• Title/Summary/Keyword: Image Artifacts Reduction

Search Result 88, Processing Time 0.025 seconds

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

An Improved Design Method of FIR Quadrature Mirror-Image Filter Banks (개선된 FIR QMF 뱅크의 설계 방법)

  • 조병모;김영수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.213-221
    • /
    • 2004
  • A new method for design of two-channel finite-impulse response(FIR) quadrature mirror-image filter(QMF) banks with low reconstruction delay using weighting function is proposed. The weighting function used in this paper is calculated from the previous updated filter coefficients vector which is adjusted from iteration to iteration in the design of QMF banks. In this paper, passband and stopband edge frequency are used in design of QMF banks with low delay characteristic in time domain instead of specific frequency interval where the artifacts occur in conventional design method. The investigation of specific frequency interval where artifacts occur can not be required by using passband and stopband edge frequency. Some comparisons of performance are made with other existing design method to demonstrate the proposed method for QMF bank design. and it was observed that the proposed method using the weighted function and passband and stopband edge frequency improves the peak reconstruction error by 0.001 [dB], the peak-to-peak passband ripple by 0.003[dB], SNR with a white noise by 7[dB] and SNR with a step input by 32[dB], but with a reduction of the computational efficiency because of updating the weighting function over the conventional method in Ref [11].

Modifcation of Reconstruction Filter for Low-Dose Reconstruction (저조사광 재구성을 위한 필터 설계)

  • 염영호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 1980
  • The reconstruction problem in a low dose case requires some compromise of resolution and noise artifacts, and also some modification of filter kernels depending on the signal-to-noise ratio of projection data. In this paper, ail algorithm for the reconstruction of an image function from noisy projection data is suggested, based on minimum-mean-square error criterion. Modification of the falter kernel is made from information (statistics) obtained from the projection data. The simulation study Proves that this algorithm, based on the Wiener falter approach, provides substantially improved image with reduction of noise as well as improvement of the resolution. An approximate method was also studied which leads to the possible use of a recursive filter in the convolution process of image reconstruction.

  • PDF

Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2 (DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교)

  • Choi, Na-Rae;Nam, Yoon-Ho;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2010
  • Purpose : DIR image is relatively free from susceptibility artifacts therefore, DIR image can make it possible to reliably measure cortical thickness/volume. One drawback of the DIR acquisition is the long scan time to acquire the fully sampled 3D data set. To solve this problem, we applied a parallel imaging method (GRAPPA) and verify the reliability of using the volumetric study. Materials and methods : Six healthy volunteers (3 males and 3 females; age $25.33{\pm}2.25$ years) underwent MRI using the 3D DIR sequence at a 3.0T Siemens Tim Trio MRI scanner. GRAPPA simulation was performed from the fully sampled data set for reduction factor 2. Data reconstruction was performed using MATLAB R2009b. Freesurfer v.4.3.0 was used to evaluate the cortical thickness of the entire brain, and to extract white matter information from the DIR image, Analyze 9.0 was used. The global cortical thickness estimated from the reconstructed image was compared with reference image by using a T-test in SPSS. Results : Although reduced SNR and blurring are observed from the reconstructed image, in terms of segmentation the effect was not so significant. The volumetric result was validated that there were no significant differences in many cortical regions. Conclusion : This study was performed with DIR image for a volumetric MRI study. To solve the long scan time of 3D DIR imaging, we applied GRAPPA algorithm. According to the results, fast imaging can be done with reduction factor 2 with little loss of image quality at 3.0T.

