For effective watermark decoding, we also present a method for detecting the background image whose error bit can not be corrected because of various heavy distortion and for avoiding it from the decoding process. For this scheme, we adopt distortion coefficients of camera calibration when we separate a background image from a captured image. For finding available correction bits of ECC through the decoding process, we capture 30,000 images and then calculate the separation ratio of a background image and the average error bits per an image. As experimental result, the separation ratio of a background image is about 96.5% in 30,000 captured image. And the false alarm ratio shows about $5.18{\times}10^{-4}$ in the separated background image. And also we can confirm the availability of real-time processing because the mean execution time is about 82ms per an image for capturing and decoding.

  • PDF

A Research on the Vector Search Algorithm for the PIV Flow Analysis of image data with large dynamic range (입자의 이동거리가 큰 영상데이터의 PIV 유동 해석을 위한 속도벡터 추적 알고리즘의 연구)

  • Kim Sung Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.13-18
    • /
    • 1998
  • The practical use of the particle image velocimetry(PIV), a whole-field velocity measurement method, requires the use of fast, reliable, computer-based methods for tracking velocity vectors. The full search block matching, the most widely studied and applied technique both in area of PIV and Image Coding and Compression, is computationally costly. Many less expensive alternatives have been proposed mostly in the area of Image Coding and Compression. Among others, TSS, NTSS, HPM are introduced for the past PIV analysis, and found to be successful. But, these algorithms are based on small dynamic range, 7 pixels/frame in maximum displacement. To analyze the images with large displacement, Even and Odd field image separation and a simple version of multi-resolution hierarchical procedures are introduced in this paper. Comparison with other algorithms are summarized. A Results of application to the turbulent backward step flow shows the improvement of new algorithm.

  • PDF

Measurement of Sizes and Velocities of Spray Droplets by Image Processing Method (영상 처리에 의한 분무 액적의 크기 및 속도 추출)

  • Choo, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • In this study, the sizes and velocities of droplets in sprays were measured by image processing method from digital images of local region of sprays. The morphological method based on the Euclidean distance transform, Watershed separation, and perimeter image was adopted for the recognition and separation of overlapped particles. The match probability method was used for the particle tracking and pairing. The measurement results show that the present method may be reliable for the analysis of the motion and distribution of droplets produced by spray and atomization devices.

  • PDF

An Image Separation Scheme using Independent Component Analysis and Expectation-Maximization (독립성분 분석과 E-M을 이용한 혼합영상의 분리 기법)

  • 오범진;김성수;유정웅
    • Journal of KIISE:Information Networking
    • /
    • v.30 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • In this paper, a new method for the mixed image separation is presented using the independent component analysis, the innovation process, and the expectation-maximization. In general, the independent component analysis (ICA) is one of the widely used statistical signal processing schemes, which represents the information from observations as a set of random variables in the from of linear combinations of another statistically independent component variables. In various useful applications, ICA provides a more meaningful representation of the data than the principal component analysis through the transformation of the data to be quasi-orthogonal to each other. which can be utilized in linear projection.. However, it has been known that ICA does not establish good performance in source separation by itself. Thus, in order to overcome this limitation, there have been many techniques that are designed to reinforce the good properties of ICA, which improves the mixed image separation. Unfortunately, the innovation process still needs to be studied since it yields inconsistent innovation process that is attached to the ICA, the expectation and maximization process is added. The results presented in this paper show that the proposed improves the image separation as presented in experiments.

Extraction of Sizes and Velocities of Spray Droplets by Optical Imaging Method

  • Choo, Yeonjun;Kang, Boseon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1236-1245
    • /
    • 2004
  • In this study, an optical imaging method was developed for the measurements of the sizes and velocities of droplets in sprays. Double-exposure single-frame spray images were captured by the imaging system. An image processing program was developed for the measurements of the sizes and positions of individual particles including separation of the overlapped particles and particle tracking and pairing at two time instants. To recognize and separate overlapping particles, the morphological method based on watershed segmentation as well as separation using the perimeter and convex hull of image was used consecutively. Better results in separation were obtained by utilization of both methods especially for the multiple or heavily-overlapped particles. The match probability method was adopted for particle tracking and pairing after identifying the positions of individual particles and it produced good matching results even for large particles like droplets in sprays. Therefore, the developed optical imaging method could provide a reliable way of analyzing the motion and size distribution of droplets produced by various sprays and atomization devices.