• Title/Summary/Keyword: Image Board

Search Result 581, Processing Time 0.034 seconds

The Far-ultraviolet Spectrum Study of Comet C/2001 Q4 (NEAT)

  • Lim, Yeo-Myeong;Min, Kyoung-Wook;Feldman, Paul D.;Han, Wanyong;Edelstein, Jerry
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.68.1-68.1
    • /
    • 2014
  • We present the results of far-ultraviolet (FUV) observations of comet C/2001 Q4 (NEAT) obtained with Far-ultraviolet Imaging Spectrograph (FIMS) on board the Korean microsatellite STSAT-1, which operated at an altitude of 700 km in a sun-synchronous orbit. FIMS is a dual channel imaging spectrograph (S-channel 900-1150 ${\AA}$, L-channel 1350-1710 ${\AA}$, and ${\lambda}/{\Delta}{\lambda}$ ~ 550 for both channels) with large image fields of view (S-channel $4.0^{\circ}{\times}4.6^{\prime}$, L-channel $7.5^{\circ}{\times}4.3^{\prime}$, and angular resolution ~ $5-10^{\prime}$) optimized for the observation of diffuse emission of astrophysical radiation. Comet C/2001 Q4 (NEAT) were made in two campaigns during its perihelion approach between May 8 and 15, 2004. Based on the scanning mode observations in the wavelength band of 1400-1700 ${\AA}$, we have constructed an image of the comet with an angular size of $5^{\circ}{\times}5^{\circ}$, which corresponds to the central coma region. Several important fluorescence emission lines were detected including S I multiplets at 1429 and 1479 ${\AA}$, C I multiplets at 1561 and 1657 ${\AA}$, and the CO $A^1{\Pi}-X^1{\Sigma}^+$ Fourth Positive system; we have estimated the production rates of the corresponding species from the fluxes of these emission lines. The estimated production rate of CO was $Q_{CO}=(2.65{\pm}0.63){\times}10^{28}s^{-1}$, which is 6.2-7.4% of the water production rate and is consistent with earlier predictions. The average carbon production rate was estimated to be $Q_C={\sim}1.59{\times}10^{28}s^{-1}$, which is ~60% of the CO production rate. However, the observed carbon profile was steeper than that predicted using the two-component Haser model in the inner coma region, while it was consistent with the model in the outer region. The average sulfur production rate was $Q_S=(4.03{\pm}1.03){\times}10^{27}s^{-1}$, which corresponds to ~1% of the water production rate.

  • PDF

Development of Imaging Gamma Probe Using the Position Sensitive PMTube (위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;So, Su-Gil;Kim, Han-Myeong;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • The purpose of this study was to develop a miniature imaging gamma probe with high performance that can detect small or residual tumors after surgery. Gamma probe detector system consists of NaI(Tl) scintillator, position sensitive photomultiplier tube (PSPMT), and collimator. PSPMT was optically coupled with 6.5 mm thick, 7.62 cm diameter of NaI(Tl) crystal and supplied with -1000V for high voltage. Parallel hexagonal hole collimator was manufactured for characteristics of 40-mm hole length, 1.3-mm hole diameter, and 0.22 mm septal thickness. Electronics consist of position and trigger signal readout systems. Position signals were obtained with summing, subtracting, and dividing circuit using preamplifer and amplifier. Trigger signals were obtained using summing amplifier, constant fraction discriminator, and gate and delay generator module with preamplifer. Data acquisition and processing were performed by Gamma-PF interface board inserted into pentium PC and PIP software. For imaging studies, flood and slit mask images were acquired using a point source. Two hole phantom images were also acquired with collimator. Intrinsic and system spatial resolutions were measured as 3.97 mm and 5.97 mm, respectively. In conclusion, Miniature gamma probe images based on the PSPMT showed good image quality, we conclude that the miniature imaging gamma probe was successfully developed and good image data were obtained. However, further studies will be required to optimize imaging characteristics.

  • PDF

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Current Status and Results of In-orbit Function, Radiometric Calibration and INR of GOCI-II (Geostationary Ocean Color Imager 2) on Geo-KOMPSAT-2B (정지궤도 해양관측위성(GOCI-II)의 궤도 성능, 복사보정, 영상기하보정 결과 및 상태)

