• Title/Summary/Keyword: Illumination system

Search Result 1,044, Processing Time 0.032 seconds

A Development of the Side Inspection System for A Circularity Using 8 Side Mirrors Method (8각 미러에 의한 원형제품의 측면검사시스템 개발)

  • Lee, Kyu-Hun;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.56-63
    • /
    • 2008
  • In this study, a side inspection system for circular o-ring, bolt, plastic and gasket using 8 side mirrors has been developed. The system is comprised of a CCD camera, an illumination, the first 8 mirrors and the second 8 mirrors, and moreover the image processing algorithm for detecting three different type samples is developed. The effectiveness of this algorithm was experimentally verified with three different type samples, and the inspection process is completed within max 0.2 second by help of smart camera. It is envisaged that this inspection method for side inspection system of a circular will have a wide application in the future industry.

Auto detect inspection system for single lens product of mobile phone camera (휴대폰 카메라용 렌즈단품 이물 자동검사장비)

  • Song C.H.;Jung Y.W.;Bae S.S.;Song J.Y.;Kim Y.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.432-435
    • /
    • 2005
  • The Mega-pixel camera phones become main trends in mobile phone market. The lens modules used in mesa-pixel camera phones need high resolution. One of the main factors of resolution drop is the defects of bare lens. Though there are many advantages in auto-inspection of defects of bare lens, high technical problems take the defect inspections to be done with manual process. In this paper, the type and the source of defects were described and bare lens defect auto-inspection system design was explained. The designed auto-inspection system is composed of illumination optics part, focusing optics part and auto-moving system. With the proposed auto-inspection system, fast and uniform inspection of bare lens can be achieved.

  • PDF

A Study on the Control Characteristics of Line Scan Light Source for Machine Vision Line Scan Camera (머신 비전 라인 스캔 카메라를 위한 라인 스캔 광원의 제어 특성에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.371-381
    • /
    • 2021
  • A machine vision inspection system consists of a camera, optics, illumination, and image acquisition system. Especially a scanning system has to be made to measure a large inspection area. Therefore, a machine vision line scan camera needs a line scan light source. A line scan light source should have a high light intensity and a uniform intensity distribution. In this paper, an offset calibration and slope calibration methods are introduced to obtain a uniform light intensity profile. Offset calibration method is to remove the deviation of light intensity among channels through adding intensity difference. Slope calibration is to remove variation of light intensity slope according to the control step among channels through multiplying slope difference. We can obtain an improved light intensity profile through applying offset and slope calibration simultaneously. The proposed method can help to obtain clearer image with a high precision in a machine vision inspection system.

Design and Implementation of Green Coastal Lighting System for Entrance to Coastal Pier

  • Jae-Kyung Lee;Jae-Hong Yim
    • Journal of Navigation and Port Research
    • /
    • v.47 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • The hardware of an LED lighting control system for coastal lighting at coastal pier entrance consists of a power supply unit, an AVR control unit, a CLCD output unit, an LED control unit, a scenario selection switch unit, and an operation speed display unit. It is made of an 8-channel. The CPU used ATmega128 and the FET was used to control the current signal. To operate the CPU, DC 12V was converted to DC 5V using a regulator 7805. A heat sink was used to remove heat generated in the FET. By connecting the load LED module to the manufactured 8-channel LED lighting control system, the operation was confirmed through various production scenarios. In addition, a control system was designed to show the most suitable color for the atmosphere of the coastal pier according to the input value of temperature and illumination using a fuzzy control system. Computer simulation was then conducted. Results confirmed that fuzzy control did not need to store many data inputs due to characteristics of artificial intelligence and that it could efficiently represent many output values with simple fuzzy rules.

Optical Design of a Multilayer LED Array Light Source and Illumination Optics for a Large-Screen LC Projection Display System (대화면 액정 화상 투영기용 다층 배열 엘이디 광원 및 조명광학계 설계)

  • Kim, Hyun Hee;Han, Dong Jin;Kim, Jin Seung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.4
    • /
    • pp.226-232
    • /
    • 2015
  • A double-layer LED array together with an illumination optical system is proposed as a possible light source for LC projection display systems for large screens, up to $8m{\times}6m$ (400 inches diagonal). The heat dissipation problem of the LED array is solved by arranging the LEDs in double layers, and thermal analysis shows its effectiveness. The light from the LEDs in the back layer can be transmitted through the front layer without significant loss by arranging the LEDs in non-overlapping positions in the two layers and inserting suitable microlenses between the two layers and holes in the first layer. Together with the double-layer LEDs, an illumination optical system is designed to illuminate liquid crystal panels with good uniformity and appropriate matching with the projection optics.

Implementation of Real-time Interactive Ray Tracing on GPU (GPU 기반의 실시간 인터렉티브 광선추적법 구현)

  • Bae, Sung-Min;Hong, Hyun-Ki
    • Journal of Korea Game Society
    • /
    • v.7 no.3
    • /
    • pp.59-66
    • /
    • 2007
  • Ray tracing is one of the classical global illumination methods to generate a photo-realistic rendering image with various lighting effects such as reflection and refraction. However, there are some restrictions on real-time applications because of its computation load. In order to overcome these limitations, many researches of the ray tracing based on GPU (Graphics Processing Unit) have been presented up to now. In this paper, we implement the ray tracing algorithm by J. Purcell and combine it with two methods in order to improve the rendering performance for interactive applications. First, intersection points of the primary ray are determined efficiently using rasterization on graphics hardware. We then construct the acceleration structure of 3D objects to improve the rendering performance. There are few researches on a detail analysis of improved performance by these considerations in ray tracing rendering. We compare the rendering system with environment mapping based on GPU and implement the wireless remote rendering system. This system is useful for interactive applications such as the realtime composition, augmented reality and virtual reality.

