• Title/Summary/Keyword: Image Processor

Search Result 462, Processing Time 0.03 seconds

A Study on Estimation of inner and Wall Pressure Distribution by 3-Dimensional velocity Measurement using PIV (PIV를 이용한 3차원 속도계측에 의한 유동장의 공간 및 벽면압력 분포 추정에 관한연구)

  • 이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.468-480
    • /
    • 1998
  • A flow measurement system which is able to measure the instantaneous three-dimensional velocity components and the pressure distribution of fluid flows is developed using a digital image processing system and the stereoscopic photogrammetry. This system consists of two TV cameras a digital image processor and a 32-bit microcomputer. The capability of the developed system is verified by a preliminary test in which three-dimensional displancements of moving particles arranged on a rotating plate are tracked automatically. The constructed system is through the measurement and spatial pressure distribution is also obtained. The measurement uncertainty of this system is evaluated quantitatively. The present technique is applicable to the measurement of an unsteady fluid phenomenon especially to the measurement of three-dimensional velocity field of a complex flow.

  • PDF

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.470-474
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for inage processing, and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable ad A4 size scanning. and keeps image scan processing speed 300mm/sec. The recognition percentage has 98% on the OCR and bar codes.

IMAGE DATA CHAIN ANALYSIS FOR SATELLITE CAMERA ELECTRONIC SYSTEM

  • Park, Jong-Euk;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Chang, Young-Jun
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.791-793
    • /
    • 2006
  • In the satellite camera, the incoming light source is converted to electronic analog signals by the electronic component for example CCD (Charge Coupled Device) detectors. The analog signals are amplified, biased and converted into digital signals (pixel data stream) in the video processor (A/Ds). The outputs of the A/Ds are digitally multiplexed and driven out using differential line drivers (two pairs of wires) for cross strap requirement. The MSC (Multi-Spectral Camera) in the KOMPSAT-2 which is a LEO spacecraft will be used to generate observation imagery data in two main channels. The MSC is to obtain data for high-resolution images by converting incoming light from the earth into digital stream of pixel data. The video data outputs are then MUXd, converted to 8 bit bytes, serialized and transmitted to the NUC (Non-Uniformity Correction) module by the Hotlink data transmitter. In this paper, the video data streams, the video data format, and the image data processing routine for satellite camera are described in terms of satellite camera control hardware. The advanced satellite with very high resolution requires faster and more complex image data chain than this algorithm. So, the effective change of the used image data chain and the fast video data transmission method are discussed in this paper

  • PDF

Decision Method of Magnetic Domain Walls Using Pixel Value Operation in the Magnetic Domain Image Observed by Kerr Microscopy (자기광학현미경으로부터 관찰한 자구모양의 픽셀값 연산을 이용한 자벽선 결정방법)

  • Kim, Young-Hak
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.1
    • /
    • pp.35-40
    • /
    • 2017
  • Kerr microscopy was assembled to observe magnetic domain image of ultra thin 3 %Si-Fe by using parts of an optical microscope. Digital images were obtained from CCD camera attached to the microscopy. A method was suggested to decide a boundary between magnetic domain regions in this study. The method was using some operations such as subtraction, integration and least mean square approximation for pixel values in the digital image. The method has a strong point that high priced image processor is not needed in the Kerr microscopy system. From the results that three different domain walls were observed and magnetic flux density of 0.085 [T], this method could be applied in the magnetic domain regions having a straight $180^{\circ}$ domain wall.

Efficient Transformations Between an $n^2$ Pixel Binary Image and a Boundary Code on an $n^3$ Processor Reconfigurable Mesh ($n^3$ 프로세서 재구성가능 메쉬에서 $n^2$ 화소 이진영상과 경계코드간의 효율적인 변환)

  • Kim, Myung
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.8
    • /
    • pp.2027-2040
    • /
    • 1998
  • In this paper, we present efficient reconfigurable mesh algorithms for transforming between a binary image and its corresponding boundary code. These algorithms use $n\timesn\timesn$ processors when the size of the binary image is $n\timesn$. Recent published results show that these transformations can be done in O(1) time using $O(n^4)$ processors. The number of processors used by these algorithms is very large compared to the number of pixels in the image. Here, we present fast transformation algorithms which use $n^3 processors only. the transformation from a houndary code to a binary image takes O(1) time, and the converse transformation takes O(log n) time.

