• Title/Summary/Keyword: Image Blurring

Search Result 310, Processing Time 0.027 seconds

Human Factor Research on the Measurement of Subjective Three Dimensional Fatigue (주관적인 3차원 피로감 측정 방법에 대한 휴먼팩터 연구)

  • Li, Hyung-Chul O.
    • Journal of Broadcast Engineering
    • /
    • v.15 no.5
    • /
    • pp.607-616
    • /
    • 2010
  • The methods developed to measure visual fatigue so far are quite few and lack of validity, and more importantly, they do not figure out the complex properties of the visual fatigue. The purpose of the research was to analyze the factors comprising the visual fatigue and to develop the method to measure it validly. The results are summarized as follows. First, we found that the 3D visual fatigue was comprised of four independent factors (visual stress, eye pain, body pain and image blurring factors). Second, we developed 29 items that measure four factors of 3D visual fatigue. Finally, the watching duration and binocular disparities affected the visual fatigue as had been expected. These results imply that the developed method does measure the three dimensional fatigue validly.

An Experimental Study of the Synthetic Sinc Wave in Ultrasonic Imaging (초음파 의료 영상에서 합성 Sinc 음장 집속방법의 실험적 고찰)

  • 이광주;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.243-251
    • /
    • 2002
  • Synthetic zinc wave employs Pulsed plane wave as transmit beam with linear time delay curve. The received echoes in different transmit directions at different transmit times are superposed at imaging Points with Proper time delay compensation using synthetic focusing scheme. This scheme. which uses full aperture in transmit, obtains a high SNR image, and also features high lateral resolution by using two way dynamic focusing at all imaging depths. In this Paper, we consider the Problems in realization of synthetic zinc wave. Also. we have applied the scheme to obtain phantom and in-vivo images using a linear array of 5 MHz. In phantom test. experimental images show high resolution over a more extended imaging depth than conventional fixed Point transmit and receive dynamic focusing schemes In-vivo images show that the resolution could not overcome conventional focusing systems because of motion blurring and(or) aberration of tissue. but the frame rate tan be increased by a factor of more than 5 compared to conventional focusing schemes. with competitive resolution at all imaging depths .

A Study on the Rotational Motion Compensation Method for ISAR Imaging (ISAR 영상 형성을 위한 회전운동보상 기법 연구)

  • Kang, Byung-Soo;Bae, Ji-Hoon;Chung, Sung-Eun;Kim, Chan-Hong;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • In this paper, we propose a inverse synthetic aperture radar(ISAR) rotational motion compensation(RMC) method to remove residual blurring caused by non-uniform rotational motion of a target. First, a range bin having an isolated scatterer is selected. Next, polynomial phase signal in the selected range bin is estimated by using both Fourier transform(FT) and polynomial-phase transform(PPT). Finally, a new slow time variable that uniformly samples radar signal along the aspect angle directions is defined by using the estimated phase signal, and we interpolate radar signal in terms of the new time variable. As a result, rotational motion to blurr ISAR images is removed, and focused ISAR images are obtained. Simulation results using battleship model validate the robustness and effectiveness of our proposed RMC method.

The Response Characteristics of as Addition Ratio of Arsenic in $CaWO_4/a-Se$ based X-ray Conversion Sensor ($CaWO_4/a-Se$ 구조의 X선 변환센서에서 a-Se의 Arsenic 첨가량에 따른 반응 특성)

  • Kang, Sang-Sik;Suk, Dae-Woo;Cho, Sung-Ho;Kim, Jae-Hyung;Nam, Namg-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.416-419
    • /
    • 2002
  • There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. The one is using amorphous selenium as photoconductor and the other is using phosphor layer as a light conversion. But each two systems have strength and weakness such as high voltage and blurring effect. In this study, we investigated the electrical characteristic of $multi-layer\left(CaWO_{4}+a-Se \right)$ as a photoconductor according to the changing arsenic composition ratio. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. The arsenic composition ratio of a-Se compound is classified into 7 different kinds which have 0.1%, 0.3%, 0.5%, 1%, 1.5%, 5%, 10% and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 0.3% arsenic showed good characteristic of $2.45nA/cm^2$ dark current and $357.19pC/cm^2/mR$ net charge at $3V/{\mu}m$.

  • PDF

An Adaptive De-blocking Algorithm in Low Bit-rate Video Coding (저 비트율 비디오를 위한 적응적 블록킹 현상 제거 기법)

  • 김종호;김해욱;정제창
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.505-513
    • /
    • 2004
  • Most video codecs including the international standards use the block-based hybrid structure for efficient compression. But for low bit-rate applications such as video transmission through wireless channels, the blocking artifacts degrade image qualify seriously. In this paper, we propose an adaptive de-blocking algorithm using characteristics of the block boundaries. Blocking artifacts contain the high frequency components near the block boundaries, therefore the lowpass filtering can remove them. However, simple lowpass filtering results into blurring by removing important information such as edges. To overcome this problem, we determine the modes depending upon the characteristics of pixels adjacent to block boundary then proper filter is applied to each area. Simulation results show that proposed method improves de-blocking performance compared to that of MPEG-4.

