• 제목/요약/키워드: Ice cooling

검색결과 228건 처리시간 0.036초

얼음과 냉각수를 이용한 콘크리트의 프리쿨링에 관한 연구 (Study on Precooling of Concrete Using Ice and Cooling Water)

  • 정철헌;박장호;이순환
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2000
  • Crack control due to temperature is an important factor for the mass concrete structure. Pre-cooling is the effective system to reduce the highest temperature of mass concrete. In this study, for pre-cooling, cooling water, cooling water with ics flake are used. The results of a series of experimental studies indicate that the changes in properties of fresh concrete after cooling are of low degree, and compressive strength of concrete is changed very little by cooling. The adiabatic temperature rise is also measured with pre-cooling concrete specimens. It is shown that hydration heat characteristics of cement and concrete were largely affected by pre-cooling.

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

건물용 열병합발전 설비를 중심으로 한 종합 에너지 시스템의 최적 일간 운전모형 수립에 관한 연구 (A Study on Daily Operation Model for Total Energy System Including Building Cogeneration, Ice Storage, Thermal and Electrical Storage Facilities)

  • 박종성;장승찬;심건보;김정훈;고요
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.724-726
    • /
    • 1996
  • In this paper, we propose an optimal daily operation model for the total energy system which includes cogeneration, thermal storage and electrical charger and ice storage facilities. Storing and utilizing the surplus thermal and electrical energy, the daily operation cost could be reduced and more efficient use of thermal energy could be achieved. The ice storage cooling system has a merit of reduce the electricity cost by time of day rate(peak/off-peak). And also, refrigerator can be down sized compare to the other cooling system From this model, operation costs of the sample cogeneration system with/without auxiliary facilities are obtained and compared to each other. In case study, the sensitivity of operating cost is simulated according to the variation of cogeneration production cost, electricity rate, etc.

  • PDF

a해산어의 부분동결에 의한 $Ca^{2+}\;및\;Mg^{2+}$ -dependent Adenosin Triphosphatase 활성 및 근섬유의 미세구조 변화 III. 저온저장 과정중 방어 근육조직의 미세구조의 변화 (Changes in the $Ca^{2+}\;and\;Mg^{2+}$ - dependent Adenosine Triphosphatase Activity and Ultrastructure of Marine Fishes by Partial Freezing III. Changes in the Ultrastructure of Muscle Tissues of Yellowtail during Low-temperature Preservation)

  • 최경호;박찬성
    • 한국식품영양과학회지
    • /
    • 제20권6호
    • /
    • pp.629-636
    • /
    • 1991
  • 방어를 공시어로 하여 빙장($0^{\circ}C$), PF저장($-3^{\circ}C$) 및 동결저장($-20^{\circ}C$)하면서 자장과정중 일어나는 근육 조직의 변화를 현미경적으로 관찰하여 다음과 같은 결과를 얻었다. 빙장의 경우에는 저장 3일째에 glycogen이 소실되고 mitochondria 내막이 퇴행되었으며 근원섬유도 절단되었다. 근원섬유의 절단면은 동근 형태를 나타내었다. PF저장시에도 glycogen이 소실되고 mitochondria가 퇴행되었으나 그 정도는 빙장에 비하여 경미하였다. 저장 3일째에 빙결정이 생성되어 저장기간이 길어질수록 크기와 숫자가 증가되었으나 빙결정의 모양이 둥근 모습이었으며 주된 생성부위가 섬유속 사이로서 myofibril의 손상은 경미하였다. 동결저장시에는 저장 14일까지 glycogen입자가 관찰 되었고 mitochondria도 내막구조를 유지하였으나 저장 3일째부터 섬유속 내부에까지 빙결정이 생성되었으며 이로 인하여 myofibril이 손상되었다. 절단된 섬유속의 선단은 빙장의 경우와는 달리 불규칙한 모습이었다. 이상의 결과로부터 PF저장법이 단기간(약 2주)의 생선저장에는 빙장에 비하여 효소활성이 억제되고 동결저장에 비하여 빙결정에 의한 myofibril의 손상이 적은 효과적인 방법으로 판정되었다.