  • PDF

On Post-Processing of Coded Images by Using the Narrow Quantization Constraint (협 양자화 제약 조건을 이용한 부호화된 영상의 후처리)

  • 박섭형;김동식;이상훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.648-661
    • /
    • 1997
  • This paper presents a new method for post-processing of coded images based upon the low-pass filtering followed by the projection onto the NQCS (narrow quantization constraint set). We also investigate how the proposed method works on JPEG-coded real images. The starting point of the QCS-based post-processing techniques is the centroid of the QCS, where the original image belongs. The low-pass filtering followed by the projection onto the QCS makes the images lie on the boundary of the QCS. It is likely that, however, the original image is inside the QCS. Hence projection onto the NQCS gives a lower MSE (mean square error) than does the projection onto the QCS. Simulation results show that setting the narrowing coefficients of the NQCS to be 0.2 yields the best performance in most cases. Even though the JPEG-coded image is low-pass filtered and projected onto the NQCS repeatedly, there is no guarantee that the resultant image has a lower MSE and goes closer to the original image. Thus only one iteration is sufficient for the post-processing of the coded images. This is interesting because the main drawback of the iterative post-processing techniques is the heavy computational burden. The single iteration method reduces the computational burden and gives us an easy way to implement the real time VLSI post-processor.

  • PDF

Control Unit Design and Implementation for SIMD Programmable Unified Shader (SIMD 프로그래머블 통합 셰이더를 위한 제어 유닛 설계 및 구현)

  • Kim, Kyeong-Seob;Lee, Yun-Sub;Yu, Byung-Cheol;Jung, Jin-Ha;Choi, Sang-Bang
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.7
    • /
    • pp.37-47
    • /
    • 2011
  • Real picture like high quality computer graphic is widely used in various fields and shader processor, a key part of a graphic processor, has been advanced to programmable unified shader. However, The existing graphic processors have been optimized to commercial algorithms, so development of an algorithm which is not based on it requires an independent shader processor. In this paper, we have designed and implemented a control unit to support high quality 3 dimensional computer graphic image on programmable integrated shader processor. We have done evaluation through functional level simulation of designed control unit. Hardware resource usage rate are measured by implementing directly on FPGA Virtex-4 and execution speed are verified by applying ASIC library. the result of an evaluation shows that the control unit has the commands more about 1.5 times compared to the other shader processors that is a behavior similar to the control unit and with a number of processing units used in a shader processor, compared with the other processors, overall performance of the control unit is improved about 3.1 GFLOPS.

A Study on the high-speed Display of Radar System Positive Afterimage using FPGA and Dual port SRAM (FPGA와 Dual Port SRAM 적용한 Radar System Positive Afterimage 고속 정보 표출에 관한 연구)

  • Shin, Hyun Jong;Yu, Hyeung Keun
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • This paper was studied in two ways with respect to the information received from the video signal separation technique of PPI Scop radar device. The proposed technique consists in generating an image signal through the video signal separation and synthesis, symbol generation, the residual image signal generation process. This technology can greatly improve the operating convenience with improved ease of discrimination, screen readability for the operator in analyzing radar information. The first proposed method was constructed for high-speed FPGA-based information processing systems for high speed operation stability of the system. The second proposed method was implemented intelligent algorithms and a software algorithm function curve associated resources.This was required to meet the constraints on the radar information, analysis system. Existing radar systems have not the frame data analysis unit image. However, this study was designed to image data stored in the frame-by-frame analysis of radar images with express information MPEG4 video. Key research content is to highlight the key observations expresses the target, the object-specific monitoring information to the positive image processing algorithm and the function curve delays. For high-definition video, high-speed to implement data analysis and expressing a variety of information was applied to the ARM Processor Support in Pro ASIC3.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

A Study on the Characteristics by Image Type in Interior Color using HAYASI 1 Program (수량화 1 류 분석을 이용한 실내색채의 이미지 유형별 특성연구)

  • 이진숙;서정원;조원덕;이선희
    • Korean Institute of Interior Design Journal
    • /
    • no.7
    • /
    • pp.31-37
    • /
    • 1996
  • The purpose of this study is to grasp the characteristics by image type in interior color. This experiment is carried out by the evaluation method of color simulation with the color image processor. And the result of this experimental evaluation is analyzed quantitatively by HAYASI 1 Program. The results of this analysis are as follows : 1) In casual and clear images, the most main colors are GY, PB, Y , and N, Casual image has high chroma and the most arrangement of colors is hue-contrast or contrast -harmony with white. Also the main colors of clear image are in identical or similar harmony with the hues of floor. 2) In romantic, elegant, pretty, and gorgeous images, the most main colors are GY, RP, R , YR and Y and the most arrangement of colors is identical or similar harmony. The romantic image of pastel tone is wholly lighter than the pretty image of bright tone. And elegant image is lower in chroma than romantic images, so generally dark. Also gorgeous image is the vivid tone with high chroma. 3) In chic and modern images, the main colors are the hues of B, PB, high value and low chroma with bright tone. Also, the main colors are in identical or similar harmony with the hues of floor : BG , B, PB and P. 4) In natural and semiclassic images, the main color is the warm color of Y, YR and the most arrangement of colors is identical or similar harmony. Also Semiclassic images is the dull tone with middle value and middle chroma and darker tone than natural image. 5) In dynamic image, the main color is the hue of N, Y, PB and GY and most of color is high chroma. And the most arrangement of colors is value-contrast.

  • PDF