• Title/Summary/Keyword: Illumination measurement

Search Result 234, Processing Time 0.024 seconds

Measurement of Flow Field in a Domestic Hot-Water Pump by PIV (PIV에 의한 가정용 온수펌프의 유동장 계측)

  • Lee, H.;Im, Y. C.;Kim, J. H.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

Luminance Analysis of the Apartment Exterior Lighting using HDR Images (HDR이미지를 이용한 공동주택 외부조명의 휘도 분석)

  • Hong, Sung-De;Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

A Study on the Environmental Improvement in the Interior Construction Fields with the check-list (실내건축의 작업환경 개선을 위한 기본적 관리방안에 관한 연구)

  • 이용의
    • Korean Institute of Interior Design Journal
    • /
    • no.9
    • /
    • pp.10-17
    • /
    • 1996
  • With the ever-increasing important of high-speed information in society as we move towards the 21 st century. Interior design and it's working condition has been changed a great deal included a sort of each special character and make a difference against the others. It used to be find a great poles asunder of worker's safety and project quality according to the environmental dimension of interior construction field as if they should be a pleasantness or poor condition. This research aimed to improvement of environmental construction field of interior with construction engineers and particular interior labors in 4 phases as : ⅠThe preparatory phase : -Secure a Budget, Environmental safety supervisor -Fix of Design quality, Construction period. -Choice of Construction method, Sub constructing Ⅱ. Starting work phase ; -Capacity , Safety of temporary power line. -Carriage, Stock of Material -Safety of Electronic tools, -Personal protector. Ⅲ. Working period ; -Ventilation, I illumination of working place. -Measurement of environmental working condition Ⅳ.Finish working phase ; -Analysis of measurement data. -Evaluation and making up for the weak point. -Keeping data.

  • PDF

Image Processing for Video Images of Buoy Motion

  • Kim, Baeck-Oon;Cho, Hong-Yeon
    • Ocean Science Journal
    • /
    • v.40 no.4
    • /
    • pp.213-220
    • /
    • 2005
  • In this paper, image processing technique that reduces video images of buoy motion to yield time series of image coordinates of buoy objects will be investigated. The buoy motion images are noisy due to time-varying brightness as well as non-uniform background illumination. The occurrence of boats, wakes, and wind-induced white caps interferes significantly in recognition of buoy objects. Thus, semi-automated procedures consisting of object recognition and image measurement aspects will be conducted. These offer more satisfactory results than a manual process. Spectral analysis shows that the image coordinates of buoy objects represent wave motion well, indicating its usefulness in the analysis of wave characteristics.

The Improved Joint Bayesian Method for Person Re-identification Across Different Camera

  • Hou, Ligang;Guo, Yingqiang;Cao, Jiangtao
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.785-796
    • /
    • 2019
  • Due to the view point, illumination, personal gait and other background situation, person re-identification across cameras has been a challenging task in video surveillance area. In order to address the problem, a novel method called Joint Bayesian across different cameras for person re-identification (JBR) is proposed. Motivated by the superior measurement ability of Joint Bayesian, a set of Joint Bayesian matrices is obtained by learning with different camera pairs. With the global Joint Bayesian matrix, the proposed method combines the characteristics of multi-camera shooting and person re-identification. Then this method can improve the calculation precision of the similarity between two individuals by learning the transition between two cameras. For investigating the proposed method, it is implemented on two compare large-scale re-ID datasets, the Market-1501 and DukeMTMC-reID. The RANK-1 accuracy significantly increases about 3% and 4%, and the maximum a posterior (MAP) improves about 1% and 4%, respectively.

A study on the cutting surface roughness measurement by image processing (이미지프로세싱을 이용한 가공면의 표면거칠기 측정에 관한 연구)

  • So, Eui-Yearl;Im, young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.124-133
    • /
    • 1994
  • Many of non-contact measuring systems are used to estimate surface characteristics owing to their advantages of high speed and undanaged test. In this paper, a new measuring system is proposed to acquire image from CCD camera through back light illumination. Lowpass filter is very useful in view of noise removal and optimum binary image can be made through histogram equalization which is one of the histogram technique to maximize brightness intensity between workpiece and background. Laplacian operator is used to detect workpiece edge from binary image. In case of image treatment applying Laplacian operator, surface roughness is calculated by introducing conversion coefficient for coordinate of pixel which edge is composed of. In summary, the work is concerned with the development of a new technique for roughness measurement by the image processing in turning.

