• 제목/요약/키워드: ITS test

검색결과 14,310건 처리시간 0.046초

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.400-406
    • /
    • 2010
  • This paper deals with parameter tuning of the Power System Stabilizer (PSS) for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations.

Kolmogorov-Smirnov Type Test for Change with Sample Fourier Coefficients

  • Kim, Jae-Hee
    • Journal of the Korean Statistical Society
    • /
    • 제25권1호
    • /
    • pp.123-131
    • /
    • 1996
  • The problerm of testing for a constant mean is considered. A Kolmogorov-Smirnov type test using the sample Fourier coefficients is suggested and its asymptotic distribution is derived. A simulation study shows that the proposed test is more powerful than the cusum type test when there is more than one change-point or there is a cyclic change.

  • PDF

TRNG (순수 난수 발생기)의 테스트 기법 연구 (Test Methods of a TRNG (True Random Number Generator))

  • 문상국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.803-806
    • /
    • 2007
  • TRNG (True Random Number Generator)를 테스트 하는 방법은 PRNG (Pseudo Random Number Generator)나 산술연산기를 비롯한 결정적 (deterministic) 소자에 대한 테스트와는 많이 틀려서, 새로운 개념과 방법론이 제시되어야 한다. 하드웨어적으로 결정적인 소자들은 패턴을 사용한 테스트 (ATPG; automatic test pattern generation)에 의해 커버가 될 수 있지만, 순수 난수는 발생 결과의 아날로그적인 특성에 의하여 자동 패턴 생성 방식에 의해 소자를 테스트하기가 불가능하다. 본 논문에서는 하드웨어와 소프트웨어를 결합한 테스트 방식으로 테스트 패턴에 연속적인 패턴의 변화를 주면서 통계적으로 관찰하는 방식인 Diehard test라는 테스트 방식을 연구, 분석하고, 순수 난수의 테스트 시 고려해야 할 주안점을 제안한다.

  • PDF

미국과 유럽의 풍력터빈 풍동실험 (Wind tunnel test of wind turbine in United States and Europe)

  • 장병희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.42-46
    • /
    • 2005
  • In spite of fast growing of prediction codes, there is still not negligible uncertainty in their results. This uncertainty affects on the turbine structural design and power production prediction. With the growing size of wind turbine, reducing this uncertainty is becoming one of critical issues for high performance and efficient wind turbine design. In this respect, there are international efforts to evaluate and tune prediction codes of wind turbine. As the reference data for this purpose, field test data is not appropriate because of its uncontrollable wind characteristics and its inherent uncertainty. Wind tunnel can provide controllable wind. For this reason, NREL has done the full scale test of the 10m turbine at NASA-Ames. With this reference data, a blind comparison has been done with participation of 18 organizations with 19 modeling tools. The results were not favorable. In Europe, a similar project is going on. Nine organizations from five countries are participating in the MEXICO project to do full scale wind tunnel tests and calculation with prediction codes. In this study. these two projects were reviewed in respect of wind tunnel test and its contribution. As a conclusion, it is suggested that scale model wind tunnel tests can be a complementary tool to calculation codes which were evaluated worse than expected.

  • PDF

Aging Effect of Bio-inspired Artificial Basilar Membrane with Piezoelectric PVDF Thin Film

  • Kim, Wan Doo;Park, Su A;Kim, Sang Won;Kwak, Jun-Hyuk;Jung, Young Do;Hur, Shin
    • Elastomers and Composites
    • /
    • 제50권4호
    • /
    • pp.292-296
    • /
    • 2015
  • Biomimetic artificial basilar membrane being a core part of artificial cochlear requires performance evaluation through aging test. To evaluate the aging properties of PVDF piezoelectric membrane used for artificial basilar membrane, its mechanical properties such as tensile strength and elastic modulus and piezoelectric property such as piezoelectric constant were measured. The aging test conditions and acceleration constants were calculated based on Arrhenius model. The changes in tensile strengths and elastic moduli measured were less than 10~20% after aging test equivalent for 10 years. The piezoelectric constants were decreased drastically to 80% of its initial value in the early stage of the aging test and expected to decrease slowly down to 65% over 10 years. The experimental results show the reliability of totally implantable novel artificial cochlear and will contribute its commercialization.

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.