A Single Camera based Method for Cubing Rectangular Parallelepiped Objects (한대의 카메라에 기반한 직육면체의 부피 계측 방법)

  • Won, Jong-Won;Chung, Yun-Su;Kim, Woo-Seob;You, Kwang-Hun;Lee, Yong-Joon;Park, Kil-Houm
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.5
    • /
    • pp.562-573
    • /
    • 2002
  • In this paper, we propose a method for measuring the volume of packages for the efficient handling of the packages. Using the geometrical characteristics of the rectangular parallelepiped type objects, the method measures the volume of packages with one camera only in real time. In preprocessing of volume measurement, the method extracts outer lines of the object and then crossing points of the lines as feature points or vertexes. From these cross points(-feature points-), the volume of the package is calculated. Compared to the direct feature extraction, the proposed method shows especially the blurring robust result by using the line for feature extraction. Additionally, the method can get the stable result by considering object's direction. From experimental results, it is demonstrated that this method is very effective for the real time volume measurement of the rectangular parallelepiped.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

A Novel Video Copy Detection Method based on Statistical Analysis (통계적 분석 기반 불법 복제 비디오 영상 감식 방법)

  • Cho, Hye-Jeong;Kim, Ji-Eun;Sohn, Chae-Bong;Chung, Kwang-Sue;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.14 no.6
    • /
    • pp.661-675
    • /
    • 2009
  • The carelessly and illegally copied contents are raising serious social problem as internet and multimedia technologies are advancing. Therefore, development of video copy detection system must be settled without delay. In this paper, we propose the hierarchical video copy detection method that estimates similarity using statistical characteristics between original video and manipulated(transformed) copy video. We rank according to luminance value of video to be robust to spacial transformation, and choose similar videos categorized as candidate segments in huge amount of database to reduce processing time and complexity. The copy videos generally insert black area in the edge of the image, so we remove rig black area and decide copy or not by using statistical characteristics of original video and copied video with center part of frame that contains important information of video. Experiment results show that the proposed method has similar keyframe accuracy to reference method, but we use less memory to save feature information than reference's, because the number of keyframes is less 61% than that of reference's. Also, the proposed method detects if the video is copied or not efficiently despite expansive spatial transformations such as blurring, contrast change, zoom in, zoom out, aspect ratio change, and caption insertion.

Performance Analysis of Matching Cost Functions of Stereo Matching Algorithm for Making 3D Contents (3D 콘텐츠 생성에서의 스테레오 매칭 알고리즘에 대한 매칭 비용 함수 성능 분석)

  • Hong, Gwang-Soo;Jeong, Yeon-Kyu;Kim, Byung-Gyu
    • Convergence Security Journal
    • /
    • v.13 no.3
    • /
    • pp.9-15
    • /
    • 2013
  • Calculating of matching cost is an important for efficient stereo matching. To investigate the performance of matching process, the concepts of the existing methods are introduced. Also we analyze the performance and merits of them. The simplest matching costs assume constant intensities at matching image locations. We consider matching cost functions which can be distinguished between pixel-based and window-based approaches. The Pixel-based approach includes absolute differences (AD) and sampling-intensitive absolute differences (BT). The window-based approach includes the sum of the absolute differences, the sum of squared differences, the normalized cross-correlation, zero-mean normalized cross-correlation, census transform, and the absolute differences census transform (AD-Census). We evaluate matching cost functions in terms of accuracy and time complexity. In terms of the accuracy, AD-Census method shows the lowest matching error ratio (the best solution). The ZNCC method shows the lowest matching error ratio in non-occlusion and all evaluation part. But it performs high matching error ratio at the discontinuities evaluation part due to blurring effect in the boundary. The pixel-based AD method shows a low complexity in terms of time complexity.

Sharpness Evaluation of UAV Images Using Gradient Formula (Gradient 공식을 이용한 무인항공영상의 선명도 평가)

  • Lee, Jae One;Sung, Sang Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.1
    • /
    • pp.49-56
    • /
    • 2020
  • In this study, we analyzed the sharpness of UAV-images using the gradient formula and produced a MATLAB GUI (Graphical User Interface)-based sharpness analysis tool for easy use. In order to verify the reliability of the proposed sharpness analysis method, sharpness values of the UAV-images measured by the proposed method were compared with those by measured the commercial software Metashape of the Agisoft. As a result of measuring the sharpness with both tools on 10 UAV-images, sharpness values themselves were different from each other for the same image. However, there was constant bias of 011 ~ 0.20 between two results, and then the same sharpness was obtained by eliminating this bias. This fact proved the reliability of the proposed sharpness analysis method in this study. In addition, in order to verify the practicality of the proposed sharpness analysis method, unsharp images were classified as low quality ones, and the quality of orthoimages was compared each other, which were generated included low quality images and excluded them. As a result, the quality of orthoimage including low quality images could not be analyzed due to blurring of the resolution target. However, the GSD (Ground Sample Distance) of orthoimage excluding low quality images was 3.2cm with a Bar target and 4.0cm with a Siemens star thanks to the clear resolution targets. It therefore demonstrates the practicality of the proposed sharpness analysis method in this study.