  • Yong, Sang-Soon;Kang, Gm-Sil;Huh, Sungsik;Cha, Sung-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1235-1243
    • /
    • 2021
  • Geostationary Ocean Color Imager 2 (GOCI-II) on Geo-KOMPSAT-2 (GK2B)satellite was developed as a mission successor of GOCI on COMS which had been operated for around 10 years since launch in 2010 to observe and monitor ocean color around Korean peninsula. GOCI-II on GK2B was successfully launched in February of 2020 to continue for detection, monitoring, quantification, and prediction of short/long term changes of coastal ocean environment for marine science research and application purpose. GOCI-II had already finished IAC and IOT including early in-orbit calibration and had been handed over to NOSC (National Ocean Satellite Center) in KHOA (Korea Hydrographic and Oceanographic Agency). Radiometric calibration was periodically conducted using on-board solar calibration system in GOCI-II. The final calibrated gain and offset were applied and validated during IOT. And three video parameter sets for one day and 12 video parameter sets for a year was selected and transferred to NOSC for normal operation. Star measurement-based INR (Image Navigation and Registration) navigation filtering and landmark measurement-based image geometric correction were applied to meet the all INR requirements. The GOCI2 INR software was validated through INR IOT. In this paper, status and results of IOT, radiometric calibration and INR of GOCI-II are analysed and described.

Development of a Multi-Camera Inline System using Machine Vision System for Quality Inspection of Pharmaceutical Containers (의약 용기의 품질 검사를 위한 머신비전을 적용한 다중 카메라 인라인 검사 시스템 개발)

  • Tae-Yoon Lee;Seok-Moon Yoon;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.28 no.3
    • /
    • pp.469-473
    • /
    • 2024
  • In this paper proposes a study on the development of a multi-camera inline inspection system using machine vision for quality inspection of pharmaceutical containers. The proposed technique captures the pharmaceutical containers from multiple angles using several cameras, allowing for more accurate quality assessment. Based on the captured data, the system inspects the dimensions and defects of the containers and, upon detecting defects, notifies the user and automatically removes the defective containers, thereby enhancing inspection efficiency. The development of the multi-camera inline inspection system using machine vision is divided into four stages. First, the design and production of a control unit that fixes or rotates the containers via suction. Second, the design and production of the main system body that moves, captures, and ejects defective products. Third, the design and development of control logic for the embedded board that controls the entire system. Finally, the design and development of a user interface (GUI) that detects defects in the pharmaceutical containers using image processing of the captured images. The system's performance was evaluated through experiments conducted by a certified testing agency. The results showed that the dimensional measurement error range of the pharmaceutical containers was between -0.30 to 0.28 mm (outer diameter) and -0.11 to 0.57 mm (overall length), which is superior to the global standard of 1 mm. The system's operational stability was measured at 100%, demonstrating its reliability. Therefore, the efficacy of the proposed multi-camera inline inspection system using machine vision for the quality inspection of pharmaceutical containers has been validated.

Characteristics of the Electro-Optical Camera(EOC) (다목적실용위성탑재 전자광학카메라(EOC)의 성능 특성)

  • Seunghoon Lee;Hyung-Sik Shim;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.213-222
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of the KOrea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including a Digital Terrain Elevation Map(DTEM). This instalment which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510~730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response, the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the users of EOC data. The modulation transfer function of EOC was measured as greater than 16 % at Nyquist frequency over the entire field of view, which exceeds its requirement of larger than 10 %. The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

A Study on the Meaning and Cultural Properties Value of Rock-Go-Board from the Viewpoint of Site and Location Characteristics (입지와 장소 특성으로 본 암각바둑판의 의미와 문화재적 가치)