Crosstalk Reduction of Glasses-free 3D Displays using Multiview Image Processing (다시점 영상처리를 이용한 무안경 3차원 디스플레이의 크로스톡 저감 방법)

  • Kim, Sung-Yeol;Lee, Jin-Sung;Choi, Sang Mi
    • Journal of Broadcast Engineering
    • /
    • v.21 no.1
    • /
    • pp.66-75
    • /
    • 2016
  • In this paper, we present a new method to reduce crosstalk of a glasses-free three-dimensional (3D) display using a multi-view image processing technique. Since crosstalk makes the current view image mixed with its neighboring ones, the output 3D image becomes severely blurred. We apply adaptive depth retargeting and view gradient-based crosstalk inverse filtering onto a multi-view image to minimize crosstalk of the glasses-free 3D display. In addition, overflow and underflow pixels are compensated by epipolar image pixel interpolation so that visual artifacts are minimized. Experimental results show that the proposed method reduces crosstalk more efficiently than the previous work while improving 3D image quality.

IMPROVING DEBLOCKING ALGORITHMS BY USING STEP RESPONSE OF LPE IN THE LOW ACTIVITY REGION

  • Kwak, Jung-Won;Cho, Nam-Ik
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.109-112
    • /
    • 2000
  • An algorithm for the reduction of blocking artifacts is pro-posed. Instead of filtering the pixels by a digital filter, the proposed algorithm considers the compressed image as continuous-time ,signal and replaces it by a pre-designed lowpass filter outputs. The algorithm shows better performance than the conventional methods in low activity region, and comparable or a little worse objective performance in high activity region. Hence, by applying the proposed algorithm to the low activity region and the conventional ones to the high activity region, the objective and subjective performances are improved in most cases.

  • PDF

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.

Multitoning Method Based on Arrangement of Ink Distribution for Smooth Tone Transition (부드러운 계조 변화를 위한 잉크 분포 조절 기반의 멀티토닝 방법)

  • Park, Tae-Yong;Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.17-25
    • /
    • 2007
  • Multilevel inkjet printer employs multiple ink droplets with variable dot size and/or different concentrations intended to preserve high fidelity color reproduction and the appearance of continuous tone. A variety of research efforts on multitoning techniques has progressed toward better image quality. However, banding artifacts appear due to the same dot distributions near the printable output levels. This results in discontinuity and visually unpleasing output, especially at the smooth tone transition region. In this paper, to reduce the banding artifacts, a multitoning method to arrange ink distribution by controlling the blending proportion of adjacent output pixels based on an improved threshold scaling function is proposed. Ink distributions across the banding regions are changed according to two factors of the threshold scaling function because these factors handle the blending point of adjacent output pixel. Therefore, 8 observers, subjectively investigated ink distributions around the printable output levels for a set of the improved threshold scaling function. For a threshold scaling function with the specific factor values, we can achieve smoother visual transition. In the experiment, the proposed method showed a reduction of banding artifacts in both u-ay and color image and represented better Performance of color reproduction.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

Quantization Noise Reduction in Block-Coded Video Using the Characteristics of Block Boundary Area (블록 경계 영역 특성을 이용한 블록 부호화 영상에서의 양자화 잡음 제거)

  • Kwon Kee-Koo;Yang Man-Seok;Ma Jin-Suk;Im Sung-Ho;Lim Dong-Sun
    • The KIPS Transactions:PartB
    • /
    • v.12B no.3 s.99
    • /
    • pp.223-232
    • /
    • 2005
  • In this paper, we propose a novel post-filtering algorithm with low computational complexity that improves the visual quality of decoded images using block boundary classification and simple adaptive filter (SAF). At first, each block boundary is classified into smooth or complex sub-region. And for smooth-smooth sub-regions, the existence of blocking artifacts is determined using blocky strength. And simple adaptive filtering is processed in each block boundary area. The proposed method processes adaptively, that is, a nonlinear 1-D 8-tap filter is applied to smooth-smooth sub-regions with blocking artifacts, and for smooth-complex or complex-smooth sub-regions, a nonlinear 1-D variant filter is applied to block boundary pixels so as to reduce the blocking and ringing artifacts. And for complex-complex sub-regions, a nonlinear 1-D 2-tap filter is only applied to adjust two block boundary pixels so as to preserve the image details. Experimental results show that the proposed algorithm produced better results than those of conventional algorithms both subjective and objective viewpoints.