  • PDF

인버터구동 모터펌프를 이용한 아이스 슬러리형 빙축열시스템 전유량제어 운전시험 (Laboratory Test on Total Flow Control for Ice Slurry System with Inverter Fed Motor Pump)

  • 최병윤;이경호;이상렬;이학주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.260-265
    • /
    • 2001
  • This paper describes total flow control of an ice slurry system for pump energy saving. Similar turbo machinery has a characteristic that input power ratio is proportional to the three time of revolution speed ratio. To reduce the energy cost of brine pump in ice slurry storage systems, inverter is adapted instead of 3-way valve to control the speed of brine pump motor. One type of cooling load profile was used as driving load of the system, generated by a boiler and warm water storage tank. As results of the laboratory test, energy consumption and cost of the pump were reduced by 11.4%.

  • PDF

흰쥐의 적출된 작업성 심장에서 허혈성 심정지시 국소냉각법이 심근보호에 미치는 영향 (Effect of Topical Hypothermia on Myocardial Protection from Ischemia - Experimental study using isolated rat heart perfusion technique-)

  • 최종범
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.231-239
    • /
    • 1988
  • Currently numerous methods are in use for myocardial hypothermia as a myocardial preservation modality for cardiac operation. During cardiac ischemia after crystalloid cardioplegia[4C GIK solution], topical cold saline[Group I, a=9], topical ice slush[Group II, n=9] and topical ice chip[Group III, a=10] have been compared for myocardial surface cooling in the isolated rat heart model of cardiopulmonary bypass. During postischemic period, hemodynamic functions[aortic flow, coronary flow, peak aortic pressure and heart rate], biochemical enzymatic activities and cellular injuries with electron microscope were evaluated in this isolated rat heart perfusion model. Postischemic aortic flow, cardiac output and peak aortic pressure in Group I and Group II recovered better than Group III.[p< 0.05] Postischemic creatine kinase and lactate dehydrogenase leakages in Group II and Group III increased more than Group l and postischemic mitochondrial swelling in Group III was more severe than Group I, and Group II.[p< 0.05] These results suggest that topical cold saline was the better method than topical ice slush or topical ice chip as a myocardial preservation modality in the isolated rat heart model of cardiopulmonary bypass.

  • PDF

온.냉적용시 신체부위별 및 시간에 따른 체온변화에 대한 연구 (A Study about Change in the Temperature by Each Region and Time After Hot & Cold Application)

  • 김근조;이규리
    • 대한물리치료과학회지
    • /
    • 제2권3호
    • /
    • pp.577-586
    • /
    • 1995
  • This paper was the study of a change in the body temperature of each region(Oral cavity, Axillary, Cubital, Popliteal, Inguinal region)and by time after appling hot(Hot Pack, Infra Red) and cold (Ice Pack, Cooling Pack) to lumbar region. The statistical measures were sampled through 16 senior students in dept. of Physiothrapy, Kim Cheun College and the period for this was from July 13, 1995 to July 20, 1995. There was an increse in the temperature of distal portion besides application area after hot application. The increse in the body temperature according to applied agents and time showed significance statistically(p<0.01, p<0.05). There was just a decrease in the temperature of distal portions besides application area after appling Ice Pack. Furthermore there was an increase in the body temperature after appling Cooling Towel. Therefore, during cold application the appling agents and time did not showed any significance statistically.

  • PDF

해수 냉방시스템의 빙상경기장 적용 방안 및 LCC 분석 (Application and Life Cycle Cost Analysis for Ice-rink using Seawater Heat Source Cooling System)

  • 박진영;김삼열;이호생;김현주
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.50-55
    • /
    • 2013
  • On a plan for the Winter Olympics 2018, Korean government is in the process of the world's first use of ocean energy for the Olympic ice-rink. This technology will be applied to a seaside town and have possibility of an export industry. In this study, we researched facilities and system for P ice-rink that acts as a cultural center as well as a physical plant in Busan and provided the way that apply by seawater heat source. Also, existing system and seawater heat source system of P ice-rink was analyzed by the most commonly used life cycle cost analysis among economics methods. Such economics data for ice-rink using seawater will be utilized by a basic information.