국내도로 주행 시험을 통한 6축 진동시험 방법에 관한 연구 (Multi-axial Vibration Test on MAST System with Field Data)

  • 김찬중;배철용;이봉현;권성진;나병철
    • 한국소음진동공학회논문집
    • /
    • 제16권7호
    • /
    • pp.704-711
    • /
    • 2006
  • Vibration test on MAST(multi axial simulation table) system has several advantage over one-axial vibration test that could simulate 6-DOF, 3-axial translation and 3-axial moment, at the same time. Since field vibration motion can be fully represented with 6-DOF, multi-axial vibration test on vehicle component is widely conducted in technical leading companies to make sure its fatigue performance in vibration environment. On the way to fulfill the process, editing technique of obtained field data is key issue to success a reliable vibration testing with MAST system. Since the original signals are not only too large to fulfill it directly, but all of the measured data is not guarantee its convergency on generating its driving files, editing technique of the original signals are highly required to make some events that should meet the equal fatigue damage on the target component In this paper, key technique on editing a field data feasible for MAST system is described based on energy method in vibration fatigue. To explain its technique explicitly, author first introduced a process on field data acquisition of two vehicle component and then, representing events are produced to keep up with the editing strategy about a energy method. In the final chapter, a time information regarding a vibration test on MAST system is derived from the energy data which is critical information to perform a vibration test.

검증위성 시스템레벨 전자기파(EMC) 시험 및 결과에 대한 분석 (KoDSat System Level EMC(Electro Magnetic Compatibility) Test and an Analysis of the Test Results)

  • 서민석;박석준;심은섭;김세연;채장수
    • 한국항공우주학회지
    • /
    • 제34권4호
    • /
    • pp.102-109
    • /
    • 2006
  • 본 논문에서는 검증위성(KoDSat)의 시스템 레벨 전자기파(EMC) 환경시험 및 전자기파(EMC) 규격을 초과한 시험결과에 대해서 발사체에 대한 영향성 분석 및 하드웨어 개선 방법에 대하여 논하고, EMC2000 소프트웨어 해석을 통해 KSLV-1 발사체의 비행종단시스템(FTS : Flight Termination System)에 영향을 줄 수 있는 검증위성의 전자기파 노이즈원을 도출하였다. 또한 도출된 전자기파(EMC) 노이즈원은 EMI 필터, 접지, 쉴딩(Shielding) 처리 기법을 데이터획득장치(DAU) 전력보드(Power Board)에 적용하여 미약한 값으로 제거되었다. 그리고 이와 같은 일련의 분석과정에 의해 새로 설계된 전력보드는 검증차원에서 데이터획득장치(DAU)에 장착되어 박스자체 전자기파(EMC) 시험 및 최종 2차 검증위성 시스템 레벨 전자기파 시험을 통해 확인되었고, 측정 결과는 저주파대역과 UHF 주파수대역(430Mhz)에서 만족할 만한 감쇄레벨 값을 나타내었다.

정보시스템 성과평가를 위한 형성적 구성변수(Constructs) 및 측정지표 개발 (Development of Formative Constructs and Measurements for Performance Evaluation of Information Systems)

  • 김상훈;김창규
    • 한국IT서비스학회지
    • /
    • 제11권4호
    • /
    • pp.135-151
    • /
    • 2012
  • Traditionally in IS studies, the relationship between construct and its measurement items tends to be assumed to be reflective, meaning that the measurements are a reflection of the construct. In reality, however, the nature of the construct can be often formative, which means that its measurement items describe and define the construct rather than vice versa. The purpose of this study was to investigate theoretical and empirically-analysed differences between formative construct and reflective construct through comprehensive interdisciplinary literature review. And then on the basis of these differences, we intended to derive the rule of specifying whether the construct is formative or reflective and propose the methodology of testing the validity(content validity, construct validity, internal consistency and external construct) of formative construct and its measurements, differentiated from that in the case of reflective construct. Also, we suggested the concrete statistical testing methods such as VTT(Vanishing Tetrad Test), MIMIC(Multiple Indicators and Multiple Causes) test and multi-collinearity test. In order to examine the applicability of this methodology to developing the constructs for performance evaluation of IS(Information Systems), we tried to identify its attribute(formative or reflective) and test the validity for the construct arbitrarily chosen among them which had been derived in our previous IS performance evaluation study by using this methodology. The result of the examination was that the methodology proposed in this study was significantly valid and effective in the area of IS performance evaluation.