• Title/Summary/Keyword: Ignition possibility

Search Result 94, Processing Time 0.028 seconds

A Fundamental Study on the Properties of Cement Collected at Different Process Line (시멘트 분쇄공정별 물성에 관한 기초적 연구)

  • Kim, Jong-Back;Cha, Wan-Ho;Kwon, O-Bong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.111-114
    • /
    • 2006
  • This paper is to investigate the chemical composition and physical properties of cements collected at different crushing process line of ordinary portland cement to verify the possibility for producing special purpose cement based on the particle distribution technique. According to test results, six different cement samples with different blaine were gathered. loss on ignition and chemical composition of cements gathered were satisfied with KS L 5201. Cement collected at line 5 had the lowest blaine value while cement at line 4 had the highest blaine value. The coarser the cement particle is, the larger the fluidity of cement is. The compressive strength of cement was highly affected by the blaine value of cement. It is confirmed that the use of cement produced by the process of particle distribution control may be applied for special purpose cement without modification of chemical composition.

  • PDF

Fire Characteristics of Composites for Interior Panels Using Cone calorimeter (콘칼로리미터를 이용한 내장판용 복합재료의 화재특성)

  • 이철규;정우성;이덕희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • Composite materials were used widely due to merit of light weight, low maintenance cost and easy installation. But it is the cause of enormous casualties to men and properties because of weak about the fire. Particularly, it is more serious in case of subway train installed composite materials. For this reason, experimental comparison has been done fur measuring heat release rate(H.R.R) and smoke production rate(S.P.R) of interior panels of electric motor car using cone calorimeter. A high radiative heat flux of 50kW/㎡ was used to bum out all materials and to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were dependent on the kinds of the interior materials. From the heat release rate curves, the sustained ignition time, peak heat release rate and total heat release rate were deduced, These data are useful in classifying the materials by calculating two parameters describing the possibility to flashover.

A Study of the analysis on the risk of ignition and low-temperature burns caused by the use of electrically heated clothes (발열의류로 인한 화재위험성 및 저온화상에 대한 분석 연구)

  • Lee, Jeong-Il
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.122-129
    • /
    • 2018
  • Purpose : This study aims to seek out the risk of low-temperature burns and fire. Method : Hot vests are connected by higher voltage than walking voltage. Results : Accordingly, the possibility of low-temperature burns and fire was proved high. It was also shown that hot vests with relatively lower resistance on heat rays reached a higher temperature as the same voltage was applied. Conclusion : There are some problems with hot vests because they do not have any safety devices like a thermostat or a timer to prevent temperature increasing rapidly. For the purpose of reducing the risk of low-temperature burns and fire, setting the standard of the minimum resistance temperature and regulating the use of heat rays with lower resistance are necessary.

Availability Review of Tailings from the Sangdong Tungsten Mine as a Material for Construction (건설용 재료로서 상동광산광미의 활용성 검토)

  • Kim, Yong-Jic;Kim, Young-Jin;Choi, Yun-Wang;Kim, Sang-Chel
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • This study has focused on the possibility for recycling tailings from the Sangdong tungsten mine (TA) as admixture for concrete. TA has been accumulating for several decades in Sangdong, a region in Korea, and there is a growing demand for alternative uses for this hazardous substance. In particular, the use must be in accordance with the hazardous materials stipulations under the Korean waste control act. This study showed that TA presented pH of 8.0-9.3, 18.7-22.0% of water content, 2.7% of maximum ignition loss. The chemical composition of TA showed minute differences from each depth of sampling that represented approximately 50% of $SiO_2$ and 13% of both $Al_2O_3$ and $Fe_2O_3$. The chemical composition of Cd, Cu, Zn and Pb from mortar incorporating TA showed lower levels of hazardous materials which met the specifications of the waste control act in Korea. The TA mortar also appeared very effective for stabilizing/solidifying heavy metals particularly when used in conjunction with SG.