  • Park, Joo Sung;Rho, Jae Hyun;Sim, Woo Kyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.172-205
    • /
    • 2011
  • Go bears significant meanings in terms of cultural and entertaining functions in Asia Eastern such as China and Japan. Beyond the mere entertaining level, it produces philosophical and mythic discourse as well. As a part of effort to seek an identity of Korean traditional garden culture, this study traced back to find meanings of rock-go-board and taste for the arts which ancestors pursued in playing Go game, through analysis and interpretation of correlation among origin of place name, nearby scenery, carved letters and vicinal handed-down place name. At the same time, their position, shape and location types were interpreted through comprehensive research and analysis of stone-go-boards including rock-go-board. Particularly, it focused on the rock names related to Sundoism(仙道) Ideal world, fixed due to a connection between traces of Sundoism and places in a folk etymology. Series of this work is to highlight features of the immortal sceneries, one of traditional landscaping ideals, by understanding place identity and scenic features of where the rock-go-boards are carved. These works are expected to become foundation for promotion and preservation of the traditional landscaping remains. The contents of this study could be summarized as follows; First, round stone and square board for round sky and angled land, black and white color for harmony of yin and yang and 361paths for rotating sky are symbols projecting order of universe. Sayings of Gyuljungjirak(橘中之樂), Sangsansaho(商山四皓), Nangagosa(爛柯故事) formed based on the idea of eternity stand for union of sky and sun. It indicates Go game which matches life and nature spatiotemporally and elegant taste for arts pursuing beauty and leisure. Second, the stone-go-boards found through this research, are 18 in total. 3 of those(16.1%), Gangjin Weolnamsaji, Yangsan Sohanjeong and Banryongdae ones were classified into movable Seokguk and 15(83.9%) including Banghakdong were turned out to be non-movable rock-go-boards carved on natural rocks. Third, upon the result of materializing location types of rock-go-boards, 15 are mountain stream type(83.9%) and 3 are rock peak type(16.1%). Among those, the one at Sobaeksam Sinseonbong is located at the highest place(1,389m). Considering the fact that all of 15 rock-go-boards were found at mountainous areas lower than 500m, it is recognizable that where the Go-boards are the parts of the living space, not far from secular world. Fourth, there are 7 Sunjang(巡將) Go with 17 Hwajeoms(花點), which is a traditional Go board type, but their existences, numbers and shapes of Hwajeom appear variously. Based on the fact, it is recognizable that culture of making go-board had been handed down for an extended period of time. Among the studied rock-goboards, the biggest one was Muju Sasunam[$80(82)cm{\times}80(82)cm$] while the smallest one was Yangsan Sohandjeong Seokguk ($40cm{\times}40cm$). The dimension of length and breadth are both $49cm{\times}48cm$ on average, which is realistic size for actual Go play. Fifth, the biggest bed rock, an under-masonry with carved Go-board on it, was one in Muju Sasunam[$8.7m{\times}7.5m(65.25m^2)$], followed by ones in Hoengseong Chuiseok[$7.8m{\times}6.3m(49.14m^2$] and Goisan Sungukam[$6.7m{\times}5.7m(37.14m^2)$]. Meanwhile, the smallest rock-go-board was turned out to be one in Seoul Banghak-dong. There was no consistency in directions of the Go-boards, which gives a hint that geographical features and sceneries of locations were considered first and then these were carved toward an optimal direction corresponding to the conditions. Sixth, rock-go-boards were all located in valleys and peaks of mountains with breathtaking scenery. It seems closely related to ancestors' taste for arts. Particularly, rock-go-boards are apprehended as facilities related to taste for arts for having leisure in many mountains and big streams under the idea of union of sky and human as a primitive communal line. Go became a medium of hermits, which is a traditional image of Go-game, and symbol of amusement and entertainment with the idea that Go is an essence of scholar culture enabling to reach the Tao of turning back to nature. Seventh, the further ancient time going back to, the more dreamlike the Go-boards are. It is an evident for that Sundoism, which used to be unacceptable once, became more visible and realistic. Considering the high relation between rock-go-boards and Sundoism relevant names such as Sundoism peak in Danyang Sobaeksan, 4 hermits rock in Muju and Sundoism hermit rock in Jangsu, Sundoism hermit rocks and rock-go-boards are sceneries and observation spots to express a communication of worship and longing for Sundoism. Eighth, 3 elements-physical environment such as location type of the rock-go-boards, human activities concentrated on 8 sceneries and Dongcheongugok(洞天九曲) setup and relevancy to Confucian scholars, as well as 'Sangsansaho' motif and 'Nangagosa' symbolic meaning were used as interpretation tools in order to judge the place identity. Upon the result, spatial investigation is required with respect to Sunyoodongcheon(仙遊洞天) concept based on enjoyment to unify with the nature rather than Dongcheongugok concept of neo-Confucian, for Dongcheon and Dongmoon(洞門) motives carved around the rock-go-boards. Generally, places where mountain stream type rock-go-boards were formed were hermit spaces of Confucianism or Sundoism. They are considered to have compromised one other with the change of times. Particularly, in the rock-go-board at the mountain peak, sublimity-oriented advent of Sundoism is considered as a significant factor to control place identity. Ninth, including where the rock-go-boards were established, the vicinal areas are well-known as parts of Dongcheongugok and Palkyung(八景) mostly. In addition, many of Sundoism relevant expressions were discovered even in the neighboring carvings written by scholars and nobility, which means sophisticated taste based on longing for Sundoism world played a significant role in making go-board. The rock-go-board is an integration of cultural phenomena naturally managed by seclusion of scholars in the Joseon Dynasty as well as remains and essence of Korean traditional landscaping. Some rock-go-boards out of 17 discovered in South Korea, including ones in Sobaeksan Sinsunbong, Banghak-dong, Chungju Gongili, Muju Sasunam, Yangsan Eogokdong Banryongdae Seokguk, are damaged such as cracks in rocks or fainted lines by hardships of time and hand stains. Worse yet, in case of Eunyang Bangudae Jipcheongjeong board, it is very difficult to identify the shape due to being buried. Rock-go-boards are valuable sculptures in terms of cultural asset and artwork since they reflect ancestors' love for nature and longing for Sundoism world. Therefore, they should be maintained properly with right preservation method. Not only rock-boards itself but also peripheral places are excellent cultural heritages and crucial cultural assets. In addition, vicinal sceneries of where rock-goboards and pavilion spots are the representative remains of embracing prototype of Korean traditional landscaping and major parts of cultural properties.

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)