  • PDF

An Efficient Algorithm for 3-D Range Measurement using Disparity of Stereoscopic Camera (스테레오 카메라의 양안 시차를 이용한 거리 계측의 고속 연산 알고리즘)

  • 김재한
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1163-1168
    • /
    • 2001
  • The ranging systems measure range data in three-dimensional coordinate from target surface. These non-contact remote ranging systems is widely used in various automation applications, including military equipment, construction field, navigation, inspection, assembly, and robot vision. The active ranging systems using time of flight technique or light pattern illumination technique are complex and expensive, the passive systems based on stereo or focusing principle are time-consuming. The proposed algorithm, that is based on cross correlation of projection profile of vertical edge, provides advantages of fast and simple operation in the range acquisition. The results of experiment show the effectiveness of the proposed algorithm.

  • PDF

The Characteristics of the Particle Position Along an Optical Axis in Particle Holography (입자 홀로그래피에서 입자의 광축 방향 위치 특성에 관한 연구)

  • Choo Yeon-Jun;Kang Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.287-297
    • /
    • 2006
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. One of inherent limitations of particle holography is the very long depth of field of particle images, which causes considerable difficulty in the determination of particle positions in the optical axis. In this study, we introduced three auto-focusing parameters corresponding to the size of particles, namely, Correlation Coefficient, Sharpness Index, and Depth Intensity to determine the focal plane of a particle along the optical axis. To investigate the suitability of the above parameters, the plane image of dot array screens containing different size of dots was recorded by diffused illumination holography and the positions of each dot in the optical axis were evaluated. In addition, the effect of particle position from the holographic film was examined by changing the distance of the screen from the holographic film. All measurement results verified that the evaluated positions using suggested auto-focusing parameters remain within acceptable range of errors. These research results may provide fundamental information for the development of the holographic velocimetry system based on the automatic image processing.

Vicarious Calibration-based Robust Spectrum Measurement for Spectral Libraries Using a Hyperspectral Imaging System

  • Chi, Junhwa
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.4
    • /
    • pp.649-659
    • /
    • 2018
  • The aim of this study is to develop a protocol for obtaining spectral signals that are robust to varying lighting conditions, which are often found in the Polar regions, for creating a spectral library specific to those regions. Because hyperspectral image (HSI)-derived spectra are collected on the same scale as images, they can be directly associated with image data. However, it is challenging to find precise and robust spectra that can be used for a spectral library from images taken under different lighting conditions. Hence, this study proposes a new radiometric calibration protocol that incorporates radiometric targets with a traditional vicarious calibration approach to solve issues in image-based spectrum measurements. HSIs obtained by the proposed method under different illumination levels are visually uniform and do not include any artifacts such as stripes or random noise. The extracted spectra capture spectral characteristics such as reflectance curve shapes and absorption features better than those that have not been calibrated. The results are also validated quantitatively. The calibrated spectra are shown to be very robust to varying lighting conditions and hence are suitable for a spectral library specific to the Polar regions.

A Study on Strobe Control over LED Lighting System for Machine Vision (머신비전을 위한 LED 조명시스템의 스트로브 제어 구동에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.121-125
    • /
    • 2021
  • The machine vision technology has been widely used in the industrialized nations like the United States, Japan, and EU in the various industries from the late 1980s. Machine vision inspection system mainly consists of a camera, optics, illumination and an image acquisition system. Optimization of the illumination light source is very important. This paper shows a comparison between Pulse Width Modulation (PWM) control and strobe control in driving LED lighting system for machine vision. PWM control method has problems such as a temperature rising of LED and a flickering in image measurement for inspection. In contrast, the proposed strobe control method can suppress the temperature of LED light source below 40℃. Also, it can remove the flickering problem through a synchronization between a frame grabber and a camera shutter. Finally, the strobe control method was shown to extract clearer images with a high precision compared to PWM control method.