A Study on the Effect of Compression Ratio and EGR on the Partial Premixed Diesel Compressed Ignition Combustion Engine Applied with the Split Injection Method (2단 분사방식을 적용한 부분 예혼합 디젤압축착화연소엔진의 성능에 미치는 압축비 및 EGR의 영향)

  • Chung, Jae-Woo;Kang, Jung-Ho;Lee, Sung-Man;Kang, Woo;Kim, Byoung-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.32-38
    • /
    • 2006
  • Currently, due to the serious world-wide air pollution by substances emitted from vehicles, emission control is enforced more firmly and it is expected that the regulation requirements for emission will become more severe. A new concept combustion technology that can reduce the NOx and PM in relation to combustion is urgently required. Due to such social requirement, technologically advanced countries are making efforts to develop an environment-friendly vehicle engine at the nation-wide level in order to respond to the reinforced emission control. As a core combustion technology among new combustion technologies for the next generation engine, the homogenous charge compression ignition(HCCI) is expanding its application range by adopting multiple combustion mode, catalyst, direct fuel injection and partially premixed combustion. This study used a 2-staged injection method in order to apply the HCCI combustion method without significantly altering engine specifications in the aspect of multiple combustion mode and practicality by referring to the results of studies on the HCCI engine. In addition, this study confirmed the possibility of securing optimum fuel economy emission reduction in the IMEP 8bar range(which could not be achieved with existing partially premixed combustion) through forced charging, exhaust gas recirculation(EGR), compression ratio change and application of DOC catalyst.

A Study on Combustion and Exhaust Emission in Direct Injection Diesel Engine (직접분사식 디젤기관의 연소 및 배기에 관한 연구)

  • Kim, Du-Beom;Kim, Gi-Bok;Kim, Chi-Won;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • Recently the direct injection diesel engine is the most efficient one available for road vehicles, so this fundamental advantage suggests the compression injection diesel engine are a wise choice for future development efforts. The compression ignition diesel engine, with its bigger compression ratios if compared to the SI engine, offers a higher thermodynamic efficiency, also additionally the diesel engine with its less pumping losses due to the throttled intake charge as in a SI engine has higher fuel economy. But the largest obstacle to the success of this engine is meeting emission standards for Nitric oxides and particulate matter while maintain fuel consumption advantage over currently available engines. Thus its use should be largely promoted, however, diesel engine emits more Nitric oxides and particulate matter than other competing one. There has been a trade-off between PM and NOx, so efforts to reduce NOx have increased PM and vice versa, but trap change this situation and better possibility emerge for treating NOx emission with engine related means, such as injection timing, equivalence ratio, charge composition, and engine speed. The common rail direct injection system is able to adjust the fuel injection timing in a compression ignition engine, so this electronically controlled injection system can reduce the formation of NOx gas without increase in soot. In this study it is designed and used the engine test bed which is installed with turbocharge and intercooler. In addition to equipped using CRDI by controlling injection timing with mapping modulator, it has been tested and analyzed the engine performance, combustion characteristics, and exhaust emission as operating parameters.

Analysis of Sensitivity, Correlation Coefficient and PCA of Input and Output Parameters using Fire Modeling (화재모델링을 이용한 입출력 변수의 민감도, 상관계수 분석과 주성분 분석)

  • Nam, Gi Tae;Kim, Jeong Jin;Yoon, Seok Pyo;Kim, Jun Kyoung
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.46-54
    • /
    • 2019
  • Even though the fire performance-based design concept has been introduced for various structures and buildings, which have their own specific fire performance level, the uncertainties of input parameters always exist and, then, could reduce significantly the reliability of the fire modeling. Sensitivity analysis was performed with three limited input parameters, HRRPUA, type of combustible materials, and mesh size, which are significantly important for fire modeling. The output variables are limited to the maximum HRR, the time reaching the reference temperature($60^{\circ}C$), and that to reach limited visible distance(5 m). In addition, correlation coefficient analysis was attempted to analyze qualitatively and quantitatively the degree of relation between input and output variables above. Finally, the relationship among the three variables is also analyzed by the principal component analysis (PCA) to systematically analyze the input data bias. Sensitivity analysis showed that the type of combustible materials is more sensitive to maximum HRR than the ignition source and mesh size. However, the heat release parameter of the ignition source(HRR) is shown to be much more sensitive than the combustible material types and mesh size to both time to reach the reference temperature and that to reach the critical visible distance. Since the derived results can not exclude the possibility that there is a dependency on the fire model applied in this study, it is necessary to generalize and standardize the results of this study for the fire models such as various buildings and structures.