  • PDF

Behavioral Monitoring System for Mud Shrimp Upogebia major and the Photoresponse to Illumination with Different Wavelength LEDs (쏙(Upogebia major)의 광반응 분석시스템 구축과 발광다이오드(Light-Emitting Diode) 파장별 행동분석)

  • Jang, Jun-Chul;Chung, Jong-Kyun;Hur, Youn-Seong;Song, Jae-Hee;Kim, Jong-Myoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.4
    • /
    • pp.413-420
    • /
    • 2017
  • The increase in the number of mud shrimps Upogebia major is a concern because of their negative effects on shellfish aquaculture, including Manila clam Venerupis philippinatum along the west coast of Korea. This study developed a behavioral analysis system for aquatic animals using a set of monochromatic light-emitting diode (LED) modules covering the visible light range at similar intervals. Movements of mud shrimp were monitored using a tracking system under illumination with infra-red light and an LED of 660 nm wavelength without provoking stimulation. The minimum light intensity needed to induce a photoresponse by the mud shrimp was $10{\mu}mole/m^2/s$ under the conditions tested. Of the six kinds of LED illuminations tested, the most sensitive response was obtained with illumination with the 505 nm LED, followed in order by LEDs with peak wavelengths of $525nm{\fallingdotseq}465nm$ > $405nm{\fallingdotseq}590nm$ > 660 nm. These findings should help to identify LED sources that efficiently induce movement of the mud shrimp and also for monitoring movement without stimulating.

A Study on the Effect of Signal Delay in Reduction Technique for Reducing Shading (연집제로구간에서 발생하는 음영현상을 줄이기 위한 기법에서 신호지연이 미치는 영향 연구)

  • Han, Doo-Hee;Lee, Kyu-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.243-249
    • /
    • 2018
  • In this paper, we analyzed the effect of modulation scheme and modulation scheme on the dimming level of visible light communication system and studied the effect of distortion due to delayed signal. Currently, the modulation schemes most commonly used in visible light communication result in increasing the communication performance but reducing the brightness of the entire illumination. Continuous Burst Zero Duration will severely degrade lighting. This degrades not only the illumination but also the performance of the whole system and causes Flicker phenomenon. In this paper, we analyze the relationship between modulation technique and illumination - communication performance and investigate the effect of signal delay on visible light communication system. Through simulation, we analyze the performance of IPI-OOK which has the best communication-lighting performance and propose future research directions accordingly.

Formation of Cross-Linked Products of The Reaction Center D1 Protein in Photosystem II under Light Stress

  • Uchida, Suguru;Kato, Yoji;Yamamoto, Yasusi
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.382-384
    • /
    • 2002
  • When illuminated with strong visible light, the reaction center Dl protein of photo system II is photodamage and degraded. Reactive oxygen species and endogenous cationic radicals generated by photochemical reactions are the cause of the damage to the Dl protein. Recently we found that the photodamaged Dl protein cross-links with the surrounding polypeptides such as D2 and CP43 in photosystem II. As the cross-linking reaction is dependent on the presence of oxygen, reactive oxygen species are suggested to be involved. Among the reactive oxygen species examined, ? OH was most effective in the formation of the cross-linked products. These results indicate that the cross-linking is mostly due to ? OH generated at photosystem II. The cross-linking site of the Dl protein is not known. As several tyrosine residues exist at the D­E loop of the Dl protein, there is a possibility that di-Tyr is formed between the D­E loop of the Dl protein and surrounding polypeptides during the strong illumination. Therefore, we examined the formation of di-Tyr using the monoclonal antibody against di-Tyr under excess illumination of the photosystem II membranes. The results obtained here suggest that no di-Tyr is formed during the excess illumination of photosystem II.

  • PDF

A Luminous Environment of Outdoor Spaces in Apartment Complexes (아파트 단지(團地) 외부공간(外部空間)의 빛 환경(環境)에 관(關)한 연구(硏究))

  • Kwon, So-Young;Ha, Mi-Kyoung;Lee, Hyo-Chang
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.237-241
    • /
    • 2006
  • The Qualitative improvements of outdoor spaces are unsatisfactory in comparison with that of indoor environment in existing apartments. Lately construction companies are differentiating the outdoor spaces of apartment complexes to meet needs of residents. However, high-rise buildings inherently have limitations on providing exposure to the outdoor settings and inappropriate lightings could have serious impacts on physical and psychological health of residents. Therefore, the purpose of this study is to provide useful information for the luminous environment of outdoor spaces through the analysis of current apartment complexes' lighting plans. Outdoor space of branded apartment complexes in Seoul, built after the year 2003, were researched. Through site visits, illumination level and lighting plans were investigated classified into entry area, passage area, plaza, rest area, exercise area, and play area. With the result, illumination level of apartment complexes researched was lower than KS illumination standard in all areas and the lighting plans were mostly shown in different condition of first intended lighting plan because of insufficiency of maintenance in lighting system. Therefore, it is need to provide better luminous environment to make outdoor space more lively and energetic at the night time.

  • PDF