A Study on Performance Characteristics of a Small-Sized Hydrogen-Fuelled Two-Stroke Engine (수소 연료를 적용한 소형 2행정 엔진 성능 특성에 관한 연구)

  • Kim, Yongrae;Kim, Seonyoeb;Oh, Sechul;Park, Cheolwoong;Choi, Young
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.28-33
    • /
    • 2020
  • In this study the possibility of hydrogen as a fuel in a small-sized two-stroke SI (Spark ignition) engine was investigated. For this purpose, experimental setup including an engine, a dynamometer, equipments for hydrogen and lubricant oil supply was prepared. And then preliminary experiments for the hydrogen-fueled engine combustion were conducted. In the case of hydrogen-fueled engines comparing to gasoline backfire occurs when the excess air ratio is lower than a specific value. This can cause engine power reduction and damage to the engine parts. The engine was controlled to operate at lean conditions to prevent backfire. Through the control of excess air ratio, the maximum engine brake power output of 3 kW was achieved in a 210 cc engine, while it was 6 kW in case of gasoline fuel.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.

Eutrophication in the Namhae Coastal Sea 2. The Aspects of Eutrophication of Bottom Mud and Surface Seawater in the Namhae Coastal Seas (남해 연안해역의 부영양화 2. 남해 연안해역의 저질 및 수질의 부영양화 실태)

  • Kim, Sung-Jae
    • Journal of Wetlands Research
    • /
    • v.3 no.2
    • /
    • pp.107-118
    • /
    • 2001
  • The aim of this paper is to grasp eutrophication aspects in Namhae coastal seas, statistically analyzing existing data for their surface seawater and bottom mud. A pollution level(ignition loess) of bottom mud, on the whole, trended to increase as moving the coastal sea around Mokpo-Wando toward the east(Gyeongnam Namhae coastal seas). Especially, the pollution level(ignition loss=10.5%) of bottom mud for the coastal sea around Tongyeong-Keoje-Gosung was similar to that(10.3%) for the coastal sea around Masan-Jinhae, whose coastal marine pollution was the severest in Namhae coastal seas. It indicates that large amounts of pollutant from aqualculture facilities have been, thus far, accumulated on the coastal sea around Tongyeong-Keoje-Gosung, considering there was no significant inflow of sewage and industrial wastewater into this coastal sea. A COD, T-N, and T-P level of surface seawater, on the whole trended to increase as moving the coastal sea around Mokpo-Wando toward the east(Gyeongnam Namhae coastal seas). A COD level appeared to be the second grade of coastal water quality over the entire year throughout all Namhae coastal seas A T-N level exceeded the third grade of coastal water quality throughout all Namhae coastal seas except the coastal sea around Mokpo-Wando. Especially, a T-N level exceeded as many as three and six times over the third grade of coastal water quality in the coastal sea around Tongyeong-Keoje-Gosung and Masan-Jinhae, respectively. A T-P level appeared to be the second grade of coastal water quality in the coastal sea around Mokpo-Wando and the third grade of coastal water quality in the coastal sea around Yosu-Narnhae and Tongyeong-Keoje-Gosung, while it exceeded as many as two times over the third grade of coastal water quality. A degree of eutrophication of the surface seawater was 1.5 in the coastal sea around Mokpo-Wando and 11.9 In the coastal sea around Tongyeong-Keoje-Gosung, gradually increasing as moving toward the east(Gyeongnam Narnhae coastal seas). It sharply increased to 146.1 in the coastal sea around Masan-Jinhae. Because the degree of eutrophication throughout all Namhae coastal seas exceeded 1, a red tide organism could pose a possibility of proliferation at any place of Namhae coastal seas if other requirements were satisfied. It indicates that a red tide may move to another place once a red tide breaks out at a place of Namhae coastal seas.

  • PDF